Commit version 24.12.13800
This commit is contained in:
2289
mibs/synaccess/SYNLINK-MIB
Normal file
2289
mibs/synaccess/SYNLINK-MIB
Normal file
File diff suppressed because it is too large
Load Diff
509
mibs/synaccess/SYNSYS-MIB
Normal file
509
mibs/synaccess/SYNSYS-MIB
Normal file
@ -0,0 +1,509 @@
|
||||
-- Structure of Management Information
|
||||
-- The following MIB OIDs are supported:
|
||||
-- SNMPv2-MIB::sysName.0
|
||||
-- SNMPv2-MIB::sysObjectID.0
|
||||
-- SNMPv2-MIB::sysUpTime.0
|
||||
-- SNMPv2-MIB::sysContact.0
|
||||
-- SNMPv2-MIB::sysDescr.0
|
||||
-- SNMPv2-MIB::sysLocation.0
|
||||
|
||||
-- IF-MIB::ifDescr
|
||||
-- IP-MIB::ipAdEntIfIndex
|
||||
-- IF-MIB::ifPhysAddress
|
||||
-- IP-MIB::ipAdEntAddr
|
||||
-- IP-MIB::ipAdEntNetMask
|
||||
|
||||
SYNSYS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, NOTIFICATION-TYPE,
|
||||
OBJECT-IDENTITY,
|
||||
OBJECT-TYPE, Integer32,
|
||||
enterprises, IpAddress
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
synSys MODULE-IDENTITY
|
||||
LAST-UPDATED "202003200000Z"
|
||||
ORGANIZATION "Synaccess Networks Inc"
|
||||
CONTACT-INFO
|
||||
"Synaccess Networks, Inc.
|
||||
BY Shawn H.
|
||||
Engineering Dept.
|
||||
Postal:
|
||||
14425 N 79th St Ste C
|
||||
scottsdale, AZ 85260
|
||||
USA"
|
||||
DESCRIPTION
|
||||
"Top-level infrastructure of PDU project enterprise MIB tree"
|
||||
|
||||
REVISION "202003200000Z"
|
||||
DESCRIPTION
|
||||
"V4 Revised AC current from Integer to floating 2.2f"
|
||||
|
||||
REVISION "201505100000Z"
|
||||
DESCRIPTION
|
||||
"Added Eneger (Power) OIDs. Changed AC Current Draw data type from Byte to DisplayStrings"
|
||||
|
||||
-- DESCRIPTION
|
||||
-- "Added AC Current and temperature objects."
|
||||
|
||||
-- REVISION "200408020000Z"
|
||||
-- "V3 Initial version of this MIB module. The Structure of Management
|
||||
-- Information for the synaccess Networks enterprise."
|
||||
-- "202003200000Z"
|
||||
|
||||
::= { synaccess 3}
|
||||
|
||||
synaccess OBJECT IDENTIFIER ::= { enterprises 21728}
|
||||
|
||||
|
||||
|
||||
-- System Tables
|
||||
|
||||
systemDescr OBJECT IDENTIFIER ::= { synSys 1 }
|
||||
--
|
||||
|
||||
|
||||
systemModel OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..12))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The model number of the system."
|
||||
::= { systemDescr 1 }
|
||||
|
||||
systemName OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system site name or location name. "
|
||||
::= { systemDescr 2 }
|
||||
|
||||
powerOutletNum OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..64)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of AC outlets are equipped on the system."
|
||||
::= { systemDescr 3 }
|
||||
|
||||
serialPortNum OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..64)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of user serial console ports are equipped
|
||||
on the system. This number does not include the
|
||||
system Master Serial Port."
|
||||
::= { systemDescr 4 }
|
||||
|
||||
systemUpTime OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"systemUpTime in seconds. Read only."
|
||||
::= { systemDescr 5 }
|
||||
|
||||
swVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware version for this device. Read only."
|
||||
::= { systemDescr 6 }
|
||||
|
||||
acCurrentSensorNumber OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..32)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of AC current sensors are equipped in the unit.
|
||||
Energy monitoring module's current sensors are not applicable for this object."
|
||||
::= { systemDescr 7 }
|
||||
|
||||
temperatureProbe OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..64)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of temperature probe ports are equipped
|
||||
on the system. Note: Sensor probes may or may
|
||||
not be plugged-in to the ports"
|
||||
::= { systemDescr 8 }
|
||||
|
||||
acMPIModNumber OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..32)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of MPI(Measured Per Inlet) energy monitoring modules are equipped in the unit.
|
||||
An energy monitoring module provides status for voltage, amp,
|
||||
wattage, KWH and so on."
|
||||
::= { systemDescr 9 }
|
||||
|
||||
|
||||
-- outlet tables
|
||||
outletOpTables OBJECT IDENTIFIER ::= { synSys 2 }
|
||||
--
|
||||
|
||||
outletTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF OutletEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table of outlet operation status."
|
||||
::= { outletOpTables 1 }
|
||||
|
||||
outletEntry OBJECT-TYPE
|
||||
SYNTAX OutletEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Row definition for the system description table."
|
||||
INDEX {outletIndex}
|
||||
::= { outletTable 1 }
|
||||
|
||||
OutletEntry::= SEQUENCE {
|
||||
outletIndex Integer32,
|
||||
--outletID Integer32,
|
||||
outletName DisplayString,
|
||||
outletStatus INTEGER,
|
||||
outletAction INTEGER,
|
||||
outletCurrentDraw DisplayString
|
||||
}
|
||||
|
||||
|
||||
|
||||
outletIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..15)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index for the outlet table."
|
||||
::= { outletEntry 1 }
|
||||
|
||||
outletName OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..10))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Outlet label. Read operation."
|
||||
::= { outletEntry 2 }
|
||||
|
||||
outletStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
on(1),
|
||||
off(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Outlet status. 1-On. 2-0ff."
|
||||
|
||||
::= { outletEntry 3 }
|
||||
|
||||
outletAction OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
on(1),
|
||||
off(2),
|
||||
reboot(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Turn on/off or reboot an outlet."
|
||||
::= { outletEntry 4 }
|
||||
|
||||
|
||||
outletCurrentDraw OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"TRMS AC current draw from an outlet in Amps. This obj is applicable to MPO-system with AC current sensor for each outlet.MPO-Measured Per Outlet."
|
||||
|
||||
::= { outletEntry 5 }
|
||||
|
||||
|
||||
------Environment Tables
|
||||
enviroTable OBJECT IDENTIFIER ::= { synSys 3 }
|
||||
------
|
||||
|
||||
currentAlarmThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..35)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum AC Current Draw value recorded, in unit of Amps."
|
||||
::= { enviroTable 1}
|
||||
|
||||
currentDrawStatus1 OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..7))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total AC current draw in amps for the first
|
||||
AC power bank sensor. This object is valid
|
||||
only if the current sensor module is installed.
|
||||
This object is applicable to MPI (Measured Per Inlet) system.
|
||||
AC power draw is monitored on each power cord or bank. "
|
||||
::= { enviroTable 2 }
|
||||
|
||||
currentDrawStatus2 OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..7))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total AC current draw in amps for the second AC
|
||||
power bank sensor. This object is valid only if
|
||||
the current sensor module is installed.
|
||||
This object is applicable to MPI (Measured Per Inlet) system.
|
||||
AC power draw is monitored on each power cord or bank. "
|
||||
::= { enviroTable 3 }
|
||||
|
||||
|
||||
|
||||
currentDrawMax1 OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..7))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Max. AC current being detected for the entire system or the first power bank if applicable, in unit of Amps."
|
||||
::= { enviroTable 4}
|
||||
|
||||
currentDrawMax2 OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..7))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Max. AC current being detected for the 2nd power bank if applicable, in unit of Amps."
|
||||
::= { enviroTable 5}
|
||||
|
||||
temperatureUpThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (-60..100)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Environment temperature upper threshold in C."
|
||||
::= { enviroTable 6}
|
||||
|
||||
temperatureLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (-60..100)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Environment temperature low threshold in C."
|
||||
::= { enviroTable 7}
|
||||
|
||||
|
||||
temperatureReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (-60..100)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature reading in C. If value is -65,
|
||||
the temperature sensor is not installed. "
|
||||
::= { enviroTable 8}
|
||||
|
||||
|
||||
|
||||
|
||||
trapSetting OBJECT IDENTIFIER ::= { synSys 4 }
|
||||
|
||||
trapEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER { yes(1), no(0)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Indicates if this trap entry is enabled or not."
|
||||
::= { trapSetting 1 }
|
||||
|
||||
|
||||
trapRcvIP OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines TRAP receiver IP address."
|
||||
::= { trapSetting 2 }
|
||||
|
||||
trapCommunity OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..7))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap community to be used by agent to send trap."
|
||||
::= { trapSetting 3 }
|
||||
|
||||
energyStatus OBJECT IDENTIFIER ::= { synSys 5 }
|
||||
|
||||
mpiCurrent OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"TRMS currente value measured at AC power inlet.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
|
||||
::= { energyStatus 1 }
|
||||
|
||||
mpiVolt OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"TRMS voltage value measured at AC power inlet.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
|
||||
::= { energyStatus 2 }
|
||||
|
||||
|
||||
mpiActivePower OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Active Power value.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
|
||||
::= { energyStatus 3 }
|
||||
|
||||
mpiApparentPower OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Apparent Power value.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
::= { energyStatus 4 }
|
||||
|
||||
mpiPowerFactor OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PF (Power Factor) value.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
|
||||
|
||||
::= { energyStatus 5 }
|
||||
|
||||
|
||||
mpiAcFrequency OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"AC Frequency value.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
::= { energyStatus 6 }
|
||||
|
||||
mpiAcKwh OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Energy KWH readout value.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
::= { energyStatus 7 }
|
||||
|
||||
mpiAcKwhStartEPOCH OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"EPOCH value when KWH metering was started.
|
||||
This obj is applicable to a MPI-system. MPI-Measured Per Inlet."
|
||||
::= { energyStatus 8 }
|
||||
|
||||
|
||||
-- TRAP Event-----
|
||||
trapEvent OBJECT IDENTIFIER ::= { synSys 100 }
|
||||
|
||||
event OBJECT IDENTIFIER ::= { trapEvent 0 }
|
||||
|
||||
outletStatusEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName,
|
||||
outletName,
|
||||
outletStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Outlet status change event. "
|
||||
::= { event 1 }
|
||||
|
||||
|
||||
outletGroupStatusEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName,
|
||||
outletStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Outlet Group status change event."
|
||||
::= { event 2 }
|
||||
|
||||
autoPingRebootEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName,
|
||||
outletName
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"AutoPing and Reboot event."
|
||||
::= { event 3 }
|
||||
|
||||
temperatureAlarmEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Environment temperature high or
|
||||
low threshold crossing alarm event."
|
||||
::= { event 4 }
|
||||
|
||||
temperatureControlledOutletEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName,
|
||||
outletName
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Environment temperature upper and lOWer
|
||||
SET POINTS triggered outlet(s) change event."
|
||||
::= { event 5 }
|
||||
|
||||
systemPowerUpEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System powers up event."
|
||||
::= { event 6 }
|
||||
|
||||
kwhOverLimitEvent NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
systemName,
|
||||
outletName,
|
||||
mpiAcKwh,
|
||||
mpiAcKwhStartEPOCH
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Energy usage over preset limit.
|
||||
Current KWH reading and KWH accumulation starting EPOCH time."
|
||||
::= { event 7 }
|
||||
|
||||
-- ***********
|
||||
END
|
||||
|
||||
|
||||
|
||||
|