Commit version 24.12.13800
This commit is contained in:
336
mibs/siemens/RUGGEDCOM-POE-MIB
Normal file
336
mibs/siemens/RUGGEDCOM-POE-MIB
Normal file
@ -0,0 +1,336 @@
|
||||
RUGGEDCOM-POE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
|
||||
TruthValue FROM SNMPv2-TC
|
||||
OBJECT-GROUP FROM SNMPv2-CONF
|
||||
ruggedcomMgmt, ruggedcomTraps FROM RUGGEDCOM-MIB;
|
||||
|
||||
rcPoe MODULE-IDENTITY
|
||||
LAST-UPDATED "202109071400Z" -- Sep 09, 14:00 EST 2012;
|
||||
ORGANIZATION "RuggedCom"
|
||||
CONTACT-INFO
|
||||
"Postal: RuggedCom Inc.
|
||||
300 Applewood Crescent
|
||||
Concord, Ontario,
|
||||
L4K 5C7 Canada
|
||||
Tel: 1-905-856-5288
|
||||
E-Mail: support@ruggedcom.com"
|
||||
DESCRIPTION
|
||||
"Expanded list of PoE port Powered status to explicitly
|
||||
identify the 2-pair and 4-pair power modes."
|
||||
|
||||
REVISION "202109071400Z" -- Sep 09, 14:00 EST 2012;
|
||||
DESCRIPTION
|
||||
"RuggedCom prorietary to control and monitor PoE ports."
|
||||
|
||||
REVISION "201206011700Z" -- Jun 01, 17:00 EST 2012;
|
||||
DESCRIPTION
|
||||
"Fixed errors in IMPORTS."
|
||||
|
||||
REVISION "201102201000Z" -- Feb 20, 10:00 EST 2011
|
||||
DESCRIPTION
|
||||
"Initial version of RuggedCom prorietary to control and
|
||||
monitor PoE ports."
|
||||
|
||||
::= { ruggedcomMgmt 7 }
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- rcPoe subtrees
|
||||
-- ---------------------------------------------------------- --
|
||||
rcPoeBase OBJECT IDENTIFIER ::= { rcPoe 1 }
|
||||
rcPoeTables OBJECT IDENTIFIER ::= { rcPoe 2 }
|
||||
rcPoeConformance OBJECT IDENTIFIER ::= { rcPoe 3 }
|
||||
-- rcPoeCompliances OBJECT IDENTIFIER ::= { rcPoeConformance 1 }
|
||||
rcPoeGroups OBJECT IDENTIFIER ::= { rcPoeConformance 2 }
|
||||
-- Notification/trap branch
|
||||
ruggedcomPoeTraps OBJECT IDENTIFIER ::= { ruggedcomTraps 12 }
|
||||
|
||||
-- ---------------------------------------------------------------------- --
|
||||
-- Base subtree
|
||||
-- ---------------------------------------------------------------------- --
|
||||
rcPoeCapacity OBJECT-TYPE
|
||||
SYNTAX Integer32(0..65535)
|
||||
UNITS "W"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum total output power that can be provided by PoE
|
||||
ports.
|
||||
|
||||
If the value of this object is set to '0', that means that
|
||||
capacity is 'unlimited'.
|
||||
|
||||
When total power consumption reaches this limit, low priority PoE
|
||||
ports will be shutdown."
|
||||
::= { rcPoeBase 1}
|
||||
|
||||
|
||||
rcPoeMinimumVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32(39..57)
|
||||
UNITS "V"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The minimum required voltage to be provided by PoE ports.
|
||||
|
||||
The minimum required voltage for PoE ports.
|
||||
When PoE voltage droppes below this threshold, low priority PoE ports
|
||||
will be shutdown."
|
||||
::= { rcPoeBase 2}
|
||||
|
||||
rcPoeReenableTime OBJECT-TYPE
|
||||
SYNTAX Unsigned32(10..4294967295)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time to wait to turn on low priority PoE ports again after
|
||||
they were shutdown due to overload condition."
|
||||
::= { rcPoeBase 3}
|
||||
|
||||
rcPoeConsumption OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current total power consumption by all PoE devices."
|
||||
::= { rcPoeBase 4}
|
||||
|
||||
rcPoeOverheatStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this object will be set to 'true(1) if PoE is overheated.
|
||||
|
||||
Whenever the value of this object changes from false(2) to true(1),
|
||||
the device will generate rcPoeOverheat notification."
|
||||
::= { rcPoeBase 5}
|
||||
|
||||
rcPoeOverloadStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this object will be set to 'true(1) if PoE is overloaded.
|
||||
|
||||
Whenever the value of this object changes from false(2) to true(1),
|
||||
the device will generate rcPoeOverload notification."
|
||||
::= { rcPoeBase 6 }
|
||||
|
||||
rcPoeUndervoltageStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this object will be set to 'true(1) if PoE is undervoltage.
|
||||
|
||||
Whenever the value of this object changes from false(2) to true(1),
|
||||
the device will generate rcPoeUndervoltage notification."
|
||||
::= { rcPoeBase 7 }
|
||||
|
||||
|
||||
|
||||
-- ---------------------------------------------------------------------- --
|
||||
-- Tables subtree
|
||||
-- ---------------------------------------------------------------------- --
|
||||
|
||||
rcPoePortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RcPoePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of port entries."
|
||||
::= { rcPoeTables 1 }
|
||||
|
||||
rcPoePortEntry OBJECT-TYPE
|
||||
SYNTAX RcPoePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status and configuration parameters for a port."
|
||||
INDEX {
|
||||
rcPoePortNumber
|
||||
}
|
||||
::= { rcPoePortTable 1 }
|
||||
|
||||
RcPoePortEntry ::= SEQUENCE {
|
||||
rcPoePort Integer32,
|
||||
rcPoePortAdmin TruthValue,
|
||||
rcPoePortPriority INTEGER,
|
||||
rcPoePortPowered INTEGER,
|
||||
rcPoePortClass Integer32,
|
||||
rcPoePortVoltage Integer32,
|
||||
rcPoePortCurrent Integer32
|
||||
}
|
||||
|
||||
rcPoePort OBJECT-TYPE
|
||||
SYNTAX Integer32(1..65535)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The PoE port for which this entry contains information.
|
||||
|
||||
The value is limitted by number of ports in the device."
|
||||
::= { rcPoePortEntry 1}
|
||||
|
||||
rcPoePortAdmin OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The PoE port for which this entry contains information.
|
||||
|
||||
The value is limitted by number of ports in the device."
|
||||
::= { rcPoePortEntry 2}
|
||||
|
||||
rcPoePortPriority OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
low(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The priority of the port.
|
||||
|
||||
Low priority ports will be shut down first if the power supply is
|
||||
overloaded."
|
||||
::= { rcPoePortEntry 3}
|
||||
|
||||
rcPoePortPowered OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn (1),
|
||||
powerOff (2),
|
||||
twoPairsOn (3),
|
||||
fourPairsOn (4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Whether or not power is currently supplied by the port."
|
||||
::= { rcPoePortEntry 4}
|
||||
|
||||
rcPoePortClass OBJECT-TYPE
|
||||
SYNTAX Integer32(0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE Class value that defines the power level."
|
||||
REFERENCE
|
||||
"IEEE 802.3af/IEEE 802.3at"
|
||||
::= { rcPoePortEntry 5}
|
||||
|
||||
rcPoePortVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32(0..65535)
|
||||
UNITS "V"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE Class value that defines the power level."
|
||||
REFERENCE
|
||||
"IEEE 802.3af/IEEE 802.3at"
|
||||
::= { rcPoePortEntry 6}
|
||||
|
||||
rcPoePortCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32(0..65535)
|
||||
UNITS "mA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE Class value that defines the power level."
|
||||
REFERENCE
|
||||
"IEEE 802.3af/IEEE 802.3at"
|
||||
::= { rcPoePortEntry 7}
|
||||
|
||||
|
||||
-- ---------------------------------------------------------------------- --
|
||||
-- Traps
|
||||
-- ---------------------------------------------------------------------- --
|
||||
rcPoeOverheat NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE overheated."
|
||||
::= { ruggedcomPoeTraps 1 }
|
||||
|
||||
rcPoeOverload NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE overloaded."
|
||||
::= { ruggedcomPoeTraps 2 }
|
||||
|
||||
rcPoeUndervoltage NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"PoE voltage low."
|
||||
::= { ruggedcomPoeTraps 3 }
|
||||
|
||||
|
||||
-- ---------------------------------------------------------------------- --
|
||||
-- Object Groups
|
||||
-- ---------------------------------------------------------------------- --
|
||||
rcBasePoeGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rcPoeCapacity,
|
||||
rcPoeMinimumVoltage,
|
||||
rcPoeReenableTime,
|
||||
rcPoeConsumption
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group of objects providing ability ability to control and view
|
||||
PoE system parameters."
|
||||
::= { rcPoeGroups 1 }
|
||||
|
||||
rcBasePoeStatusGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rcPoeOverheatStatus,
|
||||
rcPoeOverloadStatus,
|
||||
rcPoeUndervoltageStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group of objects providing ability ability to view status of
|
||||
PoE in the device."
|
||||
::= { rcPoeGroups 2 }
|
||||
|
||||
rcPoeTableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rcPoePort,
|
||||
rcPoePortAdmin,
|
||||
rcPoePortPowered,
|
||||
rcPoePortClass,
|
||||
rcPoePortVoltage,
|
||||
rcPoePortCurrent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group of object providing information about ."
|
||||
::= { rcPoeGroups 3 }
|
||||
|
||||
|
||||
rcPoeTablePriorityGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rcPoePortPriority
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group of object providing information about ."
|
||||
::= { rcPoeGroups 4 }
|
||||
|
||||
|
||||
rcPoeNotifyGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
rcPoeOverheat,
|
||||
rcPoeOverload,
|
||||
rcPoeUndervoltage
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group of objects that define trap."
|
||||
::= { rcPoeGroups 5 }
|
||||
|
||||
END
|