@ -0,0 +1,323 @@
|
||||
-- *******************************************************************
|
||||
-- FS-DOT11-MESH-HWMP-MIB : FS MIB
|
||||
-- May 2010, liyan
|
||||
--
|
||||
-- Copyright (c) 2010 by FS.COM Inc..
|
||||
-- All rights reserved.
|
||||
-- *******************************************************************
|
||||
FS-DOT11-MESH-HWMP-MIB DEFINITIONS ::= BEGIN
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE
|
||||
--INTEGER
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
NOTIFICATION-GROUP,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
ifIndex
|
||||
FROM RFC1213-MIB
|
||||
fsMgmt
|
||||
FROM FS-SMI;
|
||||
--*******************************************
|
||||
--* module definition
|
||||
--*******************************************
|
||||
fsDot11MeshHWMPMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201002260000Z"
|
||||
ORGANIZATION
|
||||
"FS.COM Inc.."
|
||||
CONTACT-INFO
|
||||
"Tel: 400-865-2852
|
||||
E-mail: https://www.fs.com/live_chat_service_mail.html "
|
||||
|
||||
DESCRIPTION
|
||||
"
|
||||
Wlan software private MIB for FS SNC according to the China
|
||||
Mobile standard. This is device manage MIB.
|
||||
"
|
||||
REVISION "201002280000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
|
||||
::= { fsMgmt 92 }
|
||||
|
||||
-- **********************************************************************
|
||||
-- * dot11MeshHWMPConfig TABLE start *
|
||||
-- **********************************************************************
|
||||
apdot11MeshHWMPConfigObjects OBJECT IDENTIFIER ::= { fsDot11MeshHWMPMIB 1 }
|
||||
|
||||
dot11MeshHWMPConfigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Dot11MeshHWMPConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Mesh Station HWMP Configuration attributes. In tabular form to
|
||||
allow for multiple instances on an agent."
|
||||
::={ apdot11MeshHWMPConfigObjects 1 }
|
||||
|
||||
dot11MeshHWMPConfigEntry OBJECT-TYPE
|
||||
SYNTAX Dot11MeshHWMPConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the dot11MeshHWMPConfigTable. It is possible for there
|
||||
to be multiple IEEE 802.11 interfaces on one agent, each with its
|
||||
unique MAC address. The relationship between an IEEE 802.11
|
||||
interface and an interface in the context of the Internet-standard
|
||||
MIB is one-to-one. As such, the value of an ifIndex object instance
|
||||
can be directly used to identify corresponding instances of the
|
||||
objects defined herein.
|
||||
ifIndex - Each IEEE 802.11 interface is represented by an ifEntry.
|
||||
Interface tables in this MIB module are indexed by ifIndex."
|
||||
INDEX { ifIndex }
|
||||
::= { dot11MeshHWMPConfigTable 1 }
|
||||
|
||||
Dot11MeshHWMPConfigEntry ::=
|
||||
SEQUENCE {
|
||||
dot11MeshHWMPmaxPREQretries INTEGER,
|
||||
dot11MeshHWMPnetDiameter INTEGER,
|
||||
dot11MeshHWMPnetDiameterTraversalTime INTEGER,
|
||||
dot11MeshHWMPpreqMinInterval INTEGER,
|
||||
dot11MeshHWMPperrMinInterval INTEGER,
|
||||
dot11MeshHWMPactivePathToRootTimeout INTEGER,
|
||||
dot11MeshHWMPactivePathTimeout INTEGER,
|
||||
dot11MeshHWMProotMode INTEGER,
|
||||
dot11MeshHWMProotInterval INTEGER,
|
||||
dot11MeshHWMPrannInterval INTEGER,
|
||||
dot11MeshHWMPtargetOnly INTEGER,
|
||||
dot11MeshHWMPmaintenanceInterval INTEGER,
|
||||
dot11MeshHWMPconfirmationInterval INTEGER
|
||||
}
|
||||
|
||||
dot11MeshHWMPmaxPREQretries OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..255)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
|
||||
This attribute shall specify the number of Action frames containing
|
||||
a PREQ that an originator mesh STA can send to a particular path
|
||||
target for a specific path discovery."
|
||||
DEFVAL { 3 }
|
||||
::= { dot11MeshHWMPConfigEntry 1}
|
||||
|
||||
dot11MeshHWMPnetDiameter OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..255)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the estimate of the maximum number of
|
||||
hops that it takes for an HWMP element to propagate across the mesh
|
||||
BSS."
|
||||
DEFVAL { 31 }
|
||||
::= { dot11MeshHWMPConfigEntry 2}
|
||||
|
||||
dot11MeshHWMPnetDiameterTraversalTime OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the estimate of the interval of time
|
||||
(in TUs) that it takes for an HWMP element to propagate across the
|
||||
mesh BSS."
|
||||
DEFVAL { 500 }
|
||||
::= { dot11MeshHWMPConfigEntry 3}
|
||||
|
||||
dot11MeshHWMPpreqMinInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a mesh STA can send only one Action frame containing a
|
||||
PREQ element."
|
||||
DEFVAL { 100 }
|
||||
::= { dot11MeshHWMPConfigEntry 4}
|
||||
|
||||
dot11MeshHWMPperrMinInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a mesh STA can send only one Action frame containing a
|
||||
PERR element."
|
||||
DEFVAL { 100 }
|
||||
::= { dot11MeshHWMPConfigEntry 5}
|
||||
|
||||
dot11MeshHWMPactivePathToRootTimeout OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This object shall specify the time (in TUs) for which mesh STAs
|
||||
receiving a proactive PREQ shall consider the forwarding
|
||||
information to the root mesh STA to be valid; it must be greater
|
||||
than dot11MeshHWMProotInterval."
|
||||
DEFVAL { 5000 }
|
||||
::= { dot11MeshHWMPConfigEntry 6}
|
||||
|
||||
dot11MeshHWMPactivePathTimeout OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the time (in TUs) for which mesh STAs
|
||||
receiving a PREQ to individual target(s) shall consider the
|
||||
forwarding information to be valid."
|
||||
DEFVAL { 5000 }
|
||||
::= { dot11MeshHWMPConfigEntry 7}
|
||||
|
||||
dot11MeshHWMProotMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noRoot(0),
|
||||
proactivePREQnoPREP(2),
|
||||
proactivePREQwithPREP(3),
|
||||
rann(4)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute controls the configuration of a mesh STA as root
|
||||
mesh STA. A mesh STA is configured as a root mesh STA if
|
||||
dot11MeshHWMProotMode is set to 2, 3 or 4. Different values
|
||||
correspond to different modes of the root mesh STA. The mesh STA is
|
||||
not a root mesh STA when the attribute is set to 0."
|
||||
DEFVAL { noRoot }
|
||||
::= { dot11MeshHWMPConfigEntry 8}
|
||||
|
||||
dot11MeshHWMProotInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a root mesh STA can send only one Action frame
|
||||
containing a proactive PREQ element."
|
||||
DEFVAL { 2000 }
|
||||
::= { dot11MeshHWMPConfigEntry 9}
|
||||
|
||||
dot11MeshHWMPrannInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a mesh STA can send only one Action frame containing a
|
||||
RANN element."
|
||||
DEFVAL { 1000 }
|
||||
::= { dot11MeshHWMPConfigEntry 10}
|
||||
|
||||
dot11MeshHWMPtargetOnly OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
intermediateMSTA(0),
|
||||
targetOnly(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute, when set to intermediateMSTA (0), shall allow
|
||||
intermediate mesh STAs to respond with a PREP to a PREQ if they have
|
||||
valid forwarding information to the requested target. When set to
|
||||
targetOnly (1), only the target MSTA is allowed to respond with a
|
||||
PREP to a PREQ."
|
||||
DEFVAL { targetOnly }
|
||||
::= { dot11MeshHWMPConfigEntry 11}
|
||||
|
||||
dot11MeshHWMPmaintenanceInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a mesh STA can send only one Action frame containing a
|
||||
PREQ element for path maintenance."
|
||||
DEFVAL { 2000 }
|
||||
::= { dot11MeshHWMPConfigEntry 12}
|
||||
|
||||
dot11MeshHWMPconfirmationInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a control variable.
|
||||
It is written by an external management entity.
|
||||
This attribute shall specify the minimum interval of time (in TUs)
|
||||
during which a mesh STA can send only one Action frame containing a
|
||||
PREQ element for root path confirmation."
|
||||
DEFVAL { 2000 }
|
||||
::= { dot11MeshHWMPConfigEntry 13}
|
||||
|
||||
--**********************************************************************
|
||||
--* End of dot11MeshHWMPConfig TABLE
|
||||
--**********************************************************************
|
||||
|
||||
--**********************************************************************
|
||||
-- about conformance info
|
||||
--**********************************************************************
|
||||
fsDot11MeshHWMPConformance OBJECT IDENTIFIER ::= { fsDot11MeshHWMPMIB 2 }
|
||||
fsDot11MeshHWMPCompliances OBJECT IDENTIFIER ::= { fsDot11MeshHWMPConformance 1 }
|
||||
fsDot11MeshHWMPGroups OBJECT IDENTIFIER ::= { fsDot11MeshHWMPConformance 2 }
|
||||
|
||||
-- compliance statements
|
||||
fsDot11MeshHWMPCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for entities which implement the fsDot11MeshHWMPMIB."
|
||||
MODULE
|
||||
MANDATORY-GROUPS {
|
||||
fsDot11MeshHWMPGroup
|
||||
}
|
||||
::= {fsDot11MeshHWMPCompliances 1}
|
||||
-- units of conformance
|
||||
fsDot11MeshHWMPGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
dot11MeshHWMPmaxPREQretries,
|
||||
dot11MeshHWMPnetDiameter,
|
||||
dot11MeshHWMPnetDiameterTraversalTime,
|
||||
dot11MeshHWMPpreqMinInterval,
|
||||
dot11MeshHWMPperrMinInterval,
|
||||
dot11MeshHWMPactivePathToRootTimeout,
|
||||
dot11MeshHWMPactivePathTimeout,
|
||||
dot11MeshHWMProotMode,
|
||||
dot11MeshHWMProotInterval,
|
||||
dot11MeshHWMPrannInterval,
|
||||
dot11MeshHWMPtargetOnly,
|
||||
dot11MeshHWMPmaintenanceInterval,
|
||||
dot11MeshHWMPconfirmationInterval
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects which is possible for there to be
|
||||
multiple IEEE 802.11 interfaces on one agent, each with its
|
||||
unique MAC address. The relationship between an IEEE 802.11
|
||||
interface and an interface in the context of the Internet-standard
|
||||
MIB is one-to-one. As such, the value of an ifIndex object instance
|
||||
can be directly used to identify corresponding instances of the
|
||||
objects defined herein."
|
||||
::= { fsDot11MeshHWMPGroups 1 }
|
||||
END
|