initial commit; version 22.5.12042
This commit is contained in:
899
mibs/commend/COMMEND-SIP-MIB
Normal file
899
mibs/commend/COMMEND-SIP-MIB
Normal file
@ -0,0 +1,899 @@
|
||||
COMMEND-SIP-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
Integer32,
|
||||
enterprises FROM SNMPv2-SMI;
|
||||
|
||||
commend MODULE-IDENTITY
|
||||
LAST-UPDATED "201205160000Z"
|
||||
ORGANIZATION "Commend International GmbH"
|
||||
CONTACT-INFO "Commend International GmbH"
|
||||
DESCRIPTION
|
||||
"MIB for Commend SIP Terminals"
|
||||
REVISION "201205160000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision"
|
||||
::= { enterprises 37568 }
|
||||
|
||||
commendStationObjects OBJECT IDENTIFIER ::= { commend 2 }
|
||||
|
||||
commendStationObjectEntry OBJECT IDENTIFIER ::= { commendStationObjects 1 }
|
||||
|
||||
commendStationObjectStatusNotifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status Notifications"
|
||||
::= {commendStationObjects 10 }
|
||||
|
||||
commendStationApplicationStart NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Application started"
|
||||
::= {commendStationObjects 20 }
|
||||
|
||||
commendStationCommon OBJECT IDENTIFIER ::= {commendStationObjectEntry 1 }
|
||||
|
||||
commendStationCommonStationType OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Station Type"
|
||||
::= { commendStationCommon 1 }
|
||||
|
||||
commendStationCommonStationSubType OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Station Subtype"
|
||||
::= { commendStationCommon 2 }
|
||||
|
||||
commendStationCommonStationSoftwareVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Software Version"
|
||||
::= { commendStationCommon 3 }
|
||||
|
||||
commendStationCommonStationHardwareVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Hardware Version"
|
||||
::= { commendStationCommon 4 }
|
||||
|
||||
commendStationCommonStationCallNumber OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System Call Number"
|
||||
::= { commendStationCommon 10 }
|
||||
|
||||
commendStationCommonStationStationName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System StationName"
|
||||
::= { commendStationCommon 11 }
|
||||
|
||||
commendStationCommonStationLocation OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Flash Config Location"
|
||||
::= { commendStationCommon 12 }
|
||||
|
||||
commendStationCommonStationSystemState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationCommon 20 }
|
||||
|
||||
commendStationCommonStationNtpState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"NTP synchronization state"
|
||||
::= { commendStationCommon 25 }
|
||||
|
||||
commendStationCommonStationNtpNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"NTP synchronization notification"
|
||||
::= {commendStationCommon 26 }
|
||||
|
||||
commendStationCommonStationSequenceName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System Sequence Name"
|
||||
::= { commendStationCommon 30 }
|
||||
|
||||
commendStationCommonStationCallState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationCommon 80 }
|
||||
|
||||
commendStationConnectivity OBJECT IDENTIFIER ::= {commendStationObjectEntry 2 }
|
||||
|
||||
commendStationConnectivityType OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationConnectivity 1 }
|
||||
|
||||
commendStationConnectivityAnalog OBJECT IDENTIFIER ::= {commendStationConnectivity 2 }
|
||||
commendStationConnectivityDigital OBJECT IDENTIFIER ::= {commendStationConnectivity 3 }
|
||||
commendStationConnectivityIp OBJECT IDENTIFIER ::= {commendStationConnectivity 4 }
|
||||
commendStationConnectivitySip OBJECT IDENTIFIER ::= {commendStationConnectivity 5 }
|
||||
|
||||
commendStationConnectivitySipPrimaryRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Registration State"
|
||||
::= { commendStationConnectivitySip 1 }
|
||||
|
||||
commendStationConnectivitySipPrimaryLastRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Last Registration"
|
||||
::= { commendStationConnectivitySip 2 }
|
||||
|
||||
commendStationConnectivitySipDhcp OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationConnectivitySip 3 }
|
||||
|
||||
commendStationConnectivitySipDns OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationConnectivitySip 4 }
|
||||
|
||||
commendStationConnectivitySipAccount OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationConnectivitySip 5 }
|
||||
|
||||
commendStationConnectivitySipAccountTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AccountTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about all
|
||||
configured sip accounts on this device."
|
||||
::= { commendStationConnectivitySip 40 }
|
||||
|
||||
accountTableEntry OBJECT-TYPE
|
||||
SYNTAX AccountTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row describing a given sip account table entry."
|
||||
INDEX { accountNumber }
|
||||
::= {commendStationConnectivitySipAccountTable 1 }
|
||||
|
||||
AccountTableEntry ::= SEQUENCE {
|
||||
accountNumber OCTET STRING,
|
||||
accountDisplayName OCTET STRING,
|
||||
accountUserId OCTET STRING,
|
||||
accountServer OCTET STRING,
|
||||
accountState OCTET STRING
|
||||
}
|
||||
|
||||
accountNumber OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Internal account ID."
|
||||
::= { accountTableEntry 1 }
|
||||
|
||||
accountDisplayName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SIP Display Name."
|
||||
::= { accountTableEntry 2 }
|
||||
|
||||
accountUserId OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User name used for SIP registration."
|
||||
::= { accountTableEntry 3 }
|
||||
|
||||
accountServer OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SIP server address"
|
||||
::= { accountTableEntry 4 }
|
||||
|
||||
accountState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Registration state of SIP account"
|
||||
::= { accountTableEntry 5 }
|
||||
|
||||
commendStationConnectivitySipSecondaryRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Registration State"
|
||||
::= { commendStationConnectivitySip 10 }
|
||||
commendStationConnectivitySipSecondaryLastRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Last Registration"
|
||||
::= { commendStationConnectivitySip 11 }
|
||||
commendStationConnectivitySipTertiaryRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Registration State"
|
||||
::= { commendStationConnectivitySip 20 }
|
||||
commendStationConnectivitySipTertiaryLastRegistration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Last Registration"
|
||||
::= { commendStationConnectivitySip 21 }
|
||||
|
||||
|
||||
commendStationAudio OBJECT IDENTIFIER ::= {commendStationObjectEntry 3 }
|
||||
commendStationAudioMic1 OBJECT IDENTIFIER ::= {commendStationAudio 1 }
|
||||
commendStationAudioMic2 OBJECT IDENTIFIER ::= {commendStationAudio 2 }
|
||||
commendStationAudioMic3 OBJECT IDENTIFIER ::= {commendStationAudio 3 }
|
||||
commendStationAudioLsMic OBJECT IDENTIFIER ::= {commendStationAudio 4 }
|
||||
commendStationAudiomonitoring OBJECT IDENTIFIER ::= {commendStationAudio 5 }
|
||||
|
||||
commendStationAudioLsMicStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"LS/Mic Surveillance Status"
|
||||
::= { commendStationAudioLsMic 1 }
|
||||
|
||||
commendStationAudiomonitoringStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Audiomonitoring Status"
|
||||
::= { commendStationAudiomonitoring 1 }
|
||||
|
||||
commendStationAudioMic1Type OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Microphonetype"
|
||||
::= { commendStationAudioMic1 1 }
|
||||
|
||||
commendStationAudioMic1Sensitivity OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Microphone Sensitivity"
|
||||
::= { commendStationAudioMic1 2 }
|
||||
|
||||
commendStationAudioAmp1 OBJECT IDENTIFIER ::= {commendStationAudio 10 }
|
||||
|
||||
commendStationAudioAmp1Type OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Amplifiertype"
|
||||
::= { commendStationAudioAmp1 1 }
|
||||
|
||||
commendStationAudioAmp1Sensitivity OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Amplifier Sensitivity"
|
||||
::= { commendStationAudioAmp1 2 }
|
||||
|
||||
|
||||
commendStationAudioSpeakerCompressor OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Compressor Level"
|
||||
::= { commendStationAudioAmp1 3 }
|
||||
|
||||
commendStationAudioLsMicSurveillanceNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Ls/Mic Surveillance Notification"
|
||||
::= {commendStationAudio 11 }
|
||||
|
||||
commendStationAudioMonitoringAlarmNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Audio Monitoring Alarm Notification"
|
||||
::= {commendStationAudio 12 }
|
||||
|
||||
commendStationAudioAEC OBJECT IDENTIFIER ::= {commendStationAudio 50 }
|
||||
commendStationAudioAECMode OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Adaptive Echo Canceller Mode"
|
||||
::= { commendStationAudioAEC 1 }
|
||||
|
||||
commendStationAudioNgClosedGain OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Noise Gate Closed Gain"
|
||||
::= { commendStationAudioAEC 2 }
|
||||
|
||||
commendStationAudioPgClosedGain OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Switched Duplex Closed Gain"
|
||||
::= { commendStationAudioAEC 3 }
|
||||
|
||||
commendStationAudioNgEnabled OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Noise Gate Enabled"
|
||||
::= { commendStationAudioAEC 4 }
|
||||
|
||||
commendStationAudioPgEnabled OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Switched Duplex Enabled"
|
||||
::= { commendStationAudioAEC 5 }
|
||||
|
||||
commendStationAudioNC OBJECT IDENTIFIER ::= {commendStationAudio 51 }
|
||||
commendStationAudioNCMode OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Noise Canceller Mode"
|
||||
::= { commendStationAudioNC 1 }
|
||||
|
||||
commendStationInputs OBJECT IDENTIFIER ::= {commendStationObjectEntry 4 }
|
||||
|
||||
commendStationInputNotifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Input Status Notifications"
|
||||
::= {commendStationInputs 9 }
|
||||
|
||||
commendStationInputButtonStuckNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Input Button Stuck Notifications"
|
||||
::= {commendStationInputNotifications 1 }
|
||||
|
||||
commendStationInputHandsetOffhookNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Handset Offhook Notifications"
|
||||
::= {commendStationInputNotifications 2 }
|
||||
|
||||
commendStationInputChangedNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Input Changed Notifications"
|
||||
::= {commendStationInputNotifications 3 }
|
||||
|
||||
commendStationInput1 OBJECT IDENTIFIER ::= {commendStationInputs 1 }
|
||||
|
||||
commendStationInput2 OBJECT IDENTIFIER ::= {commendStationInputs 2 }
|
||||
|
||||
commendStationInput3 OBJECT IDENTIFIER ::= {commendStationInputs 3 }
|
||||
|
||||
commendStationEB2E2AInput1 OBJECT IDENTIFIER ::= {commendStationInputs 4 }
|
||||
|
||||
commendStationEB2E2AInput2 OBJECT IDENTIFIER ::= {commendStationInputs 5 }
|
||||
|
||||
commendStationInputKeyboard OBJECT IDENTIFIER ::= {commendStationInputs 10 }
|
||||
|
||||
commendStationInputStatus OBJECT IDENTIFIER ::= {commendStationObjectEntry 5}
|
||||
|
||||
commendStationLastInputChange OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Last input changed information"
|
||||
::= { commendStationInputStatus 1 }
|
||||
|
||||
commendStationLastButtonStuck OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputStatus 2 }
|
||||
|
||||
commendStationInputKeyboardButton1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputKeyboard 1 }
|
||||
|
||||
commendStationInputKeyboardButton2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputKeyboard 2 }
|
||||
|
||||
commendStationInputKeyboardButton3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputKeyboard 3 }
|
||||
|
||||
commendStationInputFullKeyboard OBJECT IDENTIFIER ::= {commendStationInputs 11 }
|
||||
|
||||
commendStationInputFullKeyboardButton1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 1 }
|
||||
|
||||
commendStationInputFullKeyboardButton2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 2 }
|
||||
|
||||
commendStationInputFullKeyboardButton3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 3 }
|
||||
|
||||
commendStationInputFullKeyboardButton4 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 4 }
|
||||
|
||||
commendStationInputFullKeyboardButton5 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 5 }
|
||||
|
||||
commendStationInputFullKeyboardButton6 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 6 }
|
||||
|
||||
commendStationInputFullKeyboardButton7 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 7 }
|
||||
|
||||
commendStationInputFullKeyboardButton8 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 8 }
|
||||
|
||||
commendStationInputFullKeyboardButton9 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 9 }
|
||||
|
||||
commendStationInputFullKeyboardButton0 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 10 }
|
||||
|
||||
commendStationInputFullKeyboardButtonX OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 11 }
|
||||
|
||||
commendStationInputFullKeyboardButtonT OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 12 }
|
||||
|
||||
commendStationInputFullKeyboardButtonUP OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 13 }
|
||||
|
||||
commendStationInputFullKeyboardButtonDOWN OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 14 }
|
||||
|
||||
commendStationInputFullKeyboardButtonMENU OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 15 }
|
||||
|
||||
commendStationInputFullKeyboardButtonENTER OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInputFullKeyboard 16 }
|
||||
|
||||
commendStationInputType1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput1 1 }
|
||||
|
||||
commendStationInputState1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput1 2 }
|
||||
|
||||
commendStationInputType2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput2 1 }
|
||||
|
||||
commendStationInputState2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput2 2 }
|
||||
|
||||
commendStationInputType3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput3 1 }
|
||||
|
||||
commendStationInputState3 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationInput3 2 }
|
||||
|
||||
commendStationEB2E2AInputType1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AInput1 1 }
|
||||
|
||||
commendStationEB2E2AInputState1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AInput1 2 }
|
||||
|
||||
commendStationEB2E2AInputType2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AInput2 1 }
|
||||
|
||||
commendStationEB2E2AInputState2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AInput2 2 }
|
||||
|
||||
commendStationInputTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF InputTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about all inputs."
|
||||
::= { commendStationInputs 20 }
|
||||
|
||||
inputTableEntry OBJECT-TYPE
|
||||
SYNTAX AccountTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row describing a given input"
|
||||
INDEX { inputName }
|
||||
::= {commendStationInputTable 1 }
|
||||
|
||||
InputTableEntry ::= SEQUENCE {
|
||||
inputName OCTET STRING,
|
||||
inputState OCTET STRING
|
||||
}
|
||||
|
||||
inputName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Input name <product-id><serial-number><input number>."
|
||||
::= { inputTableEntry 1 }
|
||||
|
||||
inputState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"State of the given input."
|
||||
::= { inputTableEntry 2 }
|
||||
|
||||
commendStationOutputs OBJECT IDENTIFIER ::= {commendStationObjectEntry 5 }
|
||||
|
||||
commendStationOutput1 OBJECT IDENTIFIER ::= {commendStationOutputs 1 }
|
||||
|
||||
commendStationOutput2 OBJECT IDENTIFIER ::= {commendStationOutputs 2 }
|
||||
|
||||
commendStationEB2E2AOutput1 OBJECT IDENTIFIER ::= {commendStationOutputs 3 }
|
||||
|
||||
commendStationEB2E2AOutput2 OBJECT IDENTIFIER ::= {commendStationOutputs 4 }
|
||||
|
||||
commendStationOutputNotifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Status Notifications"
|
||||
::= {commendStationOutputs 9 }
|
||||
|
||||
commendStationOutputChangedNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Changed Notifications"
|
||||
::= {commendStationOutputNotifications 1 }
|
||||
|
||||
commendStationOutput1Notifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Status Notifications"
|
||||
::= {commendStationOutput1 10 }
|
||||
|
||||
commendStationOutput2Notifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Status Notifications"
|
||||
::= {commendStationOutput2 10 }
|
||||
|
||||
commendStationEB2E2AOutput1Notifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Status Notifications"
|
||||
::= {commendStationEB2E2AOutput1 10 }
|
||||
|
||||
commendStationEB2E2AOutput2Notifications NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output Status Notifications"
|
||||
::= {commendStationEB2E2AOutput2 10 }
|
||||
|
||||
commendStationOutputName1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationOutput1 1 }
|
||||
|
||||
commendStationOutputState1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationOutput1 2 }
|
||||
|
||||
commendStationOutputName2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationOutput2 1 }
|
||||
|
||||
commendStationOutputState2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationOutput2 2 }
|
||||
|
||||
commendStationEB2E2AOutputName1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AOutput1 1 }
|
||||
|
||||
commendStationEB2E2AOutputState1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AOutput1 2 }
|
||||
|
||||
commendStationEB2E2AOutputName2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AOutput2 1 }
|
||||
|
||||
commendStationEB2E2AOutputState2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { commendStationEB2E2AOutput2 2 }
|
||||
|
||||
commendStationOutputTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF OutputTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about all outputs."
|
||||
::= { commendStationOutputs 20 }
|
||||
|
||||
outputTableEntry OBJECT-TYPE
|
||||
SYNTAX AccountTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row describing a given output"
|
||||
INDEX { outputName }
|
||||
::= {commendStationOutputTable 1 }
|
||||
|
||||
OutputTableEntry ::= SEQUENCE {
|
||||
outputName OCTET STRING,
|
||||
outputState OCTET STRING
|
||||
}
|
||||
|
||||
outputName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output name <product-id><serial-number><output number>."
|
||||
::= { outputTableEntry 1 }
|
||||
|
||||
|
||||
outputState OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output state."
|
||||
::= { outputTableEntry 2 }
|
||||
|
||||
commendStationOutputStatus OBJECT IDENTIFIER ::= {commendStationObjectEntry 7}
|
||||
|
||||
commendStationLastOutputChange OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(0..1024))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Last output changed"
|
||||
::= { commendStationOutputStatus 1 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user