Commit version 24.12.13800
This commit is contained in:
@ -2,10 +2,10 @@ ND020-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32, enterprises
|
||||
Integer32, enterprises, Unsigned32
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
NDMeter MODULE-IDENTITY
|
||||
ndMeter MODULE-IDENTITY
|
||||
LAST-UPDATED "201104200000Z"
|
||||
ORGANIZATION "Northern Design (Electronics) Ltd."
|
||||
CONTACT-INFO
|
||||
@ -28,181 +28,181 @@ NDMeter MODULE-IDENTITY
|
||||
::= { enterprises 37778 } -- assigned by IANA
|
||||
|
||||
meterkWhH OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kWh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kWh High."
|
||||
::= { NDMeter 7680 }
|
||||
::= { ndMeter 7680 }
|
||||
|
||||
|
||||
meterkWhL OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kWh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kWh Low."
|
||||
::= { NDMeter 7681 }
|
||||
::= { ndMeter 7681 }
|
||||
|
||||
|
||||
meterkVAhH OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVAh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kVAh High."
|
||||
::= { NDMeter 7682 }
|
||||
::= { ndMeter 7682 }
|
||||
|
||||
|
||||
meterkVAhL OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVAh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kVAh Low."
|
||||
::= { NDMeter 7683 }
|
||||
::= { ndMeter 7683 }
|
||||
|
||||
|
||||
meterkvarhH OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kvarh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kvarh High."
|
||||
::= { NDMeter 7684 }
|
||||
::= { ndMeter 7684 }
|
||||
|
||||
|
||||
meterkvarhL OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kvarh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kvarh Low."
|
||||
::= { NDMeter 7685 }
|
||||
::= { ndMeter 7685 }
|
||||
|
||||
|
||||
meterEkWhH OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kvarh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Export kWh High."
|
||||
::= { NDMeter 7686 }
|
||||
::= { ndMeter 7686 }
|
||||
|
||||
|
||||
meterEkWhL OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kvarh"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Export kWh Low."
|
||||
::= { NDMeter 7687 }
|
||||
::= { ndMeter 7687 }
|
||||
|
||||
|
||||
meterP1Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 current scaled by Ki."
|
||||
::= { NDMeter 7688 }
|
||||
::= { ndMeter 7688 }
|
||||
|
||||
meterP2Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 current scaled by Ki."
|
||||
::= { NDMeter 7689 }
|
||||
::= { ndMeter 7689 }
|
||||
|
||||
meterP3Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 current scaled by Ki."
|
||||
::= { NDMeter 7690 }
|
||||
::= { ndMeter 7690 }
|
||||
|
||||
|
||||
meterP1Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 voltage scaled by Kvp."
|
||||
::= { NDMeter 7691 }
|
||||
::= { ndMeter 7691 }
|
||||
|
||||
|
||||
meterP2Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 voltage scaled by Kvp."
|
||||
::= { NDMeter 7692 }
|
||||
::= { ndMeter 7692 }
|
||||
|
||||
|
||||
meterP3Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 voltage scaled by Kvp."
|
||||
::= { NDMeter 7693 }
|
||||
::= { ndMeter 7693 }
|
||||
|
||||
|
||||
meterP1P2Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase1 Phase2 voltage scaled by Kvl."
|
||||
::= { NDMeter 7694 }
|
||||
::= { ndMeter 7694 }
|
||||
|
||||
|
||||
meterP2P3Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase2 Phase3 voltage scaled by Kvl."
|
||||
::= { NDMeter 7695 }
|
||||
::= { ndMeter 7695 }
|
||||
|
||||
|
||||
meterP3P1Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase3 Phase1 voltage scaled by Kvl."
|
||||
::= { NDMeter 7696 }
|
||||
::= { ndMeter 7696 }
|
||||
|
||||
|
||||
meterFreq OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Hz x 10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Frequency x 10."
|
||||
::= { NDMeter 7697 }
|
||||
::= { ndMeter 7697 }
|
||||
|
||||
|
||||
meterPh1PF OBJECT-TYPE
|
||||
@ -212,7 +212,7 @@ meterPh1PF OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase1 PF x 100."
|
||||
::= { NDMeter 7698 }
|
||||
::= { ndMeter 7698 }
|
||||
|
||||
|
||||
meterPh2PF OBJECT-TYPE
|
||||
@ -222,7 +222,7 @@ meterPh2PF OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase2 PF x 100."
|
||||
::= { NDMeter 7699 }
|
||||
::= { ndMeter 7699 }
|
||||
|
||||
|
||||
meterPh3PF OBJECT-TYPE
|
||||
@ -232,7 +232,7 @@ meterPh3PF OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase3 PF x 100."
|
||||
::= { NDMeter 7700 }
|
||||
::= { ndMeter 7700 }
|
||||
|
||||
|
||||
meterSysPh1PF OBJECT-TYPE
|
||||
@ -242,7 +242,7 @@ meterSysPh1PF OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System PF x 100."
|
||||
::= { NDMeter 7701 }
|
||||
::= { ndMeter 7701 }
|
||||
|
||||
meterP1kW OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
@ -251,7 +251,7 @@ meterP1kW OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 kW scaled by Kp."
|
||||
::= { NDMeter 7702 }
|
||||
::= { ndMeter 7702 }
|
||||
|
||||
|
||||
meterP2kW OBJECT-TYPE
|
||||
@ -261,7 +261,7 @@ meterP2kW OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 kW scaled by Kp."
|
||||
::= { NDMeter 7703 }
|
||||
::= { ndMeter 7703 }
|
||||
|
||||
|
||||
meterP3kW OBJECT-TYPE
|
||||
@ -271,7 +271,7 @@ meterP3kW OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 kW scaled by Kp."
|
||||
::= { NDMeter 7704 }
|
||||
::= { ndMeter 7704 }
|
||||
|
||||
|
||||
meterSyskW OBJECT-TYPE
|
||||
@ -281,47 +281,47 @@ meterSyskW OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System kW scaled by Kp."
|
||||
::= { NDMeter 7705 }
|
||||
::= { ndMeter 7705 }
|
||||
|
||||
|
||||
meterP1kVA OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 kVA scaled by Kp."
|
||||
::= { NDMeter 7706 }
|
||||
::= { ndMeter 7706 }
|
||||
|
||||
|
||||
meterP2kVA OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 kVA scaled by Kp."
|
||||
::= { NDMeter 7707 }
|
||||
::= { ndMeter 7707 }
|
||||
|
||||
|
||||
meterP3kVA OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 kVA scaled by Kp."
|
||||
::= { NDMeter 7708 }
|
||||
::= { ndMeter 7708 }
|
||||
|
||||
|
||||
meterSyskVA OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System kVA scaled by Kp."
|
||||
::= { NDMeter 7709 }
|
||||
::= { ndMeter 7709 }
|
||||
|
||||
meterP1kvar OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
@ -330,7 +330,7 @@ meterP1kvar OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 kvar scaled by Kp."
|
||||
::= { NDMeter 7710 }
|
||||
::= { ndMeter 7710 }
|
||||
|
||||
|
||||
meterP2kvar OBJECT-TYPE
|
||||
@ -340,7 +340,7 @@ meterP2kvar OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 kvar scaled by Kp."
|
||||
::= { NDMeter 7711 }
|
||||
::= { ndMeter 7711 }
|
||||
|
||||
|
||||
meterP3kvar OBJECT-TYPE
|
||||
@ -350,7 +350,7 @@ meterP3kvar OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 kvar scaled by Kp."
|
||||
::= { NDMeter 7712 }
|
||||
::= { ndMeter 7712 }
|
||||
|
||||
|
||||
meterSyskvar OBJECT-TYPE
|
||||
@ -360,123 +360,123 @@ meterSyskvar OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System kvar scaled by Kp."
|
||||
::= { NDMeter 7713 }
|
||||
::= { ndMeter 7713 }
|
||||
|
||||
|
||||
meterP1AmpsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 current demand scaled by Ki."
|
||||
::= { NDMeter 7714 }
|
||||
::= { ndMeter 7714 }
|
||||
|
||||
meterP2AmpsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 current demand scaled by Ki."
|
||||
::= { NDMeter 7715 }
|
||||
::= { ndMeter 7715 }
|
||||
|
||||
meterP3AmpsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 current demand scaled by Ki."
|
||||
::= { NDMeter 7716 }
|
||||
::= { ndMeter 7716 }
|
||||
|
||||
|
||||
meterP1VoltsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 1 voltage demand scaled by Kvp."
|
||||
::= { NDMeter 7717 }
|
||||
::= { ndMeter 7717 }
|
||||
|
||||
|
||||
meterP2VoltsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 2 voltage demand scaled by Kvp."
|
||||
::= { NDMeter 7718 }
|
||||
::= { ndMeter 7718 }
|
||||
|
||||
|
||||
meterP3VoltsDem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase 3 voltage demand scaled by Kvp."
|
||||
::= { NDMeter 7719 }
|
||||
::= { ndMeter 7719 }
|
||||
|
||||
|
||||
meterPkP1Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 1 current scaled by Ki."
|
||||
::= { NDMeter 7720 }
|
||||
::= { ndMeter 7720 }
|
||||
|
||||
meterPkP2Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 2 current scaled by Ki."
|
||||
::= { NDMeter 7721 }
|
||||
::= { ndMeter 7721 }
|
||||
|
||||
meterPkP3Amps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 3 current scaled by Ki."
|
||||
::= { NDMeter 7722 }
|
||||
::= { ndMeter 7722 }
|
||||
|
||||
|
||||
meterPkP1Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 1 voltage scaled by Kvp."
|
||||
::= { NDMeter 7723 }
|
||||
::= { ndMeter 7723 }
|
||||
|
||||
|
||||
meterPkP2Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 2 voltage scaled by Kvp."
|
||||
::= { NDMeter 7724 }
|
||||
::= { ndMeter 7724 }
|
||||
|
||||
|
||||
meterPkP3Volts OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Voltsx10"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak Phase 3 voltage scaled by Kvp."
|
||||
::= { NDMeter 7725 }
|
||||
::= { ndMeter 7725 }
|
||||
|
||||
|
||||
|
||||
@ -487,17 +487,17 @@ meterkWDem OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kW Demand scaled with Kp."
|
||||
::= { NDMeter 7726 }
|
||||
::= { ndMeter 7726 }
|
||||
|
||||
|
||||
meterkVADem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kVA Demand scaled with Kp."
|
||||
::= { NDMeter 7727 }
|
||||
::= { ndMeter 7727 }
|
||||
|
||||
|
||||
meterkvarDem OBJECT-TYPE
|
||||
@ -507,7 +507,7 @@ meterkvarDem OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"kvar Demand scaled with Kp."
|
||||
::= { NDMeter 7728 }
|
||||
::= { ndMeter 7728 }
|
||||
|
||||
|
||||
|
||||
@ -518,17 +518,17 @@ meterPkkWDem OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak kW Demand scaled with Kp."
|
||||
::= { NDMeter 7729 }
|
||||
::= { ndMeter 7729 }
|
||||
|
||||
|
||||
meterPkkVADem OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "kVA"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak kVA Demand scaled with Kp."
|
||||
::= { NDMeter 7730 }
|
||||
::= { ndMeter 7730 }
|
||||
|
||||
|
||||
meterPkkvarDem OBJECT-TYPE
|
||||
@ -538,67 +538,67 @@ meterPkkvarDem OBJECT-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Peak kvar Demand scaled with Kp."
|
||||
::= { NDMeter 7731 }
|
||||
::= { ndMeter 7731 }
|
||||
|
||||
|
||||
meterNeuAmps OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Neutral current x 10."
|
||||
::= { NDMeter 7732 }
|
||||
::= { ndMeter 7732 }
|
||||
|
||||
|
||||
meterAmpsScal OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Ki"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Amps scale."
|
||||
::= { NDMeter 7733 }
|
||||
::= { ndMeter 7733 }
|
||||
|
||||
|
||||
meterPhVoltScal OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Kvp"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phase Volts scale."
|
||||
::= { NDMeter 7734 }
|
||||
::= { ndMeter 7734 }
|
||||
|
||||
|
||||
meterLLVoltScal OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Kvl"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Line Volts scale."
|
||||
::= { NDMeter 7735 }
|
||||
::= { ndMeter 7735 }
|
||||
|
||||
|
||||
meterPowerScal OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Kp"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Power scale."
|
||||
::= { NDMeter 7736 }
|
||||
::= { ndMeter 7736 }
|
||||
|
||||
|
||||
meterEnergyScal OBJECT-TYPE
|
||||
SYNTAX UInteger32
|
||||
SYNTAX Unsigned32
|
||||
UNITS "Ke"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Energy scale."
|
||||
::= { NDMeter 7737 }
|
||||
::= { ndMeter 7737 }
|
||||
|
||||
|
||||
END
|
||||
|
Reference in New Issue
Block a user