initial commit; version 22.5.12042
This commit is contained in:
146
mibs/huawei/HUAWEI-ELECTRO-SWITCH-MIB
Normal file
146
mibs/huawei/HUAWEI-ELECTRO-SWITCH-MIB
Normal file
@ -0,0 +1,146 @@
|
||||
-- ============================================================================
|
||||
-- Copyright (C) 2014 by HUAWEI TECHNOLOGIES. All rights reserved.
|
||||
-- Description: The mib is used for defining the MIB objects of electronic switch.
|
||||
-- Reference:
|
||||
-- Version: V1.08
|
||||
-- ============================================================================
|
||||
|
||||
HUAWEI-ELECTRO-SWITCH-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
huaweiMgmt
|
||||
FROM HUAWEI-MIB
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, Integer32
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
hwEthernetPort MODULE-IDENTITY
|
||||
LAST-UPDATED "201406300000Z"
|
||||
ORGANIZATION "Huawei Technologies Co.,Ltd."
|
||||
CONTACT-INFO
|
||||
"Huawei Industrial Base
|
||||
Bantian, Longgang
|
||||
Shenzhen 518129
|
||||
People's Republic of China
|
||||
Website: http://www.huawei.com
|
||||
Email: support@huawei.com
|
||||
"
|
||||
DESCRIPTION
|
||||
"
|
||||
The mib is used for defining the MIB objects of electronic switch.
|
||||
"
|
||||
|
||||
-- Revision history
|
||||
REVISION "201406300000Z"
|
||||
DESCRIPTION "V1.08, 1. modified module name 'hwEthernet' to 'hwEthernetPort'.
|
||||
2. removed all hyphens (-) from enumerated values of hwElectroSwitchLocation."
|
||||
|
||||
REVISION "201011100000Z"
|
||||
DESCRIPTION "V1.07,Modified the description of hwElectroSwitchEntry."
|
||||
|
||||
REVISION "201008250000Z"
|
||||
DESCRIPTION "V1.06, modified the contact-info and the revision history. Modified the description of leaves."
|
||||
|
||||
REVISION "201006170000Z"
|
||||
DESCRIPTION "V1.05, added the description of the MIB header file; added the revision history;
|
||||
modified the object description in hwElectroSwitchTable."
|
||||
|
||||
REVISION "200701300000Z"
|
||||
DESCRIPTION "V1.00, completed the draft."
|
||||
::= { huaweiMgmt 14 }
|
||||
--
|
||||
-- hwElectroSwitch
|
||||
--
|
||||
hwElectroSwitchTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HwElectroSwitchEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
Electronic switch table.
|
||||
This table is used for querying and setting the electronic function. By setting
|
||||
the electronic function, the user can select the port on the control board or
|
||||
the upstream interface board for upstream transmission.
|
||||
The index of this table is hwElectroSwitchIndex.
|
||||
"
|
||||
::= { hwEthernetPort 15 }
|
||||
|
||||
hwElectroSwitchEntry OBJECT-TYPE
|
||||
SYNTAX HwElectroSwitchEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
Electronic switch table.
|
||||
This table is used for querying and setting the electronic function. By setting
|
||||
the electronic function, the user can select the port on the control board or
|
||||
the upstream interface board for upstream transmission.
|
||||
The index of this entry is hwElectroSwitchIndex.
|
||||
"
|
||||
INDEX { hwElectroSwitchIndex }
|
||||
::= { hwElectroSwitchTable 1 }
|
||||
|
||||
HwElectroSwitchEntry ::=
|
||||
SEQUENCE{
|
||||
hwElectroSwitchIndex
|
||||
Integer32,
|
||||
hwElectroSwitchLocation
|
||||
INTEGER,
|
||||
hwElectroSwitchLocation0Info
|
||||
OCTET STRING,
|
||||
hwElectroSwitchLocation1Info
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
hwElectroSwitchIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..8)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
Index of this table.
|
||||
"
|
||||
::= { hwElectroSwitchEntry 1 }
|
||||
|
||||
hwElectroSwitchLocation OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
location0(1),
|
||||
location1(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
The switch location of electronic switch.
|
||||
Options:
|
||||
1. location0(1) -The electronic switch points to the ports of mainboard.
|
||||
2. location1(2) -The electronic switch points to the ports of upstream interface board.
|
||||
"
|
||||
::= { hwElectroSwitchEntry 2 }
|
||||
|
||||
hwElectroSwitchLocation0Info OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..96))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
The available port description when electronic switch location is
|
||||
location-0, including frame index, slot index and port index.
|
||||
If the operation granularity is board-class, no port index is
|
||||
given. If the port is VOIP port, the description is VOIP.
|
||||
"
|
||||
::= { hwElectroSwitchEntry 3 }
|
||||
|
||||
hwElectroSwitchLocation1Info OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..96))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
The available port description when electronic switch location is
|
||||
location-1, including frame index, slot index and port index.
|
||||
If the operation granularity is board-class, no port index is given.
|
||||
"
|
||||
::= { hwElectroSwitchEntry 4 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user