initial commit; version 22.5.12042
This commit is contained in:
328
mibs/bintec/BIANCA-X8000-MIBSYS-MIB
Normal file
328
mibs/bintec/BIANCA-X8000-MIBSYS-MIB
Normal file
@ -0,0 +1,328 @@
|
||||
-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
|
||||
|
||||
|
||||
-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved
|
||||
-- $RCSfile: mibsysx8,v $
|
||||
-- $Revision: 1.8 $
|
||||
|
||||
BIANCA-X8000-MIBSYS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
Counter, enterprises
|
||||
FROM RFC1155-SMI
|
||||
|
||||
DisplayString
|
||||
FROM RFC1158-MIB
|
||||
|
||||
TRAP-TYPE
|
||||
FROM RFC-1215
|
||||
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212;
|
||||
|
||||
bintec OBJECT IDENTIFIER ::= { enterprises 272 }
|
||||
bibo OBJECT IDENTIFIER ::= { bintec 4 }
|
||||
sys OBJECT IDENTIFIER ::= { bibo 17 }
|
||||
x8 OBJECT IDENTIFIER ::= { sys 3 }
|
||||
sysX8Config OBJECT IDENTIFIER
|
||||
::= { x8 1 }
|
||||
|
||||
sysX8Traps OBJECT IDENTIFIER ::= { x8 2 }
|
||||
|
||||
-- System Status and Configuration
|
||||
|
||||
sysX8ConfigPowerSupply1State OBJECT-TYPE
|
||||
SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the state of the power supply."
|
||||
::= { sysX8Config 1 }
|
||||
|
||||
sysX8ConfigPowerSupply1Temp OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..250)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the actual power supply temperature
|
||||
in the unit Celsius."
|
||||
::= { sysX8Config 2 }
|
||||
|
||||
sysX8ConfigPowerSupply1TempAlarmThreshold OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..250)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"Power supply 1 temperature threshold."
|
||||
DEFVAL { 40 }
|
||||
::= { sysX8Config 3 }
|
||||
|
||||
sysX8ConfigPowerSupply1TempAlarmTrap OBJECT-TYPE
|
||||
SYNTAX INTEGER { normal(1), critical(2) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"If the power supply temperature raises above the threshold,
|
||||
a alarm trap is generated every 60 seconds."
|
||||
::= { sysX8Config 4 }
|
||||
|
||||
sysX8ConfigPowerSupply2State OBJECT-TYPE
|
||||
SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable show the the state of the power supply."
|
||||
::= { sysX8Config 5 }
|
||||
|
||||
sysX8ConfigPowerSupply2Temp OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..250)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the actual power supply temperature
|
||||
in the unit Celsius."
|
||||
::= { sysX8Config 6 }
|
||||
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..250)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"Power supply 2 temperature threshold."
|
||||
DEFVAL { 40 }
|
||||
::= { sysX8Config 7 }
|
||||
|
||||
sysX8ConfigPowerSupply2TempAlarmTrap OBJECT-TYPE
|
||||
SYNTAX INTEGER { normal(1), critical(2) }
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"If the power supply temperature raises above the threshold,
|
||||
a alarm trap is generated every 60 seconds."
|
||||
::= { sysX8Config 8 }
|
||||
|
||||
sysX8ConfigFanControl OBJECT-TYPE
|
||||
SYNTAX INTEGER { auto(1), high(2) }
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This variable defines automatic fan control.
|
||||
In mode 'auto' the fans are automatically adjusted
|
||||
depending on the current temperature.
|
||||
In mode 'high' all fans remain at maximum speed."
|
||||
DEFVAL { high }
|
||||
::= { sysX8Config 9 }
|
||||
|
||||
sysX8ConfigFanVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the firmware version of
|
||||
the fan unit."
|
||||
::= { sysX8Config 10 }
|
||||
|
||||
sysX8ConfigFan1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the current turning speed."
|
||||
::= { sysX8Config 11 }
|
||||
|
||||
sysX8ConfigFan2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the current turning speed."
|
||||
::= { sysX8Config 12 }
|
||||
|
||||
sysX8ConfigFan3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the current turning speed."
|
||||
::= { sysX8Config 13 }
|
||||
|
||||
sysX8ConfigFan4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
|
||||
DESCRIPTION
|
||||
"This variable shows the current turning speed."
|
||||
::= { sysX8Config 14 }
|
||||
|
||||
---
|
||||
--- System Status and Configuration Traps
|
||||
---
|
||||
|
||||
sysX8TrapPowerSupply1Missing TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmTrap
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 1
|
||||
has been removed"
|
||||
::= 1
|
||||
|
||||
sysX8TrapPowerSupply1PowerOff TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmTrap
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 1
|
||||
has no power-good signal (no power input)"
|
||||
::= 2
|
||||
|
||||
sysX8TrapPowerSupply1PowerFail TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmTrap
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 1
|
||||
has been in the failure (bad DC output)"
|
||||
::= 3
|
||||
|
||||
sysX8TrapPowerSupply1PowerGood TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmTrap
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 1
|
||||
is running (supplying power)"
|
||||
::= 4
|
||||
|
||||
sysX8TrapPowerSupply1TempCritical TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 1 temperature
|
||||
raises above the critical alarm-threshold"
|
||||
::= 5
|
||||
|
||||
sysX8TrapPowerSupply1TempOk TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply1State,
|
||||
sysX8ConfigPowerSupply1Temp,
|
||||
sysX8ConfigPowerSupply1TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "A normal power supply 1 temperature has been restored."
|
||||
::= 6
|
||||
|
||||
sysX8TrapPowerSupply2Missing TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 2
|
||||
has been removed"
|
||||
::= 7
|
||||
|
||||
sysX8TrapPowerSupply2PowerOff TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 2
|
||||
has no power-good signal (no power input)"
|
||||
::= 8
|
||||
|
||||
sysX8TrapPowerSupply2PowerFail TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 2
|
||||
has been in the failure (bad DC output)"
|
||||
::= 9
|
||||
|
||||
sysX8TrapPowerSupply2PowerGood TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 2
|
||||
is running (supplying power)"
|
||||
::= 10
|
||||
|
||||
sysX8TrapPowerSupply2TempCritical TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "This trap signifies that the power supply 2 temperature
|
||||
raises above the critical alarm-threshold"
|
||||
::= 11
|
||||
|
||||
sysX8TrapPowerSupply2TempOk TRAP-TYPE
|
||||
ENTERPRISE sysX8Traps
|
||||
VARIABLES {
|
||||
sysDescr,
|
||||
sysName,
|
||||
sysX8ConfigPowerSupply2State,
|
||||
sysX8ConfigPowerSupply2Temp,
|
||||
sysX8ConfigPowerSupply2TempAlarmThreshold
|
||||
}
|
||||
DESCRIPTION "A normal power supply 2 temperature has been restored."
|
||||
::= 12
|
||||
|
||||
END
|
Reference in New Issue
Block a user