initial commit; version 22.5.12042
This commit is contained in:
391
mibs/a3com/A3COM-SWITCHING-SYSTEMS-TOKEN-RING-MIB
Normal file
391
mibs/a3com/A3COM-SWITCHING-SYSTEMS-TOKEN-RING-MIB
Normal file
@ -0,0 +1,391 @@
|
||||
-- 3Com Switching Systems Management Information Base
|
||||
-- Version 1.0.0
|
||||
-- February 13, 1998
|
||||
|
||||
-- 3Com Corporation
|
||||
-- 80 Central Street
|
||||
-- Boxborough, MA 01719
|
||||
-- (508) 264-1400
|
||||
|
||||
----------------------------------------------------------------------------------------
|
||||
-- 04/27/99 - tmeiczin moved a3ComSysTokenRing into 3cSysTokenRing.mib file
|
||||
--
|
||||
----------------------------------------------------------------------------------------
|
||||
|
||||
A3COM-SWITCHING-SYSTEMS-TOKEN-RING-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
enterprises, Counter, IpAddress
|
||||
FROM RFC1155-SMI
|
||||
DisplayString
|
||||
FROM RFC1213-MIB
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212
|
||||
TRAP-TYPE
|
||||
FROM RFC-1215;
|
||||
|
||||
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
|
||||
switchingSystemsMibs OBJECT IDENTIFIER ::= { a3Com 29 }
|
||||
a3ComSwitchingSystemsMib OBJECT IDENTIFIER ::= { switchingSystemsMibs 4 }
|
||||
a3ComSysTokenRingPort OBJECT IDENTIFIER ::= { a3ComSwitchingSystemsMib 13 }
|
||||
|
||||
-- The Switching Systems MIB token ring port group. Implementation of
|
||||
-- this group is mandatory for agents which manage token ring port
|
||||
-- resources.
|
||||
|
||||
a3ComSysTokenRingPortCount OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The count of token ring ports managed by this agent."
|
||||
::= { a3ComSysTokenRingPort 1 }
|
||||
|
||||
|
||||
-- The Switching Systems MIB token ring port table.
|
||||
|
||||
a3ComSysTokenRingPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF A3ComSysTokenRingPortEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of token ring port entries. A single entry exists
|
||||
in this list for each token ring port managed by this agent."
|
||||
::= { a3ComSysTokenRingPort 2 }
|
||||
|
||||
a3ComSysTokenRingPortEntry OBJECT-TYPE
|
||||
SYNTAX A3ComSysTokenRingPortEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A token ring port entry contains information about a
|
||||
particular token ring port managed by this agent."
|
||||
INDEX { a3ComSysTokenRingPortIndex }
|
||||
::= { a3ComSysTokenRingPortTable 1 }
|
||||
|
||||
A3ComSysTokenRingPortEntry ::=
|
||||
SEQUENCE {
|
||||
a3ComSysTokenRingPortIndex INTEGER,
|
||||
a3ComSysTokenRingPortIfIndex INTEGER,
|
||||
a3ComSysTokenRingPortLabel DisplayString,
|
||||
a3ComSysTokenRingPortInsertStatus INTEGER,
|
||||
a3ComSysTokenRingPortType INTEGER,
|
||||
a3ComSysTokenRingPortMode INTEGER,
|
||||
a3ComSysTokenRingPortSpeed INTEGER,
|
||||
a3ComSysTokenRingPortLineErrors Counter,
|
||||
a3ComSysTokenRingPortBurstErrors Counter,
|
||||
a3ComSysTokenRingPortACErrors Counter,
|
||||
a3ComSysTokenRingPortAbortTransErrors Counter,
|
||||
a3ComSysTokenRingPortInternalErrors Counter,
|
||||
a3ComSysTokenRingPortLostFrameErrors Counter,
|
||||
a3ComSysTokenRingPortReceiveCongestionErrors Counter,
|
||||
a3ComSysTokenRingPortFrameCopiedErrors Counter,
|
||||
a3ComSysTokenRingPortTokenErrors Counter,
|
||||
a3ComSysTokenRingPortSoftErrors Counter,
|
||||
a3ComSysTokenRingPortHardErrors Counter,
|
||||
a3ComSysTokenRingPortTransmitBeacons Counter,
|
||||
a3ComSysTokenRingPortLobeWires Counter,
|
||||
a3ComSysTokenRingPortRemoves Counter,
|
||||
a3ComSysTokenRingPortSingles Counter,
|
||||
a3ComSysTokenRingPortFreqErrors Counter,
|
||||
a3ComSysTokenRingPortRingStatus INTEGER
|
||||
}
|
||||
|
||||
a3ComSysTokenRingPortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The index of the token ring port identified by this entry,
|
||||
relative to this agent."
|
||||
::= { a3ComSysTokenRingPortEntry 1 }
|
||||
|
||||
a3ComSysTokenRingPortIfIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The value of the MIB-II ifIndex corresponding to the
|
||||
token ring port identified by this entry."
|
||||
::= { a3ComSysTokenRingPortEntry 2 }
|
||||
|
||||
a3ComSysTokenRingPortLabel OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..31))
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"An ASCII text string describing the token ring port
|
||||
identified by this entry."
|
||||
::= { a3ComSysTokenRingPortEntry 3 }
|
||||
|
||||
a3ComSysTokenRingPortInsertStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
inserted(1),
|
||||
deinserted(2)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current value of the link status for the token ring port
|
||||
identified by this entry."
|
||||
::= { a3ComSysTokenRingPortEntry 4 }
|
||||
|
||||
a3ComSysTokenRingPortType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
rj45(1),
|
||||
other(2)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Specific port type description for the token ring port
|
||||
identified by this entry."
|
||||
::= { a3ComSysTokenRingPortEntry 5 }
|
||||
|
||||
a3ComSysTokenRingPortMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
station(1),
|
||||
lobe(2)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current mode of the port. The default mode (station) is
|
||||
used to connect a hub to the port. Lobe mode is used to direct
|
||||
connect a Token Ring station into the port. This selection
|
||||
can only be made on ports 1 and 2 of the module."
|
||||
::= { a3ComSysTokenRingPortEntry 6 }
|
||||
|
||||
a3ComSysTokenRingPortSpeed OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fourMegabit(1),
|
||||
sixteenMegabit(2),
|
||||
sixteenMegabitETR(3)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current speed of the port. The default speed is
|
||||
sixteenMegabit."
|
||||
::= { a3ComSysTokenRingPortEntry 7 }
|
||||
|
||||
a3ComSysTokenRingPortLineErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a frame
|
||||
or token is copied or repeated by a
|
||||
station, the E bit is zero in the frame
|
||||
or token and one of the following
|
||||
conditions exists: 1) there is a
|
||||
non-data bit (J or K bit) between the SD
|
||||
and the ED of the frame or token, or
|
||||
2) there is an FCS error in the frame."
|
||||
::= { a3ComSysTokenRingPortEntry 8 }
|
||||
|
||||
a3ComSysTokenRingPortBurstErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
detects the absence of transitions for five
|
||||
half-bit timers (burst-five error)."
|
||||
::= { a3ComSysTokenRingPortEntry 9 }
|
||||
|
||||
a3ComSysTokenRingPortACErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
receives an AMP or SMP frame in which A is
|
||||
equal to C is equal to 0, and then receives
|
||||
another SMP frame with A is equal to C is
|
||||
equal to 0 without first receiving an AMP
|
||||
frame. It denotes a station that cannot set
|
||||
the AC bits properly."
|
||||
::= { a3ComSysTokenRingPortEntry 10 }
|
||||
|
||||
a3ComSysTokenRingPortAbortTransErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
transmits an abort delimiter while
|
||||
transmitting."
|
||||
::= { a3ComSysTokenRingPortEntry 11 }
|
||||
|
||||
a3ComSysTokenRingPortInternalErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
recognizes an internal error."
|
||||
::= { a3ComSysTokenRingPortEntry 12 }
|
||||
|
||||
a3ComSysTokenRingPortLostFrameErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
is transmitting and its TRR timer expires.
|
||||
This condition denotes a condition where a
|
||||
transmitting station in strip mode does not
|
||||
receive the trailer of the frame before the
|
||||
TRR timer goes off."
|
||||
::= { a3ComSysTokenRingPortEntry 13 }
|
||||
|
||||
a3ComSysTokenRingPortReceiveCongestionErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
recognizes a frame addressed to its
|
||||
specific address, but has no available
|
||||
buffer space indicating that the station
|
||||
is congested."
|
||||
::= { a3ComSysTokenRingPortEntry 14 }
|
||||
|
||||
a3ComSysTokenRingPortFrameCopiedErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
recognizes a frame addressed to its
|
||||
specific address and detects that the FS
|
||||
field A bits are set to 1 indicating a
|
||||
possible line hit or duplicate address."
|
||||
::= { a3ComSysTokenRingPortEntry 15 }
|
||||
|
||||
a3ComSysTokenRingPortTokenErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This counter is incremented when a station
|
||||
acting as the active monitor recognizes an
|
||||
error condition that needs a token
|
||||
transmitted."
|
||||
::= { a3ComSysTokenRingPortEntry 16 }
|
||||
|
||||
a3ComSysTokenRingPortSoftErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of Soft Errors the interface
|
||||
has detected. It directly corresponds to
|
||||
the number of Report Error MAC frames
|
||||
that this interface has transmitted.
|
||||
Soft Errors are those which are
|
||||
recoverable by the MAC layer protocols."
|
||||
::= { a3ComSysTokenRingPortEntry 17 }
|
||||
|
||||
a3ComSysTokenRingPortHardErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times this interface has
|
||||
detected an immediately recoverable
|
||||
fatal error. It denotes the number of
|
||||
times this interface is either
|
||||
transmitting or receiving beacon MAC
|
||||
frames."
|
||||
::= { a3ComSysTokenRingPortEntry 18 }
|
||||
|
||||
a3ComSysTokenRingPortTransmitBeacons OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times this interface has
|
||||
transmitted a beacon frame."
|
||||
::= { a3ComSysTokenRingPortEntry 19 }
|
||||
|
||||
a3ComSysTokenRingPortLobeWires OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the interface has
|
||||
detected an open or short circuit in the
|
||||
lobe data path. The adapter will be closed
|
||||
when this condition occurs."
|
||||
::= { a3ComSysTokenRingPortEntry 20 }
|
||||
|
||||
a3ComSysTokenRingPortRemoves OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the interface has
|
||||
received a Remove Ring Station MAC frame
|
||||
request. When this frame is received
|
||||
the interface will enter the close state."
|
||||
::= { a3ComSysTokenRingPortEntry 21 }
|
||||
|
||||
a3ComSysTokenRingPortSingles OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the interface has
|
||||
sensed that it is the only station on the
|
||||
ring. This will happen if the interface
|
||||
is the first one up on a ring, or if
|
||||
there is a hardware problem."
|
||||
::= { a3ComSysTokenRingPortEntry 22 }
|
||||
|
||||
a3ComSysTokenRingPortFreqErrors OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The number of times the interface has
|
||||
detected that the frequency of the
|
||||
incoming signal differs from the expected
|
||||
frequency."
|
||||
::= { a3ComSysTokenRingPortEntry 23 }
|
||||
|
||||
a3ComSysTokenRingPortRingStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current interface status which can
|
||||
be used to diagnose fluctuating problems
|
||||
that can occur on token rings, after a
|
||||
station has successfully been added to
|
||||
the ring.
|
||||
Before an open is completed, this
|
||||
object has the value for the 'no status'
|
||||
condition. This object is useful for
|
||||
debugging problems when the station
|
||||
can not even enter the ring.
|
||||
The object's value is a sum of
|
||||
values, one for each currently applicable
|
||||
condition. The following values are
|
||||
defined for various conditions:
|
||||
0 = No Problems detected
|
||||
32 = Ring Recovery
|
||||
64 = Single Station
|
||||
256 = Remove Received
|
||||
512 = reserved
|
||||
1024 = Auto-Removal Error
|
||||
2048 = Lobe Wire Fault
|
||||
4096 = Transmit Beacon
|
||||
8192 = Soft Error
|
||||
16384 = Hard Error
|
||||
32768 = Signal Loss
|
||||
131072 = no status, open not completed."
|
||||
::= { a3ComSysTokenRingPortEntry 24 }
|
||||
|
||||
END
|
Reference in New Issue
Block a user