initial commit; version 22.5.12042
This commit is contained in:
847
mibs/broadcom/BRCM-BATTERY-MGMT-MIB
Normal file
847
mibs/broadcom/BRCM-BATTERY-MGMT-MIB
Normal file
@ -0,0 +1,847 @@
|
||||
--****************************************************************************
|
||||
--
|
||||
-- Copyright (c) 2005-2009 Broadcom Corporation
|
||||
--
|
||||
-- This program is the proprietary software of Broadcom Corporation and/or
|
||||
-- its licensors, and may only be used, duplicated, modified or distributed
|
||||
-- pursuant to the terms and conditions of a separate, written license
|
||||
-- agreement executed between you and Broadcom (an "Authorized License").
|
||||
-- Except as set forth in an Authorized License, Broadcom grants no license
|
||||
-- (express or implied), right to use, or waiver of any kind with respect to
|
||||
-- the Software, and Broadcom expressly reserves all rights in and to the
|
||||
-- Software and all intellectual property rights therein. IF YOU HAVE NO
|
||||
-- AUTHORIZED LICENSE, THEN YOU HAVE NO RIGHT TO USE THIS SOFTWARE IN ANY WAY,
|
||||
-- AND SHOULD IMMEDIATELY NOTIFY BROADCOM AND DISCONTINUE ALL USE OF THE
|
||||
-- SOFTWARE.
|
||||
--
|
||||
-- Except as expressly set forth in the Authorized License,
|
||||
--
|
||||
-- 1. This program, including its structure, sequence and organization,
|
||||
-- constitutes the valuable trade secrets of Broadcom, and you shall use all
|
||||
-- reasonable efforts to protect the confidentiality thereof, and to use this
|
||||
-- information only in connection with your use of Broadcom integrated circuit
|
||||
-- products.
|
||||
--
|
||||
-- 2. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE SOFTWARE IS PROVIDED
|
||||
-- "AS IS" AND WITH ALL FAULTS AND BROADCOM MAKES NO PROMISES, REPRESENTATIONS
|
||||
-- OR WARRANTIES, EITHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, WITH
|
||||
-- RESPECT TO THE SOFTWARE. BROADCOM SPECIFICALLY DISCLAIMS ANY AND ALL
|
||||
-- IMPLIED WARRANTIES OF TITLE, MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR
|
||||
-- A PARTICULAR PURPOSE, LACK OF VIRUSES, ACCURACY OR COMPLETENESS, QUIET
|
||||
-- ENJOYMENT, QUIET POSSESSION OR CORRESPONDENCE TO DESCRIPTION. YOU ASSUME
|
||||
-- THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE SOFTWARE.
|
||||
--
|
||||
-- 3. TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT SHALL BROADCOM
|
||||
-- OR ITS LICENSORS BE LIABLE FOR (i) CONSEQUENTIAL, INCIDENTAL, SPECIAL,
|
||||
-- INDIRECT, OR EXEMPLARY DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY
|
||||
-- RELATING TO YOUR USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF BROADCOM
|
||||
-- HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES; OR (ii) ANY AMOUNT IN
|
||||
-- EXCESS OF THE AMOUNT ACTUALLY PAID FOR THE SOFTWARE ITSELF OR U.S. $1,
|
||||
-- WHICHEVER IS GREATER. THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING ANY
|
||||
-- FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
|
||||
--
|
||||
--****************************************************************************
|
||||
-- Filename: brcm-battery-mgmt.mib
|
||||
-- Author: Kevin O'Neal
|
||||
-- Creation Date: February 11, 2005
|
||||
--
|
||||
--**************************************************************************
|
||||
-- Description:
|
||||
--
|
||||
-- private MIB for runtime (not factory) management of battery
|
||||
--
|
||||
--**************************************************************************
|
||||
-- Revision History:
|
||||
--
|
||||
--**************************************************************************
|
||||
|
||||
BRCM-BATTERY-MGMT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Integer32,
|
||||
Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
TruthValue,
|
||||
DateAndTime,
|
||||
DisplayString
|
||||
FROM SNMPv2-TC
|
||||
cableDataMgmtMIBObjects
|
||||
FROM BRCM-CABLEDATA-MGMT-MIB
|
||||
PositiveInteger
|
||||
FROM UPS-MIB;
|
||||
|
||||
batteryMgmt MODULE-IDENTITY
|
||||
LAST-UPDATED "200912140000Z"
|
||||
ORGANIZATION "Broadcom Corporation"
|
||||
CONTACT-INFO
|
||||
" BANANA-CABLEDATA
|
||||
(cableData branch of the
|
||||
Broadcom Assigned Numbers and Naming Authority)
|
||||
Broadcom Corporation
|
||||
|
||||
Postal: 4385 River Green Parkway
|
||||
Duluth, GA 30096
|
||||
USA
|
||||
|
||||
Tel: +1 770 232-0018
|
||||
|
||||
E-mail: banana-cabledata@broadcom.com"
|
||||
DESCRIPTION
|
||||
"Broadcom proprietary MIB for runtime management of objects related
|
||||
to battery powered devices."
|
||||
REVISION "200912140000Z"
|
||||
DESCRIPTION
|
||||
"Added new alarm bcmAlarmLowPower"
|
||||
REVISION "200903050000Z"
|
||||
DESCRIPTION
|
||||
"Corrected return values from battChargerLifeTestStatus and added notes
|
||||
to battNextLifeTest"
|
||||
REVISION "200810100000Z"
|
||||
DESCRIPTION
|
||||
"Added objects to facilitate automated testing of periodic life cycle test."
|
||||
REVISION "200807100000Z"
|
||||
DESCRIPTION
|
||||
"Added objects for control of periodic life testing and hardware faults."
|
||||
REVISION "200806180000Z"
|
||||
DESCRIPTION
|
||||
"Added group batteryThermalMgmt."
|
||||
REVISION "200803210000Z"
|
||||
DESCRIPTION
|
||||
"Changed max-access of battChargerMaximumCharge to read-only."
|
||||
REVISION "200709260000Z"
|
||||
DESCRIPTION
|
||||
"Added object battTemperature to the batteryTable."
|
||||
REVISION "200702050000Z"
|
||||
DESCRIPTION
|
||||
"Module description was updated.
|
||||
Compilability issues were cleaned up:
|
||||
- Chronological order of revision history was corrected.
|
||||
- Range restriction was added to object battIndex."
|
||||
REVISION "200612080000Z"
|
||||
DESCRIPTION
|
||||
"Added alarm bcmAlarmTempBadDischargeInhibited.
|
||||
Changed names of bcmAlarmBadTempChargeSuspended and
|
||||
bcmAlarmBadTempPowerReduced to bcmAlarmTempBadChargeSuspended
|
||||
and bcmAlarmTempBadPowerReduced for naming consistency with
|
||||
upsAlarmTempBad from the UPS-MIB."
|
||||
REVISION "200606200000Z"
|
||||
DESCRIPTION
|
||||
"Added objects related to per-pack EEPROM data to the batteryTable."
|
||||
REVISION "200602080000Z"
|
||||
DESCRIPTION
|
||||
"Added object battErrors to the batteryTable."
|
||||
REVISION "200602070100Z"
|
||||
DESCRIPTION
|
||||
"Added objects battEstimatedMinutesRemaining and
|
||||
battEstimatedChargeRemaining to the batteryTable."
|
||||
REVISION "200602070000Z"
|
||||
DESCRIPTION
|
||||
"Added alarms bcmAlarmBadTempChargeSuspended and
|
||||
bcmAlarmBadTempPowerReduced."
|
||||
REVISION "200512010000Z"
|
||||
DESCRIPTION
|
||||
"Added group batteryBcmAlarms and object
|
||||
battChargerLowChargeThreshold."
|
||||
REVISION "200508230000Z"
|
||||
DESCRIPTION
|
||||
"Added group batteryPowerMgmt."
|
||||
REVISION "200504190000Z"
|
||||
DESCRIPTION
|
||||
"Added object battChargerReplaceBatteryThreshold."
|
||||
REVISION "200502110000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { cableDataMgmtMIBObjects 10 }
|
||||
|
||||
HardwareFault ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This data type represents a bit-mask of potential hardware fault
|
||||
conditions in the battChargerHardwareFaultsAllowed and
|
||||
battChargerHardwareFaultsDetected entries."
|
||||
SYNTAX BITS {
|
||||
chargerOverVoltageFault(0),
|
||||
chargerOverCurrentFault(1),
|
||||
chargerPrequalVoltageFault(3),
|
||||
chargerDischargeOverCurrentFault(4),
|
||||
chargerGeneralDischargeFault(5),
|
||||
chargerInputOverVoltageFault(8),
|
||||
chargerUnexpectedBatteryVoltage(9),
|
||||
chargerUnexpectedBatteryCurrent(10),
|
||||
chargerBatteryOverVoltage(11),
|
||||
chargerBatteryEnablesShorted(12)
|
||||
}
|
||||
|
||||
batteryMgmtBase OBJECT IDENTIFIER ::= { batteryMgmt 1 }
|
||||
|
||||
batteryTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BatteryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of batteries present on the system."
|
||||
::= { batteryMgmtBase 1 }
|
||||
|
||||
batteryEntry OBJECT-TYPE
|
||||
SYNTAX BatteryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry describing the characteristics of an individual battery."
|
||||
INDEX { battIndex }
|
||||
::= { batteryTable 1 }
|
||||
|
||||
BatteryEntry ::=
|
||||
SEQUENCE {
|
||||
battIndex Integer32,
|
||||
battCapacity Unsigned32,
|
||||
battMaximumVoltage Unsigned32,
|
||||
battMinimumVoltage Unsigned32,
|
||||
battMeasuredVoltage Unsigned32,
|
||||
battIsValid TruthValue,
|
||||
battIsSelected TruthValue,
|
||||
battEstimatedMinutesRemaining PositiveInteger,
|
||||
battEstimatedChargeRemaining INTEGER,
|
||||
battErrors Unsigned32,
|
||||
battEpromRevision DisplayString,
|
||||
battPackSupplier DisplayString,
|
||||
battModelNumber DisplayString,
|
||||
battSerialNumber DisplayString,
|
||||
battCellSupplier DisplayString,
|
||||
battCellCapacity DisplayString,
|
||||
battCellDateCode DisplayString,
|
||||
battPackDateCode DisplayString,
|
||||
battTemperature Integer32,
|
||||
battPackGUID DisplayString,
|
||||
battActualCapacity Unsigned32,
|
||||
battAge Unsigned32,
|
||||
battNextLifeTest DisplayString
|
||||
battDischargeTable OCTET STRING,
|
||||
battCompressedDischargeTable OCTET STRING,
|
||||
battInvalidateNonVolSlot INTEGER
|
||||
}
|
||||
|
||||
battIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..4)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the instance number of this individual battery."
|
||||
::= { batteryEntry 1 }
|
||||
|
||||
battCapacity OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "milliamp hours"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The charge capacity of this battery."
|
||||
::= { batteryEntry 2 }
|
||||
|
||||
battMaximumVoltage OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The voltage at which this battery is considered to be fully charged.
|
||||
Note that if battChargerMaximumCharge is set to less than 100%, the
|
||||
battery will never be charged to this voltage."
|
||||
::= { batteryEntry 3 }
|
||||
|
||||
battMinimumVoltage OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The voltage at which this battery is considered to be fully
|
||||
discharged."
|
||||
::= { batteryEntry 4 }
|
||||
|
||||
battMeasuredVoltage OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The most recently measured voltage of this battery."
|
||||
::= { batteryEntry 5 }
|
||||
|
||||
battIsValid OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether this battery is considered valid by the battery
|
||||
charger. A value of false(2) here indicates some kind of failure
|
||||
with this battery."
|
||||
::= { batteryEntry 6 }
|
||||
|
||||
battIsSelected OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether this battery is currently selected for charging or
|
||||
discharging."
|
||||
::= { batteryEntry 7 }
|
||||
|
||||
battEstimatedMinutesRemaining OBJECT-TYPE
|
||||
SYNTAX PositiveInteger
|
||||
UNITS "minutes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An estimate of the time to depletion of this battery's charge
|
||||
under the present load conditions if the utility power
|
||||
is off and remains off, or if it were to be lost and
|
||||
remain off."
|
||||
::= { batteryEntry 8 }
|
||||
|
||||
battEstimatedChargeRemaining OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..100)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An estimate of this battery's charge remaining expressed
|
||||
as a percent of full charge."
|
||||
::= { batteryEntry 9 }
|
||||
|
||||
battErrors OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the number of errors reported by the charger when trying
|
||||
to charge this battery. This object should always have a value of
|
||||
zero if all is well with the charger and the battery."
|
||||
::= { batteryEntry 10 }
|
||||
|
||||
battEpromRevision OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of the battery EPROM."
|
||||
::= { batteryEntry 11 }
|
||||
|
||||
battPackSupplier OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Pack Supplier"
|
||||
::= { batteryEntry 12 }
|
||||
|
||||
battModelNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Model Number."
|
||||
::= { batteryEntry 13 }
|
||||
|
||||
battSerialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Serial Number."
|
||||
::= { batteryEntry 14 }
|
||||
|
||||
battCellSupplier OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Cell Supplier."
|
||||
::= { batteryEntry 15 }
|
||||
|
||||
battCellCapacity OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Cell Capacity."
|
||||
::= { batteryEntry 16 }
|
||||
|
||||
battCellDateCode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Cell Date Code(mmddyy)."
|
||||
::= { batteryEntry 17 }
|
||||
|
||||
battPackDateCode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery Pack Date Code(mmddyy)."
|
||||
::= { batteryEntry 18 }
|
||||
|
||||
battTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "degrees Centigrade"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature as reported by this battery. If the battery pack does
|
||||
not support temperature measurement then this object will not be
|
||||
supported."
|
||||
::= { batteryEntry 19 }
|
||||
|
||||
battPackGUID OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The battery pack globally unique ID (0x<cc><iiiiiiii><ff>).
|
||||
Where <cc> is an 8-bit CRC, <iiiiiiii> is the 48-bit ID, and <ff> is
|
||||
the 8-bit family code. If the hardware does not support reading
|
||||
the GUID then this object will not be supported."
|
||||
::= { batteryEntry 20 }
|
||||
|
||||
battActualCapacity OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "milliamp hours"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current maximum charge capacity of this battery. If the hardware
|
||||
does not support periodic life testing, this will return the same
|
||||
value as battDesignCapacity"
|
||||
::= { batteryEntry 21 }
|
||||
|
||||
battAge OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..100)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the current age of the battery as a percentage of its design
|
||||
capacity. This value could be calculated by dividing battActualCapacity
|
||||
by battDesignCapacity (however, this value clips at 100%.)"
|
||||
::= { batteryEntry 22 }
|
||||
|
||||
battNextLifeTest OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns/specifies the date and time of the next life test (mmddyyyy hh:mm:ss)
|
||||
for the specified pack. If the charger does not support periodic life
|
||||
testing then this object will not be supported. Setting this object to
|
||||
a value that resolves to a date in the past triggers an immediate life test.
|
||||
Note than any character - not just a space character - may be used to
|
||||
separate the date and time portions when setting this value."
|
||||
::= { batteryEntry 23 }
|
||||
|
||||
battDischargeTable OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the full discharge table for the specified battery as a comma-delimited string"
|
||||
::= { batteryEntry 24 }
|
||||
|
||||
battCompressedDischargeTable OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the compressed discharge table from the specified battery"
|
||||
::= { batteryEntry 25 }
|
||||
|
||||
battInvalidateNonVolSlot OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..1)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Invalidates the specified non-vol slot"
|
||||
::= { batteryEntry 26 }
|
||||
|
||||
batteryCharger OBJECT IDENTIFIER ::= { batteryMgmt 2 }
|
||||
|
||||
battChargerMicrocodeVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The version of the battery charger microcode."
|
||||
::= { batteryCharger 1 }
|
||||
|
||||
battChargerMicrocodeBuildTime OBJECT-TYPE
|
||||
SYNTAX DateAndTime
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The build date and time of the battery charger microcode."
|
||||
::= { batteryCharger 2 }
|
||||
|
||||
battChargerInputVoltage OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The most recently measured input voltage to the battery charger.
|
||||
Typically, if operating on battery power, this value will approach
|
||||
zero. If operating on utility power, this value will approach the
|
||||
value of the power supplied to the device."
|
||||
::= { batteryCharger 3 }
|
||||
|
||||
battChargerState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
initializing(1),
|
||||
idle(2),
|
||||
sleep(3),
|
||||
chargeInit(4),
|
||||
preQualification(5),
|
||||
fastCharge(6),
|
||||
trickleCharge(7),
|
||||
topOff(8),
|
||||
discharge(9),
|
||||
forcedDischarge(10),
|
||||
eternalSleep(11)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current state of the battery charger. Note that all states may
|
||||
not be supported on all types of chargers."
|
||||
::= { batteryCharger 4 }
|
||||
|
||||
battChargerMaximumCharge OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..100)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Reports the level to which the charger will charge the batteries."
|
||||
::= { batteryCharger 5 }
|
||||
|
||||
battChargerReplaceBatteryThreshold OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..100)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the minimum charge percentage that the battery must be able
|
||||
to reach when charging. If a battery cannot be charged above this
|
||||
percentage, it will be considered bad and battIsValid will transition
|
||||
to false(2)."
|
||||
::= { batteryCharger 6 }
|
||||
|
||||
battChargerLowChargeThreshold OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..100)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the charge percentage at which the bcmAlarmLowBatteryCharge
|
||||
will be raised."
|
||||
DEFVAL { 25 }
|
||||
::= { batteryCharger 7 }
|
||||
|
||||
battChargerHardwareFaultsAllowed OBJECT-TYPE
|
||||
SYNTAX HardwareFault
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the hardware faults that are currently allowed to affect the
|
||||
battery subsystem. If the charger does not support hardware faults then
|
||||
this object will not be supported. See bcmAlarmHardwareFault for a description
|
||||
of appropriate usage. Default value is all faults enabled."
|
||||
::= { batteryCharger 8 }
|
||||
|
||||
battChargerHardwareFaultsDetected OBJECT-TYPE
|
||||
SYNTAX HardwareFault
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the hardware faults that are currently active in the battery
|
||||
subsystem. Writing any valoe to this entry caues ALL faults to be reset.
|
||||
See bcmAlarmHardwareFault for a description of appropriate usage. If the charger
|
||||
does not support hardware faults then this object will not be supported.
|
||||
Default value is zero (0)."
|
||||
::= { batteryCharger 9 }
|
||||
|
||||
battChargerLifeTestInterval OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..365)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of days between periodic life tests (default = 180).
|
||||
If the charger does not support periodic life testing then this object
|
||||
will not be supported."
|
||||
::= { batteryCharger 10 }
|
||||
|
||||
battChargerLifeTestEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies whether or not periodic life testing is enabled. If the charger
|
||||
does not support periodic life testing then this object will not be supported.
|
||||
Default value is FALSE."
|
||||
::= { batteryCharger 11 }
|
||||
|
||||
battChargerLifeTestTOD OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the time of day (hh:mm) using a 24-hour clock at which battery
|
||||
life testing will be scheduled. If the charger does not support periodic
|
||||
life testing then this object will not be supported. Default value is '22:00'."
|
||||
::= { batteryCharger 12 }
|
||||
|
||||
battChargerLifeTestStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
lTStateIdle(1),
|
||||
lTStateBegin(2),
|
||||
lTStatePTD(3),
|
||||
lTStateStartCharge(4),
|
||||
lTStateHWIMP(5),
|
||||
lTStateCharge(6),
|
||||
lTStateStartSWIMP(7),
|
||||
lTStateComplSWIMP(8),
|
||||
lTStateDischarge(9),
|
||||
lTStateComplete(10)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the current life test state"
|
||||
::= { batteryCharger 13 }
|
||||
|
||||
battChargerAbortLifeTest OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this to TRUE aborts an in-progress life test. Reads always return
|
||||
FALSE. No effect if a life test is not currently in progress. If the
|
||||
charger does not support periodic life testing then this object will not
|
||||
be supported."
|
||||
::= { batteryCharger 14 }
|
||||
|
||||
batteryPowerMgmt OBJECT IDENTIFIER ::= { batteryMgmt 3 }
|
||||
|
||||
batteryPowerMgmtInterfaces OBJECT IDENTIFIER ::= { batteryPowerMgmt 1 }
|
||||
|
||||
battPowerMgmtCmDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the DOCSIS CM interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 1 }
|
||||
|
||||
battPowerMgmtEthernetDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the ethernet interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 2 }
|
||||
|
||||
battPowerMgmtUsbDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the USB interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 3 }
|
||||
|
||||
battPowerMgmtWiFiDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the WiFi interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 4 }
|
||||
|
||||
battPowerMgmtBluetoothDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the bluetooth interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 5 }
|
||||
|
||||
battPowerMgmtHpnaDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..2147483647)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the number of seconds following transition to battery power
|
||||
before the HPNA interface will enter power management mode. If
|
||||
set to -1, the interface will never enter power management mode and
|
||||
will remain at full power until utility power is restored or battery
|
||||
charge is depleted."
|
||||
DEFVAL { 0 }
|
||||
::= { batteryPowerMgmtInterfaces 6 }
|
||||
|
||||
-- batteryBcmAlarms provides a node under which enterprise-specific alarm
|
||||
-- OIDs may be defined for use in the upsAlarmTable.
|
||||
|
||||
batteryBcmAlarms OBJECT IDENTIFIER ::= { batteryMgmt 4 }
|
||||
|
||||
bcmAlarmLowBatteryCharge OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of upsEstimatedChargeRemaining is less than or equal
|
||||
to the value of battChargerLowChargeThreshold."
|
||||
::= { batteryBcmAlarms 1 }
|
||||
|
||||
bcmAlarmTempBadChargeSuspended OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature of the device has exceeded operational limits
|
||||
for safe battery charging, and battery charging has been suspended."
|
||||
::= { batteryBcmAlarms 2 }
|
||||
|
||||
bcmAlarmTempBadPowerReduced OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature of the device has exceeded operational limits,
|
||||
and the device has been placed in low power mode in an to attempt
|
||||
to reduce heat production."
|
||||
::= { batteryBcmAlarms 3 }
|
||||
|
||||
bcmAlarmBatteryMissing OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"There are no batteries installed in the device and the device will
|
||||
not be capable of sustaining power in the event of utility power
|
||||
loss."
|
||||
::= { batteryBcmAlarms 4 }
|
||||
|
||||
bcmAlarmTempBadDischargeInhibited OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature of the device has exceeded operational limits
|
||||
for safe battery discharging, and battery discharging has been
|
||||
inhibited."
|
||||
::= { batteryBcmAlarms 5 }
|
||||
|
||||
bcmAlarmHardwareFault OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that a hardware fault that is enabled in battChargerHardwareFaultsAllowed
|
||||
has been detected in battChargerHardwareFaultsDetected (i.e. the logical AND
|
||||
of these two objects is non-zero)."
|
||||
::= { batteryBcmAlarms 6 }
|
||||
|
||||
bcmAlarmLowPower OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the system has been placed into low power mode in order
|
||||
to extend battery life."
|
||||
::= { batteryBcmAlarms 7 }
|
||||
|
||||
batteryThermalMgmt OBJECT IDENTIFIER ::= { batteryMgmt 5 }
|
||||
|
||||
batteryThermalSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BatteryThermalSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of thermal sensors present on the system."
|
||||
::= { batteryThermalMgmt 1 }
|
||||
|
||||
batteryThermalSensorEntry OBJECT-TYPE
|
||||
SYNTAX BatteryThermalSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry describing a single thermal sensor."
|
||||
INDEX { battThermalSensorType, battThermalSensorIndex }
|
||||
::= { batteryThermalSensorTable 1 }
|
||||
|
||||
BatteryThermalSensorEntry ::=
|
||||
SEQUENCE {
|
||||
battThermalSensorType INTEGER,
|
||||
battThermalSensorIndex Integer32,
|
||||
battThermalSensorDescription DisplayString,
|
||||
battThermalSensorTemperature Integer32
|
||||
}
|
||||
|
||||
battThermalSensorType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
batteryPackSensor(1),
|
||||
boardLevelTemperatureSensor(2),
|
||||
thermalShutdownControllerSensor(3)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the type of this thermal sensor."
|
||||
::= { batteryThermalSensorEntry 1 }
|
||||
|
||||
battThermalSensorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..8)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the instance number of this thermal sensor."
|
||||
::= { batteryThermalSensorEntry 2 }
|
||||
|
||||
battThermalSensorDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of this thermal sensor."
|
||||
::= { batteryThermalSensorEntry 3 }
|
||||
|
||||
battThermalSensorTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "degrees Centigrade"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature as reported by this thermal sensor."
|
||||
::= { batteryThermalSensorEntry 4 }
|
||||
|
||||
END
|