@ -0,0 +1,127 @@
|
||||
--****************************************************************************
|
||||
--
|
||||
-- Copyright (c) 2009 Broadcom Corporation
|
||||
--
|
||||
-- This program is the proprietary software of Broadcom Corporation and/or
|
||||
-- its licensors, and may only be used, duplicated, modified or distributed
|
||||
-- pursuant to the terms and conditions of a separate, written license
|
||||
-- agreement executed between you and Broadcom (an "Authorized License").
|
||||
-- Except as set forth in an Authorized License, Broadcom grants no license
|
||||
-- (express or implied), right to use, or waiver of any kind with respect to
|
||||
-- the Software, and Broadcom expressly reserves all rights in and to the
|
||||
-- Software and all intellectual property rights therein. IF YOU HAVE NO
|
||||
-- AUTHORIZED LICENSE, THEN YOU HAVE NO RIGHT TO USE THIS SOFTWARE IN ANY WAY,
|
||||
-- AND SHOULD IMMEDIATELY NOTIFY BROADCOM AND DISCONTINUE ALL USE OF THE
|
||||
-- SOFTWARE.
|
||||
--
|
||||
-- Except as expressly set forth in the Authorized License,
|
||||
--
|
||||
-- 1. This program, including its structure, sequence and organization,
|
||||
-- constitutes the valuable trade secrets of Broadcom, and you shall use all
|
||||
-- reasonable efforts to protect the confidentiality thereof, and to use this
|
||||
-- information only in connection with your use of Broadcom integrated circuit
|
||||
-- products.
|
||||
--
|
||||
-- 2. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE SOFTWARE IS PROVIDED
|
||||
-- "AS IS" AND WITH ALL FAULTS AND BROADCOM MAKES NO PROMISES, REPRESENTATIONS
|
||||
-- OR WARRANTIES, EITHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, WITH
|
||||
-- RESPECT TO THE SOFTWARE. BROADCOM SPECIFICALLY DISCLAIMS ANY AND ALL
|
||||
-- IMPLIED WARRANTIES OF TITLE, MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR
|
||||
-- A PARTICULAR PURPOSE, LACK OF VIRUSES, ACCURACY OR COMPLETENESS, QUIET
|
||||
-- ENJOYMENT, QUIET POSSESSION OR CORRESPONDENCE TO DESCRIPTION. YOU ASSUME
|
||||
-- THE ENTIRE RISK ARISING OUT OF USE OR PERFORMANCE OF THE SOFTWARE.
|
||||
--
|
||||
-- 3. TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT SHALL BROADCOM
|
||||
-- OR ITS LICENSORS BE LIABLE FOR (i) CONSEQUENTIAL, INCIDENTAL, SPECIAL,
|
||||
-- INDIRECT, OR EXEMPLARY DAMAGES WHATSOEVER ARISING OUT OF OR IN ANY WAY
|
||||
-- RELATING TO YOUR USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF BROADCOM
|
||||
-- HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES; OR (ii) ANY AMOUNT IN
|
||||
-- EXCESS OF THE AMOUNT ACTUALLY PAID FOR THE SOFTWARE ITSELF OR U.S. $1,
|
||||
-- WHICHEVER IS GREATER. THESE LIMITATIONS SHALL APPLY NOTWITHSTANDING ANY
|
||||
-- FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY.
|
||||
--
|
||||
--****************************************************************************
|
||||
-- Filename: brcm-battery-engineering.mib
|
||||
-- Author: Kevin O'Neal
|
||||
-- Creation Date: June 10, 2009
|
||||
--
|
||||
--**************************************************************************
|
||||
-- Description:
|
||||
--
|
||||
-- private MIB for engineering (not runtime) management of battery
|
||||
-- features and functions.
|
||||
--
|
||||
--**************************************************************************
|
||||
-- Revision History:
|
||||
--
|
||||
-- See module identity.
|
||||
--
|
||||
--**************************************************************************
|
||||
|
||||
BRCM-BATTERY-ENGINEERING-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-IDENTITY,
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
cableDataEngineering
|
||||
FROM BRCM-CABLEDATA-ENGINEERING-MIB
|
||||
PositiveInteger
|
||||
FROM UPS-MIB;
|
||||
|
||||
batteryEngineering MODULE-IDENTITY
|
||||
LAST-UPDATED "200906100000Z"
|
||||
ORGANIZATION "Broadcom Corporation"
|
||||
CONTACT-INFO
|
||||
" BANANA-CABLEDATA
|
||||
(cableData branch of the
|
||||
Broadcom Assigned Numbers and Naming Authority)
|
||||
Broadcom Corporation
|
||||
|
||||
Postal: 4385 River Green Parkway
|
||||
Duluth, GA 30096
|
||||
USA
|
||||
|
||||
Tel: +1 770 232-0018
|
||||
|
||||
E-mail: banana-cabledata@broadcom.com"
|
||||
DESCRIPTION
|
||||
"Broadcom proprietary MIB for engineering management of objects related
|
||||
to battery powered devices."
|
||||
REVISION "200906100000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { cableDataEngineering 10 }
|
||||
|
||||
batteryEngrBase OBJECT IDENTIFIER ::= { batteryEngineering 1 }
|
||||
|
||||
battSimulatePowerSource OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
utility(1),
|
||||
battery(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object can be used to simulate transitions to and from different
|
||||
power sources for the purpose of evaluating system response to such
|
||||
transitions. Setting the object to utility(1) will dispatch an event
|
||||
indicating transition to utility power. Setting the object to
|
||||
battery(2) will dispatch an event indicating transition to battery
|
||||
power. Setting the object to none(0) will dispatch an event indicating
|
||||
a transition to the actual current power source, thus returning the
|
||||
system state to its actual current condition.
|
||||
|
||||
Note that setting this object does not actually result in a power
|
||||
source change, only in the publishing of an event that the power source
|
||||
has changed. As a result, the object may be set to battery(2) even if
|
||||
no battery is installed, or utility(1) if the device is not currently
|
||||
attached to utility power.
|
||||
|
||||
Further note that setting this object does not affect battery charging,
|
||||
state reported by objects in the BRCM-BATTERY-MGMT-MIB or UPS-MIB, etc."
|
||||
::= { batteryEngrBase 1 }
|
||||
|
||||