-- INFINERA-TP-NCTGIGE-MIB
|
||||
--
|
||||
-- October 2008, Sharfuddin Syed / Narendra Gupta
|
||||
--
|
||||
--
|
||||
-- Copyright (c) 2008-2012 by Infinera Inc.
|
||||
-- All rights reserved.
|
||||
-- ****************************************************************
|
||||
|
||||
INFINERA-TP-NCTGIGE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
||||
DisplayString FROM SNMPv2-TC
|
||||
ifIndex FROM IF-MIB
|
||||
FloatTenths,InfnNctType,InfnChassisType FROM INFINERA-TC-MIB
|
||||
terminationPoint FROM INFINERA-REG-MIB;
|
||||
|
||||
|
||||
nctGigEMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200810200000Z"
|
||||
ORGANIZATION "Infinera"
|
||||
CONTACT-INFO
|
||||
"Infinera
|
||||
1322 Bordeaux Drive
|
||||
Sunnyvale, CA - 94089
|
||||
|
||||
Contact : Technical Support
|
||||
Email : support@infinera.com
|
||||
Phone : 1-877-INF-5288"
|
||||
DESCRIPTION
|
||||
" "
|
||||
REVISION "200810200000Z"
|
||||
DESCRIPTION
|
||||
"First Version"
|
||||
::= { terminationPoint 12 }
|
||||
|
||||
|
||||
|
||||
nctGigETable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NctGigEEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of NctGigE entries. Each entry is uniquely identified by the value of ifIndex."
|
||||
::= { nctGigEMIB 1 }
|
||||
|
||||
nctGigEEntry OBJECT-TYPE
|
||||
SYNTAX NctGigEEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A NctGigE entry containing information pertaining to Infinera NctGigE interfaces
|
||||
This table is a subclass of IfCommon. Entries will exist in this table only for
|
||||
interfaces of type ChannelCtp."
|
||||
INDEX { ifIndex }
|
||||
::= { nctGigETable 1 }
|
||||
|
||||
|
||||
NctGigEEntry ::= SEQUENCE {
|
||||
nctGigEPortType INTEGER,
|
||||
nctGigEForwardingState INTEGER,
|
||||
nctGigEPeerPortId INTEGER,
|
||||
nctGigEPeerChassisSerNum DisplayString,
|
||||
nctGigEPeerChassisId DisplayString,
|
||||
nctGigEPeerMcmSlotNum Integer32,
|
||||
nctGigEPeerChassisType InfnChassisType,
|
||||
interfaceTypeNCT InfnNctType
|
||||
}
|
||||
|
||||
nctGigEPortType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
nct(2),
|
||||
gige(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Identifies the NCT port."
|
||||
DEFVAL { none }
|
||||
::= { nctGigEEntry 1 }
|
||||
|
||||
|
||||
nctGigEForwardingState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(1),
|
||||
enabled(2),
|
||||
unknown(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Identifies the forwarding state of the port."
|
||||
DEFVAL { unknown }
|
||||
::= { nctGigEEntry 2 }
|
||||
|
||||
|
||||
nctGigEPeerPortId OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
nct1(2),
|
||||
nct2(3),
|
||||
gige(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Identifies the peer NCT port ID."
|
||||
DEFVAL { none }
|
||||
::= { nctGigEEntry 3 }
|
||||
|
||||
|
||||
nctGigEPeerChassisSerNum OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Serial number of the peer chassis to which the NCT cable is connected."
|
||||
::= { nctGigEEntry 4 }
|
||||
|
||||
|
||||
nctGigEPeerChassisId OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "PeerChassisId"
|
||||
::= { nctGigEEntry 5 }
|
||||
|
||||
|
||||
nctGigEPeerMcmSlotNum OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Slot number of the peer MCM."
|
||||
DEFVAL { 0 }
|
||||
::= { nctGigEEntry 6 }
|
||||
|
||||
|
||||
nctGigEPeerChassisType OBJECT-TYPE
|
||||
SYNTAX InfnChassisType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The peer chassis type."
|
||||
DEFVAL { cBand }
|
||||
::= { nctGigEEntry 7 }
|
||||
|
||||
interfaceTypeNCT OBJECT-TYPE
|
||||
SYNTAX InfnNctType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines the default active physical interface for NCT port"
|
||||
|
||||
::= { nctGigEEntry 8 }
|
||||
|
||||
-- Conformance Statements
|
||||
nctGigEConformance OBJECT IDENTIFIER ::= { nctGigEMIB 3 }
|
||||
nctGigECompliances OBJECT IDENTIFIER ::= { nctGigEConformance 1 }
|
||||
nctGigEGroups OBJECT IDENTIFIER ::= { nctGigEConformance 2 }
|
||||
|
||||
nctGigECompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the requirements for conformance to the NCTGIGE-MIB"
|
||||
MODULE
|
||||
MANDATORY-GROUPS { nctGigEGroup }
|
||||
::= { nctGigECompliances 1 }
|
||||
|
||||
nctGigEGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
nctGigEPortType,
|
||||
nctGigEForwardingState,
|
||||
nctGigEPeerPortId,
|
||||
nctGigEPeerChassisSerNum,
|
||||
nctGigEPeerChassisId,
|
||||
nctGigEPeerMcmSlotNum,
|
||||
nctGigEPeerChassisType,
|
||||
interfaceTypeNCT
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" A collection of objects for managing the nctGigE"
|
||||
::= { nctGigEGroups 1 }
|
||||
|
||||
|
||||
END
|