Commit version 24.12.13800

This commit is contained in:
2025-01-06 17:35:06 -05:00
parent b7f6a79c2c
commit 55d9218816
6133 changed files with 4239740 additions and 1374287 deletions

View File

@ -1,6 +1,6 @@
TROPIC-SYNCE-MIB DEFINITIONS ::= BEGIN
-- (c) Copyright 2019 Nokia Networks. All rights reserved.
-- (c) Copyright 2021 Nokia Networks. All rights reserved.
-- This software is the confidential and proprietary property of
-- Nokia and may only be used in accordance with the terms of the
-- license agreement provided with this software.
@ -13,15 +13,17 @@ IMPORTS
ifIndex,
InterfaceIndexOrZero FROM IF-MIB
TropicStateQualifierType,
TropicOperationalCapabilityType FROM TROPIC-TC
TropicOperationalCapabilityType,
NokiaSyncStatusMsgType FROM TROPIC-TC
tnShelfIndex FROM TROPIC-SHELF-MIB
tnSlotIndex FROM TROPIC-SLOT-MIB
tnPortModules, tnSyncEMIB FROM TROPIC-GLOBAL-REG
tnSysSwitchId FROM TROPIC-SYSTEM-MIB
AluWdmPtpClockIdentifier FROM TROPIC-PTP-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
tnSyncEMibModule MODULE-IDENTITY
LAST-UPDATED "201809071200Z"
LAST-UPDATED "202011201200Z"
ORGANIZATION "Nokia"
CONTACT-INFO "Nokia
Attn: Jeff Donnelly
@ -33,6 +35,58 @@ IMPORTS
DESCRIPTION "Synchronous Ethernet MIB attributes."
REVISION "202011201200Z"
DESCRIPTION "1) Added the following to tnSyncELineRefTable:
tnSyncELineRefProvQLOfStationClock
tnSyncELineRefIncSSMMsgOfStationClock
tnSyncELineRefIncSSMStatusOfStationClock.
2) Added the following to tnWanSyncEOutgoingForceSsmTrans:
ePRTC(23)
to
eSEC(26).
3) Updated DESCRIPTION of the following:
tnWanSyncEOutgoingForceSsmTrans."
REVISION "202011131200Z"
DESCRIPTION "1) Updated DESCRIPTION of the following:
tnSyncESystemQL
tnSyncEStationClockSystemQL
tnSyncEStationClockSyncMsg
tnSyncESyncMsg.
2) Changed SYNTAX of the following from TruthValue to NokiaSyncStatusMsgType:
tnSyncESyncMsg
tnSyncEStationClockSyncMsg."
REVISION "202011061200Z"
DESCRIPTION "1) Updated DESCRIPTION of the following:
tnSyncEQLDegradeThreshold
tnSyncEStationClockQLThreshold
tnSyncELineRefProvQL
tnSyncELineRefIncSSMMsg
tnSyncEOutgoingForceSsmTrans.
2) Added the following to tnSyncELineRefTable:
tnSyncELineRefIncExtdQLTLVClockID
tnSyncELineRefIncExtdQLTLVMixedClockType
tnSyncELineRefIncExtdQLTLVPartialChain
tnSyncELineRefIncExtdQLTLVNumeEEC
tnSyncELineRefIncExtdQLTLVNumEEC.
3) Added the following to tnSyncEOutgoingForceSsmTrans:
ePRTC(23)
to
eSEC(26)."
REVISION "202001101200Z"
DESCRIPTION "Added the following to tnSyncEBITSPortTable:
tnSyncEBITSPortAlmProfName."
REVISION "201909061200Z"
DESCRIPTION "1) Added the following to tnSyncETable:
tnSyncEAlmProfName.
2) Added the following to tnSyncELineRefTable:
tnSyncELineRefAlmProfName.
3) Added the following to tnSyncEStationClockTable:
tnSyncEStationClockAlmProfName."
REVISION "201809071200Z"
DESCRIPTION "Added the following to tnWanTable:
tnWanDescription."
@ -248,23 +302,24 @@ IMPORTS
TnSyncEntry ::=
SEQUENCE {
tnSyncESyncMsg TruthValue,
tnSyncEActiveRef INTEGER,
tnSyncEWTR Unsigned32,
tnSyncESwCmdLineRef Unsigned32,
tnSyncEClkModState INTEGER,
tnSyncESystemQL Integer32,
tnSyncEQLDegradeThreshold Integer32,
tnSyncECurrentActiveLineRefFreqOff Integer32
tnSyncESyncMsg NokiaSyncStatusMsgType,
tnSyncEActiveRef INTEGER,
tnSyncEWTR Unsigned32,
tnSyncESwCmdLineRef Unsigned32,
tnSyncEClkModState INTEGER,
tnSyncESystemQL Integer32,
tnSyncEQLDegradeThreshold Integer32,
tnSyncECurrentActiveLineRefFreqOff Integer32,
tnSyncEAlmProfName OCTET STRING
}
tnSyncESyncMsg OBJECT-TYPE
SYNTAX TruthValue
SYNTAX NokiaSyncStatusMsgType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Determines if the timing reference selection for
system timing uses sync status messaging (SSM
Qualities)."
DESCRIPTION "Determines if the timing reference selection for system
timing uses Synchronization Status Message (SSM) Quality
Levels or Enhanced Quality Levels."
DEFVAL { false }
::= { tnSyncEEntry 1 }
@ -300,22 +355,22 @@ IMPORTS
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The third byte represents the switch command:
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
The last byte represents the line reference switch to:
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5."
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5."
::= { tnSyncEEntry 4 }
tnSyncEClkModState OBJECT-TYPE
@ -340,12 +395,16 @@ IMPORTS
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
@ -357,7 +416,10 @@ IMPORTS
17 - SMC
18 - ST4
19 - DUS
20 - PNO."
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEEntry 6 }
tnSyncEQLDegradeThreshold OBJECT-TYPE
@ -368,10 +430,14 @@ IMPORTS
for systme timing reference.
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC - Default.
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC - Default
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
@ -379,8 +445,10 @@ IMPORTS
13 - ST2
14 - TNC
15 - ST3E
16 - ST3 - Default."
16 - ST3 - Default
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEEntry 7 }
tnSyncECurrentActiveLineRefFreqOff OBJECT-TYPE
@ -391,6 +459,13 @@ IMPORTS
DESCRIPTION "The current frequency offset of the active timing reference."
::= { tnSyncEEntry 8 }
tnSyncEAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncEEntry 9 }
-------------------------------------------------------------------------------
-- Synchronous Ethernet Timing Line Reference Map Table
--------------------------------------------------------------------------------
@ -413,23 +488,32 @@ IMPORTS
TnSyncELineRefEntry ::=
SEQUENCE {
tnSyncELineRefIndex Unsigned32,
tnSyncELineRefAssignedPort INTEGER,
tnSyncELineRefPriority Unsigned32,
tnSyncELineRefAdminState INTEGER,
tnSyncELineRefOperState INTEGER,
tnSyncELineLockOut TruthValue,
tnSyncELineRefState INTEGER,
tnSyncELineRefSwState INTEGER,
tnSyncELineRefIncSSMMsg Integer32,
tnSyncELineRefIncSSMStatus Integer32,
tnSyncELineRefIncSSMSupp INTEGER,
tnSyncELineRefProvQL Integer32,
tnSyncELineRefAssociatedPort InterfaceIndexOrZero,
tnSyncELineRefPriorityOfStationClock Unsigned32,
tnSyncELineRefLockOutOfStationClock TruthValue,
tnSyncELineRefSwStateOfStationClock INTEGER,
tnSyncELineRefCurrentFreqOff Integer32
tnSyncELineRefIndex Unsigned32,
tnSyncELineRefAssignedPort INTEGER,
tnSyncELineRefPriority Unsigned32,
tnSyncELineRefAdminState INTEGER,
tnSyncELineRefOperState INTEGER,
tnSyncELineLockOut TruthValue,
tnSyncELineRefState INTEGER,
tnSyncELineRefSwState INTEGER,
tnSyncELineRefIncSSMMsg Integer32,
tnSyncELineRefIncSSMStatus Integer32,
tnSyncELineRefIncSSMSupp INTEGER,
tnSyncELineRefProvQL Integer32,
tnSyncELineRefAssociatedPort InterfaceIndexOrZero,
tnSyncELineRefPriorityOfStationClock Unsigned32,
tnSyncELineRefLockOutOfStationClock TruthValue,
tnSyncELineRefSwStateOfStationClock INTEGER,
tnSyncELineRefCurrentFreqOff Integer32,
tnSyncELineRefAlmProfName OCTET STRING,
tnSyncELineRefIncExtdQLTLVClockID AluWdmPtpClockIdentifier,
tnSyncELineRefIncExtdQLTLVMixedClockType INTEGER,
tnSyncELineRefIncExtdQLTLVPartialChain INTEGER,
tnSyncELineRefIncExtdQLTLVNumeEEC Unsigned32,
tnSyncELineRefIncExtdQLTLVNumEEC Unsigned32,
tnSyncELineRefProvQLOfStationClock Integer32,
tnSyncELineRefIncSSMMsgOfStationClock Integer32,
tnSyncELineRefIncSSMStatusOfStationClock Integer32
}
tnSyncELineRefIndex OBJECT-TYPE
@ -564,12 +648,16 @@ IMPORTS
31 - not applicable
When the NE works in SDH mode:
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
@ -582,6 +670,9 @@ IMPORTS
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
It's applicable only to the timing port with SSM
capabilities."
@ -610,8 +701,7 @@ IMPORTS
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable or disable the line reference incoming QL
processing."
DESCRIPTION "Enable or disable the line reference incoming QL processing."
DEFVAL { disable }
::= { tnSyncELineRefEntry 11 }
@ -622,14 +712,18 @@ IMPORTS
DESCRIPTION "Manually provisioned incoming SSM value for the line
reference. The value can be:
0 - AUTO
0 - AUTO
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
@ -642,9 +736,12 @@ IMPORTS
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled."
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 12 }
@ -701,6 +798,151 @@ IMPORTS
DESCRIPTION "The current frequency offset of the timing reference."
::= { tnSyncELineRefEntry 17 }
tnSyncELineRefAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncELineRefEntry 18 }
tnSyncELineRefIncExtdQLTLVClockID OBJECT-TYPE
SYNTAX AluWdmPtpClockIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Clock ID."
::= { tnSyncELineRefEntry 19 }
tnSyncELineRefIncExtdQLTLVMixedClockType OBJECT-TYPE
SYNTAX INTEGER {
eEECFull(1),
eEECMixedEEC(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Mixed Clock Type Flag."
::= { tnSyncELineRefEntry 20 }
tnSyncELineRefIncExtdQLTLVPartialChain OBJECT-TYPE
SYNTAX INTEGER {
completeChain(1),
partialChain(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Partial Chain Flag."
::= { tnSyncELineRefEntry 21 }
tnSyncELineRefIncExtdQLTLVNumeEEC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Number of eEEC."
::= { tnSyncELineRefEntry 22 }
tnSyncELineRefIncExtdQLTLVNumEEC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Number of EEC."
::= { tnSyncELineRefEntry 23 }
tnSyncELineRefProvQLOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Manually provisioned incoming SSM value
of the line reference output timing.
The value can be:
0 - AUTO
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 24 }
tnSyncELineRefIncSSMMsgOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current value of incoming
QL for output timing on that port.
30 - unstable
31 - not applicable
When the NE works in SDH mode:
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 25 }
tnSyncELineRefIncSSMStatusOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current status of incoming
QL on that port for output timing.
0: Valid
1: Invalid
2: Not Supported
3: Not Applicable
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 26 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Control Table
--------------------------------------------------------------------------------
@ -722,7 +964,7 @@ IMPORTS
TnSyncControlEntry ::=
SEQUENCE {
tnSyncEControlEECEnable INTEGER
tnSyncEControlEECEnable INTEGER
}
tnSyncEControlEECEnable OBJECT-TYPE
@ -795,16 +1037,20 @@ IMPORTS
sts3e(10),
st3(11),
none(12),
dus(13)
dus(13),
ePRTC(23),
pRTC(24),
ePRC(25),
eSEC(26)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec, dnu,
none;
ePRTC, PRTC, ePRC, eSEC, none;
In sonet mode - act, stu, prs, st2, sts3e, st3,
dus, none."
ePRTC, PRTC, ePRC, dus, none."
DEFVAL { act }
::= { tnSyncEPortEntry 2 }
@ -829,22 +1075,24 @@ IMPORTS
TnSyncEStationClockEntry ::=
SEQUENCE {
tnSyncEStationClockSyncMsg TruthValue,
tnSyncEStationClockSyncMsg NokiaSyncStatusMsgType,
tnSyncEStationClockActiveRef INTEGER,
tnSyncEStationClockWTR Unsigned32,
tnSyncEStationClockSwCmdLineRef Unsigned32,
tnSyncEStationClockSystemQL Integer32,
tnSyncEStationClockQLThreshold Integer32,
tnSyncEStationClockOutSel INTEGER
tnSyncEStationClockOutSel INTEGER,
tnSyncEStationClockAlmProfName OCTET STRING
}
tnSyncEStationClockSyncMsg OBJECT-TYPE
SYNTAX TruthValue
SYNTAX NokiaSyncStatusMsgType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Determines if the timing reference selection for
station clock timing uses sync status messaging
(SSM Qualities)."
station clock timing uses Synchronization Status Message
(SSM) Quality Levels or Enhanced Quality Levels."
DEFVAL { false }
::= { tnSyncEStationClockEntry 1 }
tnSyncEStationClockActiveRef OBJECT-TYPE
@ -905,12 +1153,16 @@ IMPORTS
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
@ -922,7 +1174,10 @@ IMPORTS
17 - SMC
18 - ST4
19 - DUS
20 - PNO."
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEStationClockEntry 5}
tnSyncEStationClockQLThreshold OBJECT-TYPE
@ -938,11 +1193,15 @@ IMPORTS
means of using the value DNU or DUS.
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU.
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
@ -953,7 +1212,10 @@ IMPORTS
16 - ST3
17 - SMC
18 - ST4
19 - DUS.
19 - DUS
23 - ePRTC
24 - PRTC
25 - ePRC.
Default value:
SEC - for node working in SDH mode
@ -978,6 +1240,13 @@ IMPORTS
DEFVAL { outtim }
::= { tnSyncEStationClockEntry 7 }
tnSyncEStationClockAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncEStationClockEntry 8 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet BITS Port Table
--------------------------------------------------------------------------------
@ -1005,7 +1274,8 @@ IMPORTS
tnSyncEBITSPortOutputAISMode INTEGER,
tnSyncEBITSPortLineImpedance INTEGER,
tnSyncEBITSPortLineCode INTEGER,
tnSyncEBITSPortLbo INTEGER
tnSyncEBITSPortLbo INTEGER,
tnSyncEBITSPortAlmProfName OCTET STRING
}
tnSyncEBITSPortDirection OBJECT-TYPE
@ -1163,6 +1433,13 @@ IMPORTS
DEFVAL { lbo1 }
::= { tnSyncEBITSPortEntry 8 }
tnSyncEBITSPortAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Alarm profile for BITs port"
::= { tnSyncEBITSPortEntry 9}
--------------------------------------------------------------------------------
-- Wan Table
--------------------------------------------------------------------------------
@ -1230,14 +1507,20 @@ IMPORTS
sts3e(11),
st3(12),
none(13),
dus(14)
dus(14),
ePRTC(23),
pRTC(24),
ePRC(25),
eSEC(26)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec, dnu, none.
In SONET mode - act, prs, stu, st2, st3e, st3, dus, none."
In SDH mode - act, prc, ssua, ssub, sec, dnu,
ePRTC, PRTC, ePRC, eSEC, none.
In SONET mode - act, prs, stu, st2, st3e, st3,
ePRTC, PRTC, ePRC, dus, none."
DEFVAL { act }
::= { tnWanEntry 3 }
@ -1341,7 +1624,8 @@ IMPORTS
tnSyncEClkModState,
tnSyncESystemQL,
tnSyncEQLDegradeThreshold,
tnSyncECurrentActiveLineRefFreqOff
tnSyncECurrentActiveLineRefFreqOff,
tnSyncEAlmProfName
}
STATUS current
DESCRIPTION "."
@ -1364,7 +1648,16 @@ IMPORTS
tnSyncELineRefPriorityOfStationClock,
tnSyncELineRefLockOutOfStationClock,
tnSyncELineRefSwStateOfStationClock,
tnSyncELineRefCurrentFreqOff
tnSyncELineRefCurrentFreqOff,
tnSyncELineRefAlmProfName,
tnSyncELineRefIncExtdQLTLVClockID,
tnSyncELineRefIncExtdQLTLVMixedClockType,
tnSyncELineRefIncExtdQLTLVPartialChain,
tnSyncELineRefIncExtdQLTLVNumeEEC,
tnSyncELineRefIncExtdQLTLVNumEEC,
tnSyncELineRefProvQLOfStationClock,
tnSyncELineRefIncSSMMsgOfStationClock,
tnSyncELineRefIncSSMStatusOfStationClock
}
STATUS current
DESCRIPTION "."
@ -1395,7 +1688,8 @@ IMPORTS
tnSyncEStationClockSwCmdLineRef,
tnSyncEStationClockSystemQL,
tnSyncEStationClockQLThreshold,
tnSyncEStationClockOutSel
tnSyncEStationClockOutSel,
tnSyncEStationClockAlmProfName
}
STATUS current
DESCRIPTION "."
@ -1410,7 +1704,8 @@ IMPORTS
tnSyncEBITSPortOutputAISMode,
tnSyncEBITSPortLineImpedance,
tnSyncEBITSPortLineCode,
tnSyncEBITSPortLbo
tnSyncEBITSPortLbo,
tnSyncEBITSPortAlmProfName
}
STATUS current
DESCRIPTION "."