-- MIB table for H3531
|
||||
--
|
||||
-- v1.0 for firmware 9-5-0-0, 2017-04-19
|
||||
-----------------------------------------------------------------------
|
||||
H3531-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
|
||||
IMPORTS
|
||||
enterprises
|
||||
FROM RFC1155-SMI
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212
|
||||
TRAP-TYPE
|
||||
FROM RFC-1215;
|
||||
|
||||
DisplayString ::= OCTET STRING
|
||||
|
||||
|
||||
comet OBJECT IDENTIFIER ::= { enterprises 22626 }
|
||||
products OBJECT IDENTIFIER ::= { comet 1 }
|
||||
h3531 OBJECT IDENTIFIER ::= { products 2 }
|
||||
values OBJECT IDENTIFIER ::= { h3531 1 }
|
||||
global OBJECT IDENTIFIER ::= { h3531 2 }
|
||||
valuesInt OBJECT IDENTIFIER ::= { h3531 3 }
|
||||
settings OBJECT IDENTIFIER ::= { h3531 4 }
|
||||
traps OBJECT IDENTIFIER ::= { h3531 5 }
|
||||
tables OBJECT IDENTIFIER ::= { h3531 6 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Measured values - String
|
||||
-----------------------------------------------------------------------
|
||||
temp OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature"
|
||||
::= { values 1 }
|
||||
|
||||
hum OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relative humidity"
|
||||
::= { values 2 }
|
||||
|
||||
compVal OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value"
|
||||
::= { values 3 }
|
||||
|
||||
bin1 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 1 state; 0 state description, 1 state description"
|
||||
::= { values 5 }
|
||||
|
||||
bin2 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 2 state; 0 state description, 1 state description"
|
||||
::= { values 6 }
|
||||
|
||||
bin3 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 3 state; 0 state description, 1 state description"
|
||||
::= { values 7 }
|
||||
|
||||
re1 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relay 1 state; open, closed"
|
||||
::= { values 8 }
|
||||
|
||||
re2 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relay 2 state; open, closed"
|
||||
::= { values 9 }
|
||||
|
||||
tempAlarm1 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Temperature; none, active"
|
||||
::= { values 10 }
|
||||
|
||||
humAlarm1 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Relative humidity; none, active"
|
||||
::= { values 11 }
|
||||
|
||||
compValAlarm1 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Computed value; none, active"
|
||||
::= { values 12 }
|
||||
|
||||
tempAlarm2 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Temperature; none, active"
|
||||
::= { values 14 }
|
||||
|
||||
humAlarm2 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Relative humidity; none, active"
|
||||
::= { values 15 }
|
||||
|
||||
compValAlarm2 OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Computed value; none, active"
|
||||
::= { values 16 }
|
||||
|
||||
bin1Alarm OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 1; none, active"
|
||||
::= { values 18 }
|
||||
|
||||
bin2Alarm OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 2; none, active"
|
||||
::= { values 19 }
|
||||
|
||||
bin3Alarm OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 3; none, active"
|
||||
::= { values 20 }
|
||||
|
||||
tempUnit OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Unit"
|
||||
::= { values 21 }
|
||||
|
||||
humUnit OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relative humidity Unit"
|
||||
::= { values 22 }
|
||||
|
||||
compValUnit OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..8))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Unit"
|
||||
::= { values 23 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Device informations
|
||||
-----------------------------------------------------------------------
|
||||
sensorName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..68))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Device name"
|
||||
::= { global 1 }
|
||||
|
||||
serialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..16))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Serial number"
|
||||
::= { global 2 }
|
||||
|
||||
deviceType OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..65534)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Device type"
|
||||
::= { global 3 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Measured values - Integer
|
||||
-----------------------------------------------------------------------
|
||||
tempInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature (value*10)"
|
||||
::= { valuesInt 1 }
|
||||
|
||||
humInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relative humidity (value*10)"
|
||||
::= { valuesInt 2 }
|
||||
|
||||
compValInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value (value*10)"
|
||||
::= { valuesInt 3 }
|
||||
|
||||
bin1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 1 state"
|
||||
::= { valuesInt 5 }
|
||||
|
||||
bin2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 2 state"
|
||||
::= { valuesInt 6 }
|
||||
|
||||
bin3Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 3 state"
|
||||
::= { valuesInt 7 }
|
||||
|
||||
re1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relay 1 state"
|
||||
::= { valuesInt 8 }
|
||||
|
||||
re2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Relay 2 state"
|
||||
::= { valuesInt 9 }
|
||||
|
||||
tempAlarm1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Temperature"
|
||||
::= { valuesInt 10 }
|
||||
|
||||
humAlarm1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Relative humidity"
|
||||
::= { valuesInt 11 }
|
||||
|
||||
compValAlarm1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm1 on Computed value"
|
||||
::= { valuesInt 12 }
|
||||
|
||||
tempAlarm2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Temperature"
|
||||
::= { valuesInt 14 }
|
||||
|
||||
humAlarm2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Relative humidity"
|
||||
::= { valuesInt 15 }
|
||||
|
||||
compValAlarm2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm2 on Computed value"
|
||||
::= { valuesInt 16 }
|
||||
|
||||
bin1AlarmInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 1"
|
||||
::= { valuesInt 18 }
|
||||
|
||||
bin2AlarmInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 2"
|
||||
::= { valuesInt 19 }
|
||||
|
||||
bin3AlarmInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..1)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Alarm on BIN Input 3"
|
||||
::= { valuesInt 20 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Alarm settings
|
||||
-----------------------------------------------------------------------
|
||||
tempLim1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm1 Limit (value*10)"
|
||||
::= { settings 1 }
|
||||
|
||||
humLim1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm1 Limit (value*10)"
|
||||
::= { settings 2 }
|
||||
|
||||
compValLim1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed Alarm1 Limit (value*10)"
|
||||
::= { settings 3 }
|
||||
|
||||
tempLim2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm2 Limit (value*10)"
|
||||
::= { settings 5 }
|
||||
|
||||
humLim2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm2 Limit (value*10)"
|
||||
::= { settings 6 }
|
||||
|
||||
compValLim2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm2 Limit (value*10)"
|
||||
::= { settings 7 }
|
||||
|
||||
tempHyst1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm1 Hysteresis (value*10)"
|
||||
::= { settings 9 }
|
||||
|
||||
humHyst1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm1 Hysteresis (value*10)"
|
||||
::= { settings 10 }
|
||||
|
||||
compValHyst1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm1 Hysteresis (value*10)"
|
||||
::= { settings 11 }
|
||||
|
||||
tempHyst2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm2 Hysteresis (value*10)"
|
||||
::= { settings 13 }
|
||||
|
||||
humHyst2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm2 Hysteresis (value*10)"
|
||||
::= { settings 14 }
|
||||
|
||||
compValHyst2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm2 Hysteresis (value*10)"
|
||||
::= { settings 15 }
|
||||
|
||||
tempDelay1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm1 Delay [sec]"
|
||||
::= { settings 17 }
|
||||
|
||||
humDelay1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm1 Delay [sec]"
|
||||
::= { settings 18 }
|
||||
|
||||
compValDelay1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm1 Delay [sec]"
|
||||
::= { settings 19 }
|
||||
|
||||
tempDelay2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm2 Delay [sec]"
|
||||
::= { settings 21 }
|
||||
|
||||
humDelay2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm2 Delay [sec]"
|
||||
::= { settings 22 }
|
||||
|
||||
compValDelay2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm2 Delay [sec]"
|
||||
::= { settings 23 }
|
||||
|
||||
tempType1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm1 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 25 }
|
||||
|
||||
humType1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm1 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 26 }
|
||||
|
||||
compValType1Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm1 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 27 }
|
||||
|
||||
tempType2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature Alarm2 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 29 }
|
||||
|
||||
humType2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity Alarm2 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 30 }
|
||||
|
||||
compValType2Int OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value Alarm2 Type; 0-disbaled, 1-low, 2-high"
|
||||
::= { settings 31 }
|
||||
|
||||
bin1DelayInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 1 Delay [sec]"
|
||||
::= { settings 33 }
|
||||
|
||||
bin2DelayInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 2 Delay [sec]"
|
||||
::= { settings 34 }
|
||||
|
||||
bin3DelayInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..30000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 3 Delay [sec]"
|
||||
::= { settings 35 }
|
||||
|
||||
bin1TypeInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 1 Type; 0-disbaled, 1-low state, 2-high state"
|
||||
::= { settings 36 }
|
||||
|
||||
bin2TypeInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 2 Type; 0-disbaled, 1-low state, 2-high state"
|
||||
::= { settings 37 }
|
||||
|
||||
bin3TypeInt OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "BIN Input 3 Type; 0-disbaled, 1-low state, 2-high state"
|
||||
::= { settings 38 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Trap message
|
||||
-----------------------------------------------------------------------
|
||||
messageString OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Message giving more detailed information on trap"
|
||||
::= { traps 1 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Tables
|
||||
-----------------------------------------------------------------------
|
||||
historyTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HistoryEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Table of the history values"
|
||||
::= { tables 1 }
|
||||
|
||||
historyEntry OBJECT-TYPE
|
||||
SYNTAX HistoryEntry
|
||||
ACCESS not-accessible
|
||||
STATUS optional
|
||||
DESCRIPTION "History values entries"
|
||||
INDEX { histTemp }
|
||||
::= { historyTable 1 }
|
||||
|
||||
HistoryEntry ::=
|
||||
SEQUENCE {
|
||||
histTemp
|
||||
INTEGER,
|
||||
histHum
|
||||
INTEGER,
|
||||
histCompVal
|
||||
INTEGER
|
||||
}
|
||||
|
||||
histTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER(-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Temperature reading"
|
||||
::= { historyEntry 1 }
|
||||
|
||||
histHum OBJECT-TYPE
|
||||
SYNTAX INTEGER(-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Humidity reading"
|
||||
::= { historyEntry 2 }
|
||||
|
||||
histCompVal OBJECT-TYPE
|
||||
SYNTAX INTEGER (-5000..20000)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Computed value reading"
|
||||
::= { historyEntry 3 }
|
||||
|
||||
|
||||
-----------------------------------------------------------------------
|
||||
-- Traps definition
|
||||
-----------------------------------------------------------------------
|
||||
|
||||
trapTest TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "Testing trap, testing trap by TSensor software"
|
||||
::= 0
|
||||
|
||||
trapNTPError TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "Error on time synchronisation via NTP"
|
||||
::= 1
|
||||
|
||||
trapEmailErrLogin TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SMTP error - unknown server"
|
||||
::= 2
|
||||
|
||||
trapEmailErrAuth TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SMTP error - authentication error"
|
||||
::= 3
|
||||
|
||||
trapEmailErrSome TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SMTP error - error during communication with server, unexpected return code"
|
||||
::= 4
|
||||
|
||||
trapEmailErrSocket TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SMTP error - socket error, server is not available"
|
||||
::= 5
|
||||
|
||||
trapEmailErrDNS TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SMTP error - DNS error"
|
||||
::= 6
|
||||
|
||||
trapSOAPErrFile TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SOAP error - file SOAP not found"
|
||||
::= 7
|
||||
|
||||
trapSOAPErrDNS TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SOAP error - DNS error"
|
||||
::= 8
|
||||
|
||||
trapSOAPErrSocket TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SOAP error - socket error, server is not available"
|
||||
::= 9
|
||||
|
||||
trapSOAPErrDelivery TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "SOAP error - delivery error, wrong return code from server"
|
||||
::= 10
|
||||
|
||||
trapTempAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, temp, tempAlarm1Int }
|
||||
DESCRIPTION "Trap for alarm1 on Temperature"
|
||||
::= 11
|
||||
|
||||
trapHumAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, hum, humAlarm1Int }
|
||||
DESCRIPTION "Trap for alarm1 on Relative humidity"
|
||||
::= 12
|
||||
|
||||
trapCompValAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, compVal, compValAlarm1Int }
|
||||
DESCRIPTION "Trap for alarm1 on Computed value"
|
||||
::= 13
|
||||
|
||||
trapTempAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, temp, tempAlarm2Int }
|
||||
DESCRIPTION "Trap for alarm2 on Temperature"
|
||||
::= 21
|
||||
|
||||
trapHumAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, hum, humAlarm2Int }
|
||||
DESCRIPTION "Trap for alarm2 on Relative humidity"
|
||||
::= 22
|
||||
|
||||
trapCompValAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, compVal, compValAlarm2Int }
|
||||
DESCRIPTION "Trap for alarm2 on Computed value"
|
||||
::= 23
|
||||
|
||||
trapTempClrAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, temp, tempAlarm1Int }
|
||||
DESCRIPTION "Trap for clearing alarm 1 on Temperature"
|
||||
::= 31
|
||||
|
||||
trapHumClrAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, hum, humAlarm1Int }
|
||||
DESCRIPTION "Trap for clearing alarm 1 on Relative humidity"
|
||||
::= 32
|
||||
|
||||
trapCompValClrAlarm1 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, compVal, compValAlarm1Int }
|
||||
DESCRIPTION "Trap for clearing alarm 1 on Computed value"
|
||||
::= 33
|
||||
|
||||
trapTempClrAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, temp, tempAlarm2Int }
|
||||
DESCRIPTION "Trap for clearing alarm 2 on Temperature"
|
||||
::= 41
|
||||
|
||||
trapHumClrAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, hum, humAlarm2Int }
|
||||
DESCRIPTION "Trap for clearing alarm 2 on Relative humidity"
|
||||
::= 42
|
||||
|
||||
trapCompValClrAlarm2 TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, compVal, compValAlarm2Int }
|
||||
DESCRIPTION "Trap for clearing alarm 2 on Computed value"
|
||||
::= 43
|
||||
|
||||
trapBin1Alarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin1Int, bin1AlarmInt }
|
||||
DESCRIPTION "Trap for alarm on BIN Input 1"
|
||||
::= 51
|
||||
|
||||
trapBin2Alarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin2Int, bin2AlarmInt }
|
||||
DESCRIPTION "Trap for alarm on BIN Input 2"
|
||||
::= 52
|
||||
|
||||
trapBin3Alarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin3Int, bin3AlarmInt }
|
||||
DESCRIPTION "Trap for alarm on BIN Input 3"
|
||||
::= 53
|
||||
|
||||
trapBin1ClrAlarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin1Int, bin1AlarmInt }
|
||||
DESCRIPTION "Trap for clearing alarm on BIN Input 1"
|
||||
::= 61
|
||||
|
||||
trapBin2ClrAlarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin2Int, bin2AlarmInt }
|
||||
DESCRIPTION "Trap for clearing alarm on BIN Input 2"
|
||||
::= 62
|
||||
|
||||
trapBin3ClrAlarm TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, bin3Int, bin3AlarmInt }
|
||||
DESCRIPTION "Trap for clearing alarm on BIN Input 3"
|
||||
::= 63
|
||||
|
||||
trapRelay1Closed TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, re1Int }
|
||||
DESCRIPTION "Trap for closed Relay 1"
|
||||
::= 70
|
||||
|
||||
trapRelay2Closed TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, re2Int }
|
||||
DESCRIPTION "Trap for closed Relay 2"
|
||||
::= 71
|
||||
|
||||
trapRelay1Open TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, re1Int }
|
||||
DESCRIPTION "Trap for open Relay 1"
|
||||
::= 72
|
||||
|
||||
trapRelay2Open TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString, re2Int }
|
||||
DESCRIPTION "Trap for open Relay 2"
|
||||
::= 73
|
||||
|
||||
trapAcousticActivated TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "Trap for activated acoustic"
|
||||
::= 74
|
||||
|
||||
trapAcousticDeactivated TRAP-TYPE
|
||||
ENTERPRISE comet
|
||||
VARIABLES { sensorName, messageString }
|
||||
DESCRIPTION "Trap for deactivated acoustic"
|
||||
::= 75
|
||||
|
||||
|
||||
END
|