EATON-GENESIS-II-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
enterprises FROM RFC1155-SMI
|
||||
DisplayString FROM RFC1213-MIB
|
||||
OBJECT-TYPE FROM RFC-1212
|
||||
TRAP-TYPE FROM RFC-1215;
|
||||
|
||||
eaton OBJECT IDENTIFIER ::= { enterprises 17373 }
|
||||
|
||||
genesis2 OBJECT IDENTIFIER ::= { eaton 3 }
|
||||
productInfo OBJECT IDENTIFIER ::= { genesis2 1 }
|
||||
sensorData OBJECT IDENTIFIER ::= { genesis2 2 }
|
||||
|
||||
|
||||
|
||||
productTitle OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Name of product"
|
||||
::= { productInfo 1 }
|
||||
|
||||
productVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Firmware version"
|
||||
::= { productInfo 2 }
|
||||
|
||||
productName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Unit friendly name"
|
||||
::= { productInfo 3 }
|
||||
|
||||
productMAC OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Unit MAC address"
|
||||
::= { productInfo 4 }
|
||||
|
||||
productIP OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"IP address of the unit"
|
||||
::= { productInfo 5 }
|
||||
|
||||
|
||||
|
||||
intDeciAmpsCT1 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT1 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 1 }
|
||||
|
||||
intDeciAmpsCT2 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT2 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 2 }
|
||||
|
||||
intDeciAmpsCT3 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT3 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 3 }
|
||||
|
||||
intDeciAmpsCT4 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT4 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 4 }
|
||||
|
||||
intDeciAmpsCT5 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT5 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 5 }
|
||||
|
||||
intDeciAmpsCT6 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT6 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 6 }
|
||||
|
||||
intDeciAmpsCT7 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT7 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 7 }
|
||||
|
||||
intDeciAmpsCT8 OBJECT-TYPE
|
||||
SYNTAX INTEGER(-1..300)
|
||||
UNITS "0.1 Amps"
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Current Reading from CT8 in deci-Amps, a reading of -1
|
||||
means the CT is unavailable on this unit"
|
||||
::= { sensorData 8 }
|
||||
|
||||
|
||||
|
||||
intDeciAmpsCT1TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT1 }
|
||||
DESCRIPTION "DeciAmps CT1 Trap"
|
||||
::= 1
|
||||
|
||||
intDeciAmpsCT2TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT2 }
|
||||
DESCRIPTION "DeciAmps CT2 Trap"
|
||||
::= 2
|
||||
|
||||
intDeciAmpsCT3TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT3 }
|
||||
DESCRIPTION "DeciAmps CT3 Trap"
|
||||
::= 3
|
||||
|
||||
intDeciAmpsCT4TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT4 }
|
||||
DESCRIPTION "DeciAmps CT4 Trap"
|
||||
::= 4
|
||||
|
||||
intDeciAmpsCT5TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT5 }
|
||||
DESCRIPTION "DeciAmps CT5 Trap"
|
||||
::= 5
|
||||
|
||||
intDeciAmpsCT6TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT6 }
|
||||
DESCRIPTION "DeciAmps CT6 Trap"
|
||||
::= 6
|
||||
|
||||
intDeciAmpsCT7TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT7 }
|
||||
DESCRIPTION "DeciAmps CT7 Trap"
|
||||
::= 7
|
||||
|
||||
intDeciAmpsCT8TRAP TRAP-TYPE
|
||||
ENTERPRISE eaton
|
||||
VARIABLES { intDeciAmpsCT8 }
|
||||
DESCRIPTION "DeciAmps CT8 Trap"
|
||||
::= 8
|
||||
|
||||
|
||||
|
||||
END
|