initial commit; version 22.5.12042
This commit is contained in:
242
mibs/ericsson/RBN-ATM-PVC-OAM-MIB
Normal file
242
mibs/ericsson/RBN-ATM-PVC-OAM-MIB
Normal file
@ -0,0 +1,242 @@
|
||||
-- *****************************************************************
|
||||
-- RBN-ATM-PVC-OAM-MIB
|
||||
--
|
||||
-- Copyright (c) 2002 RedBack Networks, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
|
||||
RBN-ATM-PVC-OAM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
Integer32,
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP,
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
|
||||
rbnMgmt
|
||||
FROM RBN-SMI
|
||||
|
||||
RbnSlot, RbnPort
|
||||
FROM RBN-TC;
|
||||
|
||||
rbnAtmPvcOamMib MODULE-IDENTITY
|
||||
LAST-UPDATED "200211130000Z" -- November 13, 2002
|
||||
ORGANIZATION "Redback Networks, Inc."
|
||||
CONTACT-INFO
|
||||
" RedBack Networks, Inc.
|
||||
|
||||
Postal: 300 Holger Way
|
||||
San Jose, CA 95134
|
||||
USA
|
||||
|
||||
Phone: +1 408 750 5000
|
||||
Fax: +1 408 750 5599
|
||||
|
||||
E-mail: mib-info@redback.com
|
||||
"
|
||||
DESCRIPTION
|
||||
"Defines the objects required to monitor the ATM PVC OAM
|
||||
(Operation, Administration, and Maintenance) function.
|
||||
|
||||
The OAM functionality may be enabled on one or more ATM PVCs
|
||||
in a system. When this functionality is enabled on a given
|
||||
PVC, the system will periodically generate OAM F5 end-to-end
|
||||
loopback cells on the PVC. The primary goal of this function
|
||||
is to insure that an ATM PVC is brought down if the loss of
|
||||
network connectivity to the remote end is detected by the
|
||||
failure of the F5 OAM heartbeat cell. In addition, when this
|
||||
function is enabled on a PVC, receipt of an incoming F5 OAM
|
||||
VC-AIS (Virtual Circuit - Alarm Indication Signal) cell or
|
||||
F5 OAM VC-RDI (Virtual Circuit - Remote Detection Indicator)
|
||||
cell will also cause the associated PVC to be brought down.
|
||||
"
|
||||
|
||||
REVISION "200211130000Z" -- November 13, 2002
|
||||
DESCRIPTION
|
||||
"Replaced the SYNTAX of rbnAtmPvcOamStatusSlot and
|
||||
rbnAtmPvcOamStatusPort by the textual conventions RbnSlot
|
||||
and RbnPort, respectively. Updated CONTACT-INFO."
|
||||
|
||||
REVISION "200202050000Z" -- February 5, 2002
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
::= { rbnMgmt 19 }
|
||||
|
||||
rbnAtmPvcOamMibNotifications
|
||||
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 0 }
|
||||
|
||||
rbnAtmPvcOamMibObjects
|
||||
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 1 }
|
||||
|
||||
rbnAtmPvcOamMibConformance
|
||||
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMib 2 }
|
||||
|
||||
rbnAtmPvcOamStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnAtmPvcOamStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table which contains the status of the ATM PVC OAM
|
||||
function for every ATM PVC in the managed system. There
|
||||
will be one entry in this table for each ATM PVC active
|
||||
in the system, whether the PVC is statically configured
|
||||
or was created on-demand.
|
||||
"
|
||||
::= { rbnAtmPvcOamMibObjects 1 }
|
||||
|
||||
rbnAtmPvcOamStatusEntry OBJECT-TYPE
|
||||
SYNTAX RbnAtmPvcOamStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry which contains the status of the ATM PVC OAM
|
||||
function for a given ATM PVC.
|
||||
"
|
||||
INDEX {
|
||||
rbnAtmPvcOamStatusSlot,
|
||||
rbnAtmPvcOamStatusPort,
|
||||
rbnAtmPvcOamStatusVpi,
|
||||
rbnAtmPvcOamStatusVci
|
||||
}
|
||||
::= { rbnAtmPvcOamStatusTable 1 }
|
||||
|
||||
RbnAtmPvcOamStatusEntry ::= SEQUENCE {
|
||||
rbnAtmPvcOamStatusSlot RbnSlot,
|
||||
rbnAtmPvcOamStatusPort RbnPort,
|
||||
rbnAtmPvcOamStatusVpi Integer32,
|
||||
rbnAtmPvcOamStatusVci Integer32,
|
||||
rbnAtmPvcOamStatusState INTEGER
|
||||
}
|
||||
|
||||
rbnAtmPvcOamStatusSlot OBJECT-TYPE
|
||||
SYNTAX RbnSlot
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The slot containing the given ATM PVC."
|
||||
::= { rbnAtmPvcOamStatusEntry 1 }
|
||||
|
||||
rbnAtmPvcOamStatusPort OBJECT-TYPE
|
||||
SYNTAX RbnPort
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The port containing the given ATM PVC."
|
||||
::= { rbnAtmPvcOamStatusEntry 2 }
|
||||
|
||||
rbnAtmPvcOamStatusVpi OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..4095)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The VPI value of the given ATM PVC."
|
||||
::= { rbnAtmPvcOamStatusEntry 3 }
|
||||
|
||||
rbnAtmPvcOamStatusVci OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The VCI value of the given ATM PVC."
|
||||
::= { rbnAtmPvcOamStatusEntry 4 }
|
||||
|
||||
rbnAtmPvcOamStatusState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noOam (1),
|
||||
oamUp (2),
|
||||
oamDownLoopback (3),
|
||||
oamDownAis (4),
|
||||
oamDownRdi (5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The state of the ATM PVC OAM function on a given ATM PVC.
|
||||
|
||||
A value of noOam indicates the ATM PVC OAM function is not
|
||||
active on the given ATM PVC
|
||||
|
||||
A value of oamUp indicates the ATM PVC OAM function is
|
||||
active on the given ATM PVC and no failure condition is
|
||||
currently being detected on the circuit
|
||||
|
||||
A value of oamDownLoopback indicates the ATM PVC OAM function is
|
||||
active on the given ATM PVC and F5 OAM loopback cell management
|
||||
has detected a fault on the circuit
|
||||
|
||||
A value of oamDownAis indicates the ATM PVC OAM function is
|
||||
active on the given ATM PVC and a VC-AIS cell was recently
|
||||
received which indicates a fault on the circuit
|
||||
|
||||
A value of oamDownRdi indicates the ATM PVC OAM function is
|
||||
active on the given ATM PVC and a VC-RDI cell was recently
|
||||
received which indicates a fault on the circuit
|
||||
"
|
||||
::= { rbnAtmPvcOamStatusEntry 5 }
|
||||
|
||||
--
|
||||
-- notifications
|
||||
--
|
||||
|
||||
rbnAtmPvcOamStatusStateChange NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
rbnAtmPvcOamStatusState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A notification indicating that the state of an ATM PVC has
|
||||
transitioned as a result of the ATM PVC OAM function. This
|
||||
notification will be sent if the value of rbnAtmPvcOamStatusState
|
||||
transitions from oamUp to any of the three oamDown values, or if
|
||||
it transitions from any of the three oamDown values to oamUp.
|
||||
"
|
||||
::= { rbnAtmPvcOamMibNotifications 1 }
|
||||
|
||||
--
|
||||
-- compliance statements
|
||||
--
|
||||
rbnAtmPvcOamCompliances
|
||||
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMibConformance 1 }
|
||||
rbnAtmPvcOamGroups
|
||||
OBJECT IDENTIFIER ::= { rbnAtmPvcOamMibConformance 2 }
|
||||
|
||||
rbnAtmPvcOamCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP entities which implement
|
||||
the Redback ATM PVC OAM MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
rbnAtmPvcOamGroup,
|
||||
rbnAtmPvcOamNotifyGroup
|
||||
}
|
||||
::= { rbnAtmPvcOamCompliances 1 }
|
||||
|
||||
rbnAtmPvcOamGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rbnAtmPvcOamStatusState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects which allow monitoring of the
|
||||
ATM PVC OAM function."
|
||||
::= { rbnAtmPvcOamGroups 1 }
|
||||
|
||||
rbnAtmPvcOamNotifyGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
rbnAtmPvcOamStatusStateChange
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of notifications which allow monitoring of the
|
||||
ATM PVC OAM function."
|
||||
::= { rbnAtmPvcOamGroups 2 }
|
||||
|
||||
END
|