initial commit; version 22.5.12042
This commit is contained in:
244
mibs/hp/CPQN54NN-MIB
Normal file
244
mibs/hp/CPQN54NN-MIB
Normal file
@ -0,0 +1,244 @@
|
||||
-- * Revision 1.2 1997/12/20 03:06:32 asmith
|
||||
|
||||
CPQN54NN-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
enterprises FROM RFC1155-SMI
|
||||
sysUpTime, sysDescr FROM RFC1213-MIB
|
||||
TRAP-TYPE FROM RFC-1215
|
||||
OBJECT-TYPE FROM RFC-1212;
|
||||
|
||||
|
||||
-- Organization & Product branches
|
||||
|
||||
|
||||
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
||||
|
||||
--
|
||||
-- Compaq Products
|
||||
--
|
||||
cpqGigaSwitch OBJECT IDENTIFIER ::= { compaq 111}
|
||||
cpqGigaSwitchProd OBJECT IDENTIFIER ::= { cpqGigaSwitch 1}
|
||||
cpqGigaSwitchId5422 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 1}
|
||||
cpqGigaSwitchId5411 OBJECT IDENTIFIER ::= { cpqGigaSwitchProd 2}
|
||||
|
||||
|
||||
--
|
||||
-- MIB Objects
|
||||
--
|
||||
cpqGigaSwitchMib OBJECT IDENTIFIER ::= { cpqGigaSwitch 3 }
|
||||
|
||||
--
|
||||
-- System group
|
||||
--
|
||||
cpqGigaSwitchSystem OBJECT IDENTIFIER ::= { cpqGigaSwitchMib 1 }
|
||||
|
||||
-- Configuration save objects. These objects are used by the network
|
||||
-- management application to save configuration changes into the
|
||||
-- persistant store. There are 2 stores on the device; a primary and
|
||||
-- a secondary.
|
||||
|
||||
cpqSaveConfiguration OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
saveToPrimary(1),
|
||||
saveToSecondary(2)
|
||||
}
|
||||
ACCESS write-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"When this object is set, the device will copy the contents
|
||||
of the configuration database to a buffer and save it to the
|
||||
persistant store specified by the value of the object. The
|
||||
save is performed asynchronously, and the snmp agent will continue
|
||||
to respond to both gets and sets while the save is taking
|
||||
place. A network management application may use the
|
||||
cpqSaveStatus object to determine when the asynchronous
|
||||
save operation has completed."
|
||||
::= { cpqGigaSwitchSystem 3 }
|
||||
|
||||
cpqSaveStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
saveInProgress(1),
|
||||
saveNotInProgress(2)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object will return the status of a save operation invoked
|
||||
by setting the cpqSaveConfiguration object. A network
|
||||
management application can read this object to determine that a
|
||||
save operation has completed."
|
||||
::= { cpqGigaSwitchSystem 4 }
|
||||
|
||||
cpqCurrentConfigInUse OBJECT-TYPE
|
||||
SYNTAX INTEGER { primary(1), secondary(2) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Shows which configuration store was used at last boot"
|
||||
::= { cpqGigaSwitchSystem 5 }
|
||||
|
||||
cpqConfigToUseOnReboot OBJECT-TYPE
|
||||
SYNTAX INTEGER { primary(1), secondary(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Controls which configuration store will be used on next reboot."
|
||||
::= { cpqGigaSwitchSystem 6 }
|
||||
|
||||
--
|
||||
-- Assorted OIDs that are pointed to by other MIBs
|
||||
--
|
||||
cpqOids OBJECT IDENTIFIER ::= { cpqGigaSwitch 2 }
|
||||
|
||||
--
|
||||
-- OIDs for as-yet-unstandardised 802.3 MAU types
|
||||
-- (see MAU MIB for usage)
|
||||
--
|
||||
cpqMauType OBJECT IDENTIFIER ::= { cpqOids 1 }
|
||||
|
||||
cpqMauType1000BaseSX OBJECT IDENTIFIER ::= { cpqMauType 1 }
|
||||
-- "X fiber over short-wavelength laser PMD as specified
|
||||
-- in clause 38, duplex mode unknown"
|
||||
|
||||
cpqMauType1000BaseLX OBJECT IDENTIFIER ::= { cpqMauType 2 }
|
||||
-- "X fiber over long-wavelength laser PMD as specified
|
||||
-- in clause 38, duplex mode unknown"
|
||||
|
||||
cpqMauType1000BaseCX OBJECT IDENTIFIER ::= { cpqMauType 3 }
|
||||
-- "X copper over 150-ohm balanced cable PMD as specified
|
||||
-- in clause 39, duplex mode unknown"
|
||||
|
||||
cpqMauType1000BaseSXFD OBJECT IDENTIFIER ::= { cpqMauType 4 }
|
||||
-- "X fiber over short-wavelength laser PMD as specified
|
||||
-- in clause 38, full-duplex mode"
|
||||
|
||||
cpqMauType1000BaseLXFD OBJECT IDENTIFIER ::= { cpqMauType 5 }
|
||||
-- "X fiber over long-wavelength laser PMD as specified
|
||||
-- in clause 38, full-duplex mode"
|
||||
|
||||
cpqMauType1000BaseCXFD OBJECT IDENTIFIER ::= { cpqMauType 6 }
|
||||
-- "X copper over 150-ohm balanced cable PMD as specified
|
||||
-- in clause 39, full-duplex mode"
|
||||
|
||||
|
||||
--
|
||||
-- Traps
|
||||
--
|
||||
overheat TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"A overheat trap indicates that the on board
|
||||
tempature sensor has reported a overheat
|
||||
condition. System will shutdown until unit has
|
||||
sufficiently cooled such that operation may begin
|
||||
again. A cold start trap will be issued when
|
||||
the unit has come back on line."
|
||||
|
||||
--#TYPE "overheat"
|
||||
--#SUMMARY "overheat"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY CRITICAL
|
||||
--#TIMEINDEX 99
|
||||
|
||||
::= 6
|
||||
|
||||
fanfailed TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"A fan failed trap indicates one or more of the
|
||||
cooling fans inside the device has failed. A
|
||||
fanOK trap will be sent once the fan has attained
|
||||
normal operation."
|
||||
--#TYPE "fanfailed"
|
||||
--#SUMMARY "fanfailed"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY MAJOR
|
||||
--#TIMEINDEX 99
|
||||
|
||||
::= 7
|
||||
|
||||
fanOK TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"A fan has transitioned out of a failure state and
|
||||
is now operating correctly."
|
||||
--#TYPE "fanOk"
|
||||
--#SUMMARY "fanOk"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY INFORMATIONAL
|
||||
--#TIMEINDEX 99
|
||||
|
||||
::= 8
|
||||
|
||||
invalidLoginAttempt TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"A user attempted to login to console or by telnet but was refused
|
||||
access due to incorrect username or password"
|
||||
--#TYPE "invalidLoginAttempt"
|
||||
--#SUMMARY "invalidLoginAttempt"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY INFORMATIONAL
|
||||
--#TIMEINDEX 99
|
||||
|
||||
::= 9
|
||||
|
||||
powerSupplyFail TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"One or more sources of power to this agent has failed.
|
||||
Presumably a redundant power-supply has taken over."
|
||||
--#TYPE "powerSupplyFail"
|
||||
--#SUMMARY "powerSupplyFail"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY MAJOR
|
||||
--#TIMEINDEX 99
|
||||
::= 10
|
||||
|
||||
powerSupplyGood TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"One or more previously bad sources of power to this agent
|
||||
has come back to life without causing an agent restart."
|
||||
--#TYPE "powerSupplyGood"
|
||||
--#SUMMARY "powerSupplyGood"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY INFORMATIONAL
|
||||
--#TIMEINDEX 99
|
||||
::= 11
|
||||
|
||||
rpsAlarm TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"Attached Redundant Power Supply device is indicating
|
||||
an alarm condition."
|
||||
--#TYPE "rpsAlrm"
|
||||
--#SUMMARY "rpsAlarm"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY MAJOR
|
||||
--#TIMEINDEX 99
|
||||
::= 12
|
||||
|
||||
rpsNoAlarm TRAP-TYPE
|
||||
ENTERPRISE cpqGigaSwitch
|
||||
VARIABLES { sysUpTime, sysDescr }
|
||||
DESCRIPTION
|
||||
"Attached Redundant Power Supply device is no longer
|
||||
indicating an alarm condition."
|
||||
--#TYPE "rpsNoAlarm"
|
||||
--#SUMMARY "rpsNoAlarm"
|
||||
--#ARGUMENTS {2}
|
||||
--#SEVERITY INFORMATIONAL
|
||||
--#TIMEINDEX 99
|
||||
::= 13
|
||||
|
||||
|
||||
END
|