FDRY-POE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32, Unsigned32 FROM SNMPv2-SMI -- [RFC2578]
|
||||
DisplayString FROM SNMPv2-TC -- [RFC2579]
|
||||
InterfaceIndex FROM IF-MIB
|
||||
snAgentSys FROM FOUNDRY-SN-ROOT-MIB
|
||||
;
|
||||
|
||||
snAgentPoe MODULE-IDENTITY
|
||||
LAST-UPDATED "201708070000Z" -- Aug 7, 2017
|
||||
ORGANIZATION "Ruckus Wireless, Inc.."
|
||||
CONTACT-INFO
|
||||
"Technical Support Center, Ruckus Wireless, Inc,
|
||||
350 West Java Drive,
|
||||
Sunnyvale, CA 94089, USA
|
||||
Support URL: https://support.ruckuswireless.com
|
||||
Phone: +1-855-782-5871"
|
||||
DESCRIPTION
|
||||
"The Ruckus Wireless proprietary MIB module for Power Over Ethernet(PoE)
|
||||
It has PoE port and module configuring information.
|
||||
|
||||
Copyright 1996-2017 Ruckus Wireless, Inc..
|
||||
All rights reserved.
|
||||
This Ruckus Wireless, Inc SNMP Management Information Base Specification
|
||||
embodies Ruckus Wireless, Inc confidential and proprietary
|
||||
intellectual property. Ruckus Wireless, Inc retains all
|
||||
title and ownership in the Specification, including any
|
||||
revisions.
|
||||
|
||||
This Specification is supplied AS IS, and Ruckus Wireless, Inc makes
|
||||
no warranty, either express or implied, as to the use,
|
||||
operation, condition, or performance of the Specification.
|
||||
"
|
||||
|
||||
REVISION "200909300000Z" -- September 30, 2009
|
||||
DESCRIPTION "Changed INTEGER to Integer32"
|
||||
REVISION "200904030000Z" -- 3 April 2009
|
||||
DESCRIPTION "Initial version, snAgentPoePortTable which was in SNMPv1 written in SNMPv2-SMI."
|
||||
REVISION "201708070000Z" -- Aug 7, 2017
|
||||
DESCRIPTION
|
||||
"Modified contact Info, Organization and Decscription"
|
||||
|
||||
::= { snAgentSys 14 }
|
||||
|
||||
-- Power Over Ethernet MIB Group
|
||||
|
||||
snAgentPoeGbl OBJECT IDENTIFIER ::= { snAgentPoe 1 }
|
||||
snAgentPoePort OBJECT IDENTIFIER ::= { snAgentPoe 2 }
|
||||
snAgentPoeModule OBJECT IDENTIFIER ::= { snAgentPoe 3 }
|
||||
snAgentPoeUnit OBJECT IDENTIFIER ::= { snAgentPoe 4 }
|
||||
|
||||
|
||||
-- Power Over Ethernet Global Objects
|
||||
|
||||
snAgentPoeGblPowerCapacityTotal OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows the total inline power capacity available in the device, measured in mWatts. "
|
||||
::= { snAgentPoeGbl 1 }
|
||||
|
||||
snAgentPoeGblPowerCapacityFree OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows the inline power capacity currently available in the device which is unallocated, measured in mWatts."
|
||||
::= { snAgentPoeGbl 2 }
|
||||
|
||||
snAgentPoeGblPowerAllocationsRequestsHonored OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows number of times the inline power allocations requests honored."
|
||||
::= { snAgentPoeGbl 3}
|
||||
|
||||
|
||||
-- Power Over Ethernet Port Table
|
||||
|
||||
snAgentPoePortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SnAgentPoePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of POE port information."
|
||||
::= { snAgentPoePort 2 }
|
||||
|
||||
snAgentPoePortEntry OBJECT-TYPE
|
||||
SYNTAX SnAgentPoePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the POE port table."
|
||||
INDEX { snAgentPoePortNumber }
|
||||
::= { snAgentPoePortTable 1 }
|
||||
|
||||
SnAgentPoePortEntry ::= SEQUENCE {
|
||||
snAgentPoePortNumber
|
||||
InterfaceIndex,
|
||||
snAgentPoePortControl
|
||||
INTEGER,
|
||||
snAgentPoePortWattage
|
||||
Integer32,
|
||||
snAgentPoePortClass
|
||||
Integer32,
|
||||
snAgentPoePortPriority
|
||||
INTEGER,
|
||||
snAgentPoePortConsumed
|
||||
Integer32,
|
||||
snAgentPoePortType
|
||||
DisplayString,
|
||||
snAgentPoePortPDClass
|
||||
Integer32,
|
||||
snAgentPoePortPDClassB
|
||||
Integer32
|
||||
}
|
||||
|
||||
snAgentPoePortNumber OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The port number in ifIndex value."
|
||||
::= { snAgentPoePortEntry 1 }
|
||||
|
||||
snAgentPoePortControl OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
disable(2),
|
||||
enable(3),
|
||||
enableLegacyDevice(4)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Control inline power on/off to a port. If a port does not
|
||||
have inline power capability, reading this object returns
|
||||
'other(1)'."
|
||||
::= { snAgentPoePortEntry 2 }
|
||||
|
||||
snAgentPoePortWattage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Adjust the inline power wattage. Valid value between 1000
|
||||
to 15400(IEEE802_3AF)/30000(IEEE802_3AT)/120000(IEEE802_3BT). Each unit is milliwatts. This object can only be
|
||||
set after snSwIfInLinePowerControl has been set to 'enable(3)'
|
||||
or 'enableLegacyDevice(4)'. If a port does not have inline
|
||||
power capability, reading this object returns undefined value."
|
||||
::= { snAgentPoePortEntry 3 }
|
||||
|
||||
snAgentPoePortClass OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Adjust the inline power class. Valid value between 0 to 3(IEEE802_3AF)/4(IEEE802_3AT).
|
||||
This object can only be set after snSwIfInLinePowerControl
|
||||
has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If
|
||||
a port does not have inline power capability or is not configured by
|
||||
the user, reading this object returns undefined value (0)."
|
||||
::= { snAgentPoePortEntry 4 }
|
||||
|
||||
snAgentPoePortPriority OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
invalid(0),
|
||||
critical(1),
|
||||
high(2),
|
||||
low(3),
|
||||
medium(4),
|
||||
other(5)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Inline power allocation priority for the power device
|
||||
0- Not a POE port, 1- Critical, 2- High, 3- Low,
|
||||
4- Medium, 5- other."
|
||||
::= { snAgentPoePortEntry 5 }
|
||||
|
||||
snAgentPoePortConsumed OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Inline power consumed by the port. Each unit is milliwatts."
|
||||
::= { snAgentPoePortEntry 6 }
|
||||
|
||||
snAgentPoePortType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Inline Power device type 802.3af, 802.3at, 802.3bt or Legacy device."
|
||||
::= { snAgentPoePortEntry 7 }
|
||||
|
||||
snAgentPoePortPDClass OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is a PD signature which the decive learns in the process of
|
||||
PD-classification. PD detection and PD-classification are two steps of powering PD.
|
||||
And if PD is powered without user power Spec, then PoE port power limit will be set
|
||||
based on pd-detected class. The value is PDClassA in case of dual signature (IEEE 802.3bt module) PD."
|
||||
::= { snAgentPoePortEntry 8 }
|
||||
|
||||
snAgentPoePortPDClassB OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is second PD class signature of dual signature PD which the device learns in the process of
|
||||
PD-classification. PD detection and PD-classification are two steps of powering PD.
|
||||
And if PD is powered without user power Spec, then PoE port power limit will be set
|
||||
based on both pd-detected classes. The value PDClassB is valid for dual signature PD (IEEE 802.3bt module)
|
||||
having PDClassA and PDClassB. If the PD is not dual signature the value is 0."
|
||||
::= { snAgentPoePortEntry 9 }
|
||||
|
||||
|
||||
-- Power Over Module Table
|
||||
|
||||
snAgentPoeModuleTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SnAgentPoeModuleEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of POE Module configuration."
|
||||
::= { snAgentPoeModule 1 }
|
||||
|
||||
snAgentPoeModuleEntry OBJECT-TYPE
|
||||
SYNTAX SnAgentPoeModuleEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the POE Module table."
|
||||
INDEX { snAgentPoeModuleNumber }
|
||||
::= { snAgentPoeModuleTable 1 }
|
||||
|
||||
SnAgentPoeModuleEntry ::= SEQUENCE {
|
||||
snAgentPoeModuleNumber
|
||||
Unsigned32,
|
||||
snAgentPoeModuleBudget
|
||||
Unsigned32,
|
||||
snAgentPoeModuleMaxPDTypeSupport
|
||||
INTEGER
|
||||
}
|
||||
|
||||
snAgentPoeModuleNumber OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This objects talks about POE module number."
|
||||
::= { snAgentPoeModuleEntry 1 }
|
||||
|
||||
snAgentPoeModuleBudget OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This objects talks about module power budget in watts."
|
||||
::= { snAgentPoeModuleEntry 2 }
|
||||
|
||||
snAgentPoeModuleMaxPDTypeSupport OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
ieee802dot3af(0),
|
||||
ieee802dot3at(1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object talks about the POE module type which is capable to support Power Device (PD) type
|
||||
ieee802.3af or ieee802.3at(also called POE plus)type. Module which support ieee802.3at can also
|
||||
support ieee802.3af but reverse is not true."
|
||||
|
||||
::= { snAgentPoeModuleEntry 3 }
|
||||
|
||||
|
||||
|
||||
-- Power Over Unit Table (stacking system)
|
||||
|
||||
snAgentPoeUnitTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SnAgentPoeUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of POE informaion for each unit. Only the unit
|
||||
that has POE capability appears in a table row"
|
||||
::= { snAgentPoeUnit 1 }
|
||||
|
||||
snAgentPoeUnitEntry OBJECT-TYPE
|
||||
SYNTAX SnAgentPoeUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the POE Unit table."
|
||||
INDEX { snAgentPoeUnitIndex }
|
||||
::= { snAgentPoeUnitTable 1 }
|
||||
|
||||
SnAgentPoeUnitEntry ::= SEQUENCE {
|
||||
snAgentPoeUnitIndex
|
||||
Unsigned32,
|
||||
snAgentPoeUnitPowerCapacityTotal
|
||||
Unsigned32,
|
||||
snAgentPoeUnitPowerCapacityFree
|
||||
Unsigned32,
|
||||
snAgentPoeUnitPowerAllocationsRequestsHonored
|
||||
Unsigned32
|
||||
}
|
||||
|
||||
snAgentPoeUnitIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Index to POE unit Table."
|
||||
::= { snAgentPoeUnitEntry 1 }
|
||||
|
||||
snAgentPoeUnitPowerCapacityTotal OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows the total inline power capacity available on that unit (device), measured in mWatts. "
|
||||
::= { snAgentPoeUnitEntry 2 }
|
||||
|
||||
snAgentPoeUnitPowerCapacityFree OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows the inline power capacity currently available on that unit (device) which is unallocated, measured in mWatts."
|
||||
::= { snAgentPoeUnitEntry 3 }
|
||||
|
||||
snAgentPoeUnitPowerAllocationsRequestsHonored OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object shows number of times the inline power allocations requests honored on that unit (device)."
|
||||
::= { snAgentPoeUnitEntry 4}
|
||||
|
||||
END
|