initial commit; version 22.5.12042
This commit is contained in:
360
mibs/d-link/DLINK-EQUIPMENT-MIB
Normal file
360
mibs/d-link/DLINK-EQUIPMENT-MIB
Normal file
@ -0,0 +1,360 @@
|
||||
-- 0.9 Draft
|
||||
-- 2003/1/21 11:21AM
|
||||
-- Create DLINK-EQUIPMENT-MIB
|
||||
-- equipment :
|
||||
-- fan , power , unit(stacking or chassis), temperature
|
||||
-- include traps for related equipment
|
||||
-- *****************************************************************************
|
||||
|
||||
|
||||
DLINK-EQUIPMENT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
DateAndTime, TruthValue ,DisplayString
|
||||
FROM SNMPv2-TC
|
||||
AgentNotifyLevel, dlink-common-mgmt
|
||||
FROM DLINK-ID-REC-MIB;
|
||||
|
||||
|
||||
swDlinkEquipmentMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "0202140000Z"
|
||||
ORGANIZATION "DLink Corporation"
|
||||
CONTACT-INFO
|
||||
""
|
||||
DESCRIPTION
|
||||
"DLink equipments MIB ."
|
||||
::= { dlink-common-mgmt 11 }
|
||||
|
||||
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address
|
||||
-- in the
|
||||
-- "canonical"
|
||||
-- order, copy from RFC1493
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- OID Tree Allocation
|
||||
--
|
||||
swDlinkEquipmentMib OBJECT IDENTIFIER ::= { swDlinkEquipmentMIB 1 }
|
||||
swDlinkEquipmentNotify OBJECT IDENTIFIER ::= { swDlinkEquipmentMIB 2 }
|
||||
|
||||
--
|
||||
-- Object Definition
|
||||
--
|
||||
|
||||
|
||||
swDlinkEquipmentCapacity OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
fanCapable(0),
|
||||
--
|
||||
redundantPowerCapable(1),
|
||||
--
|
||||
tempteratureDetection(2),
|
||||
stackingCapable(3),
|
||||
chassisCapable(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the equipment capacity supported in the system
|
||||
."
|
||||
|
||||
::= { swDlinkEquipmentMib 1 }
|
||||
|
||||
|
||||
-- *****************************************************************************
|
||||
|
||||
swPowerTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SwPowerEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A list of temperature."
|
||||
::= { swDlinkEquipmentMib 6 }
|
||||
|
||||
swPowerEntry OBJECT-TYPE
|
||||
SYNTAX SwPowerEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A entry of Power information."
|
||||
INDEX { swPowerUnitIndex,swPowerID }
|
||||
::= { swPowerTable 1 }
|
||||
|
||||
SwPowerEntry ::= SEQUENCE {
|
||||
swPowerUnitIndex INTEGER,
|
||||
swPowerID INTEGER,
|
||||
swPowerStatus INTEGER
|
||||
}
|
||||
|
||||
swPowerUnitIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates ID of the unit in the System"
|
||||
::= { swPowerEntry 1 }
|
||||
swPowerID OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates ID of the power
|
||||
1 : main power
|
||||
2 : redundant power ."
|
||||
::= { swPowerEntry 2 }
|
||||
|
||||
swPowerStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(0),
|
||||
lowVoltage(1),
|
||||
overCurrent(2),
|
||||
working(3),
|
||||
fail(4),
|
||||
connect(5),
|
||||
disconnect(6)
|
||||
}
|
||||
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates status of the power "
|
||||
::= { swPowerEntry 3 }
|
||||
|
||||
-- *****************************************************************************
|
||||
|
||||
-- swFanTable := { swDlinkEquipmentMib 7 }
|
||||
-- swTemperatureTable := { swDlinkEquipmentMib 8 }
|
||||
|
||||
-- *****************************************************************************
|
||||
swUnitMgmt OBJECT IDENTIFIER ::= { swDlinkEquipmentMib 9 }
|
||||
|
||||
|
||||
swUnitStackingVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the version of this stacking system ."
|
||||
::= { swUnitMgmt 1 }
|
||||
|
||||
swUnitMaxSupportedUnits OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum number of units are supported in the system."
|
||||
::= { swUnitMgmt 2 }
|
||||
|
||||
swUnitNumOfUnit OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current number of units."
|
||||
::= { swUnitMgmt 3 }
|
||||
|
||||
swUnitMgmtTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SwUnitMgmtEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains the unit information."
|
||||
::= { swUnitMgmt 4 }
|
||||
|
||||
swUnitMgmtEntry OBJECT-TYPE
|
||||
SYNTAX SwUnitMgmtEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of management information for each unit in the system."
|
||||
INDEX { swUnitMgmtId }
|
||||
::= { swUnitMgmtTable 1 }
|
||||
|
||||
SwUnitMgmtEntry ::=
|
||||
SEQUENCE {
|
||||
swUnitMgmtId
|
||||
INTEGER,
|
||||
swUnitMgmtMacAddr
|
||||
MacAddress,
|
||||
swUnitMgmtStartPort
|
||||
INTEGER,
|
||||
swUnitMgmtPortRange
|
||||
INTEGER,
|
||||
swUnitMgmtFrontPanelLedStatus
|
||||
OCTET STRING,
|
||||
swUnitMgmtCtrlMode
|
||||
INTEGER,
|
||||
swUnitMgmtCurrentMode
|
||||
INTEGER,
|
||||
swUnitMgmtVersion
|
||||
DisplayString,
|
||||
swUnitMgmtModuleName
|
||||
DisplayString
|
||||
}
|
||||
|
||||
swUnitMgmtId OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..15)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the specific entry in the stacking/chassis
|
||||
table."
|
||||
::= { swUnitMgmtEntry 1 }
|
||||
|
||||
swUnitMgmtMacAddr OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Mac address of this unit."
|
||||
::= { swUnitMgmtEntry 2 }
|
||||
|
||||
swUnitMgmtStartPort OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the start port of this unit."
|
||||
::= { swUnitMgmtEntry 3 }
|
||||
|
||||
swUnitMgmtPortRange OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the total ports of this unit."
|
||||
::= { swUnitMgmtEntry 4 }
|
||||
|
||||
swUnitMgmtFrontPanelLedStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is a set of system LED indications. The first three
|
||||
octets is defined as system LED. The first LED is power LED. The
|
||||
second LED is console LED. The third LED is RPS (Redundancy
|
||||
Power Supply) LED. The other octets following the second
|
||||
octets are the logical port LED (following dot1dBasePort
|
||||
ordering). One byte is presented to one port and
|
||||
this byte is presentd to the Link/Activity LED.
|
||||
|
||||
Link/Activity LED :
|
||||
The most significant bit is used for blink/solid:
|
||||
8 = The LED blinks.
|
||||
|
||||
The second significant bit is used for link status:
|
||||
1 = link fail.
|
||||
2 = link pass.
|
||||
|
||||
The four remaining bits are currently unused and must be 0."
|
||||
::= { swUnitMgmtEntry 5 }
|
||||
|
||||
|
||||
swUnitMgmtCtrlMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
auto(2),
|
||||
stand-alone(3),
|
||||
master(4),
|
||||
slave(5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the stack mode that user configed for
|
||||
this unit. The object only can be configed when the device is
|
||||
stand alone.
|
||||
|
||||
other(1) - this entry is currently in use but the conditions
|
||||
under which it will remain so are different from each of the
|
||||
following values.
|
||||
auto(2) - the system will auto assign this stack role of this
|
||||
unit to be stand-alone(3), master(4), or slave(5).
|
||||
stand-alone(3) - the unit is forced to stand alone.
|
||||
master(4) - the unit is forced to master. If this unit is
|
||||
seleted to be master, it can modify the configuration of the
|
||||
stacking system.
|
||||
slave(5) - the unit is forced to slave. If this unit is
|
||||
seleted to be slave, it only can view the configuration of
|
||||
the stacking system."
|
||||
::= { swUnitMgmtEntry 6 }
|
||||
|
||||
swUnitMgmtCurrentMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
auto(2),
|
||||
stand-alone(3),
|
||||
master(4),
|
||||
slave(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current stack role of this unit."
|
||||
::= { swUnitMgmtEntry 7 }
|
||||
|
||||
swUnitMgmtVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the version of this stacking unit."
|
||||
::= { swUnitMgmtEntry 8 }
|
||||
|
||||
swUnitMgmtModuleName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual string containing module name of the
|
||||
stacking unit. "
|
||||
::= { swUnitMgmtEntry 9 }
|
||||
|
||||
|
||||
|
||||
-- *****************************************************************************
|
||||
|
||||
--swEquipmentNotifyMgmt OBJECT IDENTIFIER ::= { swDlinkEquipmentNotify 1 }
|
||||
swEquipmentNotification OBJECT IDENTIFIER ::= { swDlinkEquipmentNotify 2 }
|
||||
|
||||
|
||||
--swEquipUnitNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 1 }
|
||||
swEquipPowerNotification OBJECT IDENTIFIER ::= { swEquipmentNotification 2 }
|
||||
|
||||
|
||||
|
||||
-- *****************************************************************************
|
||||
-- *****************************************************************************
|
||||
--swEquipUnitNotifyPrefix OBJECT IDENTIFIER ::= { swEquipUnitNotification 0 }
|
||||
|
||||
-- *****************************************************************************
|
||||
|
||||
swEquipPowerNotifyPerfix OBJECT IDENTIFIER ::= { swEquipPowerNotification 0 }
|
||||
|
||||
swPowerFailure NOTIFICATION-TYPE
|
||||
OBJECTS { swPowerUnitIndex,
|
||||
swPowerID,
|
||||
swPowerStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Power Failure notification."
|
||||
::= { swEquipPowerNotifyPerfix 2 }
|
||||
|
||||
swPowerRecover NOTIFICATION-TYPE
|
||||
OBJECTS {swPowerUnitIndex,
|
||||
swPowerID,
|
||||
swPowerStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Power Recover notification."
|
||||
::= { swEquipPowerNotifyPerfix 3 }
|
||||
|
||||
|
||||
-- *****************************************************************************
|
||||
|
||||
swNotificationBindings OBJECT IDENTIFIER ::= { swDlinkEquipmentNotify 3 }
|
||||
|
||||
|
||||
|
||||
END
|
Reference in New Issue
Block a user