initial commit; version 22.5.12042
This commit is contained in:
161
mibs/infinera/INFINERA-TP-CLEARCHANNELCTP-MIB
Normal file
161
mibs/infinera/INFINERA-TP-CLEARCHANNELCTP-MIB
Normal file
@ -0,0 +1,161 @@
|
||||
-- *****************************************************************
|
||||
-- INFINERA-TP-CLEARCHANNELCTP-MIB
|
||||
--
|
||||
-- October 2008, Sharfuddin Syed / Narendra Gupta
|
||||
--
|
||||
--
|
||||
-- Copyright (c) 2008-2012 by Infinera Inc.
|
||||
-- All rights reserved.
|
||||
-- ****************************************************************
|
||||
|
||||
INFINERA-TP-CLEARCHANNELCTP-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
||||
DisplayString, TruthValue FROM SNMPv2-TC
|
||||
ifIndex FROM IF-MIB
|
||||
FloatTenths, InfnServiceType,
|
||||
InfnServiceMode,InfnSMQ FROM INFINERA-TC-MIB
|
||||
terminationPoint FROM INFINERA-REG-MIB;
|
||||
|
||||
clearChannelCtpMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200802180000Z"
|
||||
ORGANIZATION
|
||||
"Infinera"
|
||||
CONTACT-INFO
|
||||
"Infinera
|
||||
1322 Bordeaux Drive
|
||||
Sunnyvale, CA - 94089
|
||||
|
||||
Contact : Technical Support
|
||||
Email : support@infinera.com
|
||||
Phone : 1-877-INF-5288"
|
||||
DESCRIPTION
|
||||
" "
|
||||
|
||||
REVISION "200802180000Z"
|
||||
DESCRIPTION
|
||||
"First Version"
|
||||
::= { terminationPoint 9 }
|
||||
|
||||
|
||||
-- Conformance Statements
|
||||
|
||||
clearChannelCtpConformance OBJECT IDENTIFIER ::= { clearChannelCtpMIB 3 }
|
||||
clearChannelCtpCompliances OBJECT IDENTIFIER ::= { clearChannelCtpConformance 1 }
|
||||
clearChannelCtpGroups OBJECT IDENTIFIER ::= { clearChannelCtpConformance 2 }
|
||||
|
||||
-- February 18, 2008
|
||||
-- February 18, 2008
|
||||
|
||||
clearChannelCtpTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ClearChannelCtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of clearChannelCtp entries. Each entry is uniquely identified by the value of ifIndex."
|
||||
::= { clearChannelCtpMIB 1 }
|
||||
|
||||
clearChannelCtpEntry OBJECT-TYPE
|
||||
SYNTAX ClearChannelCtpEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A clearChannelCtp entry containing information pertaining to Infinera clearChannelCtp interfaces.
|
||||
This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of
|
||||
type clearChannelCtp."
|
||||
INDEX { ifIndex }
|
||||
::= { clearChannelCtpTable 1 }
|
||||
|
||||
ClearChannelCtpEntry ::= SEQUENCE {
|
||||
clearChannelCtpSupportingCircuitIdList DisplayString,
|
||||
clearChannelCtpLoopback INTEGER,
|
||||
clearChannelCtpPmHistStatsEnable INTEGER,
|
||||
clearChannelCtpConfiguredServiceType InfnServiceType,
|
||||
clearChannelCtpServiceMode InfnServiceMode,
|
||||
clearChannelCtpServiceModeQualifier InfnSMQ
|
||||
}
|
||||
|
||||
clearChannelCtpSupportingCircuitIdList OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An unordered list of the Circuit Id's which support this entry.
|
||||
This string contains the string representation of each supporting
|
||||
CircuitId, separated by a ',' (comma) if there is more than one."
|
||||
::= { clearChannelCtpEntry 1 }
|
||||
|
||||
clearChannelCtpLoopback OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none (1),
|
||||
terminal (2),
|
||||
facility (3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Flag that indicates if loopback is enabled or disabled."
|
||||
DEFVAL { none }
|
||||
::= { clearChannelCtpEntry 2 }
|
||||
|
||||
clearChannelCtpPmHistStatsEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled (1),
|
||||
disabled (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"Flag to enable or disable PM collection."
|
||||
DEFVAL { enabled }
|
||||
::= { clearChannelCtpEntry 3 }
|
||||
|
||||
clearChannelCtpConfiguredServiceType OBJECT-TYPE
|
||||
SYNTAX InfnServiceType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The configured service type."
|
||||
::= { clearChannelCtpEntry 4 }
|
||||
|
||||
clearChannelCtpServiceMode OBJECT-TYPE
|
||||
SYNTAX InfnServiceMode
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "ServiceMode of ClearChannel client CTP."
|
||||
DEFVAL { none }
|
||||
::= { clearChannelCtpEntry 5 }
|
||||
|
||||
clearChannelCtpServiceModeQualifier OBJECT-TYPE
|
||||
SYNTAX InfnSMQ
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The Service Mode Qualifier (SMQ) of the ClearChannel client CTP (i.e., the mode/type of service in which
|
||||
this ClearChannel client CTP is being used,). None<6E> is the default value indicated for the ClearChannel client CTP when it is initially created."
|
||||
DEFVAL { none }
|
||||
::= { clearChannelCtpEntry 6 }
|
||||
|
||||
clearChannelCtpCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the requirements for conformance to the CLEARCHANNELCTP-MIB"
|
||||
MODULE
|
||||
MANDATORY-GROUPS { clearChannelCtpGroup }
|
||||
::= { clearChannelCtpCompliances 1 }
|
||||
|
||||
clearChannelCtpGroup OBJECT-GROUP
|
||||
OBJECTS { clearChannelCtpSupportingCircuitIdList,
|
||||
clearChannelCtpLoopback,
|
||||
clearChannelCtpPmHistStatsEnable,
|
||||
clearChannelCtpConfiguredServiceType,
|
||||
clearChannelCtpServiceMode,
|
||||
clearChannelCtpServiceModeQualifier }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" A collection of objects for managing the clearChannelCtp"
|
||||
::= { clearChannelCtpGroups 1 }
|
||||
END
|
||||
|
Reference in New Issue
Block a user