initial commit; version 22.5.12042
This commit is contained in:
540
mibs/hp/HPN-ICF-TE-TUNNEL-MIB
Normal file
540
mibs/hp/HPN-ICF-TE-TUNNEL-MIB
Normal file
@ -0,0 +1,540 @@
|
||||
-- =================================================================
|
||||
-- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P.
|
||||
--
|
||||
-- Description: This MIB define objects for MPLS Te Tunnel.
|
||||
-- Reference:
|
||||
-- Version: V1.0
|
||||
-- History:
|
||||
-- V1.0 2011-03-24 Created by fengnina 04924.
|
||||
-- ==================================================================
|
||||
|
||||
HPN-ICF-TE-TUNNEL-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
hpnicfCommon
|
||||
FROM HPN-ICF-OID-MIB
|
||||
MplsTunnelIndex, MplsTunnelInstanceIndex, MplsExtendedTunnelId, MplsLabel
|
||||
FROM MPLS-TC-STD-MIB
|
||||
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
RowPointer
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
hpnicfTeTunnel MODULE-IDENTITY
|
||||
LAST-UPDATED "201103240948Z" -- March 24, 2011 at 09:48 GMT
|
||||
ORGANIZATION
|
||||
""
|
||||
CONTACT-INFO
|
||||
""
|
||||
DESCRIPTION
|
||||
"This MIB contains managed object definitions for the
|
||||
Multiprotocol Label Switching (MPLS) Te Tunnel."
|
||||
::= { hpnicfCommon 115 }
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
hpnicfTeTunnelScalars OBJECT IDENTIFIER ::= { hpnicfTeTunnel 1 }
|
||||
|
||||
hpnicfTeTunnelMaxTunnelIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The max value of tunnel id is permitted configure on the device."
|
||||
::= { hpnicfTeTunnelScalars 1 }
|
||||
|
||||
hpnicfTeTunnelObjects OBJECT IDENTIFIER ::= { hpnicfTeTunnel 2 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HpnicfTeTunnelStaticCrlspEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information for static-crlsp, and through this
|
||||
to get detail information about this static-crlsp. Only support
|
||||
transit LSR and egress LSR."
|
||||
::= { hpnicfTeTunnelObjects 1 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspEntry OBJECT-TYPE
|
||||
SYNTAX HpnicfTeTunnelStaticCrlspEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes static-crlsp information."
|
||||
INDEX { hpnicfTeTunnelStaticCrlspInLabel }
|
||||
::= { hpnicfTeTunnelStaticCrlspTable 1 }
|
||||
|
||||
HpnicfTeTunnelStaticCrlspEntry ::=
|
||||
SEQUENCE {
|
||||
hpnicfTeTunnelStaticCrlspInLabel
|
||||
MplsLabel,
|
||||
hpnicfTeTunnelStaticCrlspName
|
||||
OCTET STRING,
|
||||
hpnicfTeTunnelStaticCrlspStatus
|
||||
INTEGER,
|
||||
hpnicfTeTunnelStaticCrlspRole
|
||||
INTEGER,
|
||||
hpnicfTeTunnelStaticCrlspXCPointer
|
||||
RowPointer
|
||||
}
|
||||
|
||||
hpnicfTeTunnelStaticCrlspInLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is unique label value that manualy assigned. Uniquely
|
||||
identifies a static-crlsp. Managers should use this to obtain
|
||||
detail static-crlsp information."
|
||||
::= { hpnicfTeTunnelStaticCrlspEntry 1 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..15))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unique name assigned to the static-crlsp."
|
||||
::= { hpnicfTeTunnelStaticCrlspEntry 2 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
up(1),
|
||||
down(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the actual status of this static-crlsp,
|
||||
The value must be up when the static-crlsp status is up and
|
||||
the value must be down when the static-crlsp status is down."
|
||||
::= { hpnicfTeTunnelStaticCrlspEntry 3 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspRole OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
transit(1),
|
||||
tail(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicate the role of this static-crlsp. This value must
|
||||
be transit at transit point of the tunnel, and tail at
|
||||
terminating point of the tunnel."
|
||||
::= { hpnicfTeTunnelStaticCrlspEntry 4 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspXCPointer OBJECT-TYPE
|
||||
SYNTAX RowPointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This pointer unique identify a row of mplsXCTable.
|
||||
This value should be zeroDotZero when the static-crlsp
|
||||
is down. The mplsXCTable identifies the segments that
|
||||
compose this tunnel, their characteristics, and relationships
|
||||
to each other."
|
||||
::= { hpnicfTeTunnelStaticCrlspEntry 5 }
|
||||
|
||||
hpnicfTeTunnelCoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HpnicfTeTunnelCoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information for Co-routed reverse crlsp and
|
||||
infomation of Co-routed bidirectional Tunnel Interface.
|
||||
If hpnicfCorouteTunnelLspInstance is zero, to obtain infomation of
|
||||
Co-routed bidirectional Tunnel Interface, otherwise to obtain
|
||||
Co-routed reverse crlsp infomation."
|
||||
::= { hpnicfTeTunnelObjects 2 }
|
||||
|
||||
hpnicfTeTunnelCoEntry OBJECT-TYPE
|
||||
SYNTAX HpnicfTeTunnelCoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes Co-routed infomation of
|
||||
bidirectional Tunnel Interface and reserver lsp information."
|
||||
INDEX { hpnicfTeTunnelCoIndex, hpnicfTeTunnelCoLspInstance, hpnicfTeTunnelCoIngressLSRId, hpnicfTeTunnelCoEgressLSRId }
|
||||
::= { hpnicfTeTunnelCoTable 1 }
|
||||
|
||||
HpnicfTeTunnelCoEntry ::=
|
||||
SEQUENCE {
|
||||
hpnicfTeTunnelCoIndex
|
||||
MplsTunnelIndex,
|
||||
hpnicfTeTunnelCoLspInstance
|
||||
MplsTunnelInstanceIndex,
|
||||
hpnicfTeTunnelCoIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelCoEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelCoBiMode
|
||||
INTEGER,
|
||||
hpnicfTeTunnelCoReverseLspInstance
|
||||
MplsTunnelInstanceIndex,
|
||||
hpnicfTeTunnelCoReverseLspXCPointer
|
||||
RowPointer
|
||||
}
|
||||
|
||||
hpnicfTeTunnelCoIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a set of tunnel instances between a pair
|
||||
of ingress and egress LSRs that specified at originating point.
|
||||
This value should be equal to the value signaled in the
|
||||
Tunnel Id of the Session object."
|
||||
::= { hpnicfTeTunnelCoEntry 1 }
|
||||
|
||||
hpnicfTeTunnelCoLspInstance OBJECT-TYPE
|
||||
SYNTAX MplsTunnelInstanceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When obtain infomation of Co-routed bidirectional Tunnel Interface,
|
||||
this vlaue should be zero. And this value must be LspID to obtain
|
||||
reverse crlsp information. Values greater than 0, but less than or
|
||||
equal to 65535, should be useless."
|
||||
::= { hpnicfTeTunnelCoEntry 2 }
|
||||
|
||||
hpnicfTeTunnelCoIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with this tunnel instance.
|
||||
This vlaue is equal to the LsrID of originating endpoint."
|
||||
::= { hpnicfTeTunnelCoEntry 3 }
|
||||
|
||||
hpnicfTeTunnelCoEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with this tunnel instance.
|
||||
This vlaue is equal to the LsrID of terminating point."
|
||||
::= { hpnicfTeTunnelCoEntry 4 }
|
||||
|
||||
hpnicfTeTunnelCoBiMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
coroutedActive(1),
|
||||
coroutedPassive(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This vlaue indicated the bidirection mode of tunnel interface.
|
||||
The valuemust be coroutedActive at the originating point of the
|
||||
tunnel and coroutedPassive at the terminating point."
|
||||
::= { hpnicfTeTunnelCoEntry 5 }
|
||||
|
||||
hpnicfTeTunnelCoReverseLspInstance OBJECT-TYPE
|
||||
SYNTAX MplsTunnelInstanceIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated the reverse lsp instance, and
|
||||
should be equal to obverse lsp instance."
|
||||
::= { hpnicfTeTunnelCoEntry 6 }
|
||||
|
||||
hpnicfTeTunnelCoReverseLspXCPointer OBJECT-TYPE
|
||||
SYNTAX RowPointer
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This pointer unique index to mplsXCTable of the reverse lsp.
|
||||
The mplsXCTable identifies the segments that compose this tunnel,
|
||||
their characteristics, and relationships to each other. A
|
||||
value of zeroDotZero indicate that there is no crlsp assigned
|
||||
to this."
|
||||
::= { hpnicfTeTunnelCoEntry 7 }
|
||||
|
||||
hpnicfTeTunnelPsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HpnicfTeTunnelPsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table defines some objects for managers to obtain
|
||||
TE tunnel Protection Switching group current status information."
|
||||
::= { hpnicfTeTunnelObjects 3 }
|
||||
|
||||
hpnicfTeTunnelPsEntry OBJECT-TYPE
|
||||
SYNTAX HpnicfTeTunnelPsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entry in this table describes TE tunnel Protection
|
||||
Switching group infromation."
|
||||
INDEX { hpnicfTeTunnelPsIndex, hpnicfTeTunnelPsIngressLSRId, hpnicfTeTunnelPsEgressLSRId }
|
||||
::= { hpnicfTeTunnelPsTable 1 }
|
||||
|
||||
HpnicfTeTunnelPsEntry ::=
|
||||
SEQUENCE {
|
||||
hpnicfTeTunnelPsIndex
|
||||
MplsTunnelIndex,
|
||||
hpnicfTeTunnelPsIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelPsEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelPsProtectIndex
|
||||
MplsTunnelIndex,
|
||||
hpnicfTeTunnelPsProtectIngressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelPsProtectEgressLSRId
|
||||
MplsExtendedTunnelId,
|
||||
hpnicfTeTunnelPsProtectType
|
||||
INTEGER,
|
||||
hpnicfTeTunnelPsRevertiveMode
|
||||
INTEGER,
|
||||
hpnicfTeTunnelPsWtrTime
|
||||
Unsigned32,
|
||||
hpnicfTeTunnelPsHoldOffTime
|
||||
Unsigned32,
|
||||
hpnicfTeTunnelPsSwitchMode
|
||||
INTEGER,
|
||||
hpnicfTeTunnelPsWorkPathStatus
|
||||
INTEGER,
|
||||
hpnicfTeTunnelPsProtectPathStatus
|
||||
INTEGER,
|
||||
hpnicfTeTunnelPsSwitchResult
|
||||
INTEGER
|
||||
}
|
||||
|
||||
hpnicfTeTunnelPsIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a TE tunnel Protection Switching group
|
||||
instance. This value must be equal to the tunnel id of work
|
||||
tunnel instance."
|
||||
::= { hpnicfTeTunnelPsEntry 1 }
|
||||
|
||||
hpnicfTeTunnelPsIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with work tunnel instance."
|
||||
::= { hpnicfTeTunnelPsEntry 2 }
|
||||
|
||||
hpnicfTeTunnelPsEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with work tunnel instance."
|
||||
::= { hpnicfTeTunnelPsEntry 3 }
|
||||
|
||||
hpnicfTeTunnelPsProtectIndex OBJECT-TYPE
|
||||
SYNTAX MplsTunnelIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a TE tunnel Protection Switching
|
||||
group instance. This value must be equal to the tunnel
|
||||
id of TE tunnel Protection Switching group instance."
|
||||
::= { hpnicfTeTunnelPsEntry 4 }
|
||||
|
||||
hpnicfTeTunnelPsProtectIngressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity the ingress LSR associated with TE tunnel
|
||||
Protection Switching group instance."
|
||||
::= { hpnicfTeTunnelPsEntry 5 }
|
||||
|
||||
hpnicfTeTunnelPsProtectEgressLSRId OBJECT-TYPE
|
||||
SYNTAX MplsExtendedTunnelId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identity of the egress LSR associated with TE tunnel
|
||||
Protection Switching group instance."
|
||||
::= { hpnicfTeTunnelPsEntry 6 }
|
||||
|
||||
hpnicfTeTunnelPsProtectType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
oneToOne(1),
|
||||
onePlusOne(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated TE tunnel Protection Switching group
|
||||
type. The default value is oneToOne."
|
||||
DEFVAL { oneToOne }
|
||||
::= { hpnicfTeTunnelPsEntry 7 }
|
||||
|
||||
hpnicfTeTunnelPsRevertiveMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
revertive(1),
|
||||
noRevertive(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated protect switch mode. The value must be
|
||||
revertive or nonRevertive, default value is revertive.
|
||||
"
|
||||
DEFVAL { revertive }
|
||||
::= { hpnicfTeTunnelPsEntry 8 }
|
||||
|
||||
hpnicfTeTunnelPsWtrTime OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..60)
|
||||
UNITS "30 seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The cycle time that switch to protect tunnel."
|
||||
DEFVAL { 24 }
|
||||
::= { hpnicfTeTunnelPsEntry 9 }
|
||||
|
||||
hpnicfTeTunnelPsHoldOffTime OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..20)
|
||||
UNITS "500ms"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value is switchback delay time. When detected the work path
|
||||
fault, switch to protect path after this time."
|
||||
DEFVAL { 0 }
|
||||
::= { hpnicfTeTunnelPsEntry 10 }
|
||||
|
||||
hpnicfTeTunnelPsSwitchMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
uniDirectional(1),
|
||||
biDirectional(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated TE tunnel Protection Switching
|
||||
group switch mode."
|
||||
DEFVAL { uniDirectional }
|
||||
::= { hpnicfTeTunnelPsEntry 11 }
|
||||
|
||||
hpnicfTeTunnelPsWorkPathStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(1),
|
||||
noDefect(2),
|
||||
inDefect(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates work path status. none, noDefect, inDefect
|
||||
will be used."
|
||||
::= { hpnicfTeTunnelPsEntry 12 }
|
||||
|
||||
hpnicfTeTunnelPsProtectPathStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(1),
|
||||
noDefect(2),
|
||||
inDefect(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates protect path status. none, noDefect,
|
||||
inDefect(3) will be used."
|
||||
::= { hpnicfTeTunnelPsEntry 13 }
|
||||
|
||||
hpnicfTeTunnelPsSwitchResult OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
workPath(1),
|
||||
protectPath(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicated current using path is work path or protect
|
||||
path."
|
||||
::= { hpnicfTeTunnelPsEntry 14 }
|
||||
|
||||
hpnicfTeTunnelNotifications OBJECT IDENTIFIER ::= { hpnicfTeTunnel 3 }
|
||||
|
||||
hpnicfTeTunnelNotificationsPrefix OBJECT IDENTIFIER ::= { hpnicfTeTunnelNotifications 0 }
|
||||
|
||||
hpnicfTeTunnelPsSwitchWtoP NOTIFICATION-TYPE
|
||||
OBJECTS { hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is generated when protect workgroup switch from
|
||||
work tunnel to protect tunnel."
|
||||
::= { hpnicfTeTunnelNotificationsPrefix 1 }
|
||||
|
||||
hpnicfTeTunnelPsSwitchPtoW NOTIFICATION-TYPE
|
||||
OBJECTS { hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is generated when protect workgroup switch from
|
||||
protect tunnel to work tunnel."
|
||||
::= { hpnicfTeTunnelNotificationsPrefix 2 }
|
||||
|
||||
hpnicfTeTunnelConformance OBJECT IDENTIFIER ::= { hpnicfTeTunnel 4 }
|
||||
|
||||
hpnicfTeTunnelCompliances OBJECT IDENTIFIER ::= { hpnicfTeTunnelConformance 1 }
|
||||
|
||||
hpnicfTeTunnelCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { hpnicfTeTunnelNotificationsGroup, hpnicfTeTunnelScalarsGroup, hpnicfTeTunnelStaticCrlspGroup, hpnicfTeTunnelCorouteGroup, hpnicfTeTunnelPsGroup
|
||||
}
|
||||
::= { hpnicfTeTunnelCompliances 1 }
|
||||
|
||||
hpnicfTeTunnelGroups OBJECT IDENTIFIER ::= { hpnicfTeTunnelConformance 2 }
|
||||
|
||||
hpnicfTeTunnelNotificationsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { hpnicfTeTunnelPsSwitchPtoW, hpnicfTeTunnelPsSwitchWtoP }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This group contains MPLS Te Tunnel traps."
|
||||
::= { hpnicfTeTunnelGroups 1 }
|
||||
|
||||
hpnicfTeTunnelScalarsGroup OBJECT-GROUP
|
||||
OBJECTS { hpnicfTeTunnelMaxTunnelIndex }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Scalar object needed to implement MPLS te tunnels."
|
||||
::= { hpnicfTeTunnelGroups 2 }
|
||||
|
||||
hpnicfTeTunnelStaticCrlspGroup OBJECT-GROUP
|
||||
OBJECTS { hpnicfTeTunnelStaticCrlspName, hpnicfTeTunnelStaticCrlspStatus, hpnicfTeTunnelStaticCrlspRole, hpnicfTeTunnelStaticCrlspXCPointer }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering static-crlsp information."
|
||||
::= { hpnicfTeTunnelGroups 3 }
|
||||
|
||||
hpnicfTeTunnelCorouteGroup OBJECT-GROUP
|
||||
OBJECTS { hpnicfTeTunnelCoBiMode, hpnicfTeTunnelCoReverseLspInstance, hpnicfTeTunnelCoReverseLspXCPointer }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering Co-routed reverse crlsp information."
|
||||
::= { hpnicfTeTunnelGroups 4 }
|
||||
|
||||
hpnicfTeTunnelPsGroup OBJECT-GROUP
|
||||
OBJECTS { hpnicfTeTunnelPsProtectIndex, hpnicfTeTunnelPsProtectIngressLSRId, hpnicfTeTunnelPsProtectEgressLSRId, hpnicfTeTunnelPsProtectType, hpnicfTeTunnelPsRevertiveMode,
|
||||
hpnicfTeTunnelPsWtrTime, hpnicfTeTunnelPsHoldOffTime, hpnicfTeTunnelPsSwitchMode, hpnicfTeTunnelPsWorkPathStatus, hpnicfTeTunnelPsProtectPathStatus,
|
||||
hpnicfTeTunnelPsSwitchResult }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Objects for quering protect workgroup information."
|
||||
::= { hpnicfTeTunnelGroups 5 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user