NEWTEC-REFERENCECLOCK-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-IDENTITY,
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
|
||||
NtcAlarmState
|
||||
FROM NEWTEC-TC-MIB
|
||||
|
||||
ntcFunction
|
||||
FROM NEWTEC-MAIN-MIB;
|
||||
|
||||
|
||||
--
|
||||
-- Module Identification
|
||||
--
|
||||
|
||||
ntcReferenceClock MODULE-IDENTITY
|
||||
LAST-UPDATED "201309200800Z"
|
||||
ORGANIZATION "Newtec Cy"
|
||||
CONTACT-INFO
|
||||
"Newtec Cy
|
||||
Postal: Newtec Cy
|
||||
Laarstraat 5
|
||||
B-9100 Sint-Niklaas
|
||||
Belgium
|
||||
|
||||
Tel: +32 3 780 65 00
|
||||
Fax: +32 3 780 65 49
|
||||
Web: www.newtec.be
|
||||
E-mail: techsupport@newtec.be"
|
||||
DESCRIPTION
|
||||
"Newtec modular reference clock MIB containing definitions for reference clock
|
||||
functionality."
|
||||
|
||||
REVISION "201309200800Z"
|
||||
DESCRIPTION
|
||||
"Lock alarm added"
|
||||
REVISION "201206281200Z"
|
||||
DESCRIPTION
|
||||
"Release for M6100 R1.2"
|
||||
::= { ntcFunction 300 }
|
||||
|
||||
|
||||
--
|
||||
-- Top-Level Structure
|
||||
--
|
||||
|
||||
-- ntcReferenceClock content
|
||||
|
||||
ntcRefClkObjects OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Container holding ntcRefClkObjects definitions."
|
||||
::= { ntcReferenceClock 1 }
|
||||
|
||||
ntcRefClkConformance OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Conformance requirements."
|
||||
::= { ntcReferenceClock 2 }
|
||||
|
||||
-- ntcRefClkObjects content
|
||||
|
||||
ntcRefClkAlarm OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Container holding ntcRefClkAlarm definitions."
|
||||
::= { ntcRefClkObjects 3 }
|
||||
|
||||
-- ntcRefClkConformance content
|
||||
|
||||
ntcRefClkConfCompliance OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Device compliance statements."
|
||||
::= { ntcRefClkConformance 1 }
|
||||
|
||||
ntcRefClkConfGroup OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Groups used by device compliance statements."
|
||||
::= { ntcRefClkConformance 2 }
|
||||
|
||||
|
||||
--
|
||||
-- Managed Objects
|
||||
--
|
||||
|
||||
ntcRefClkRefSelection OBJECT-TYPE
|
||||
SYNTAX INTEGER { internal(0), external(1) }
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The network clock for the devices can be derived from an external reference
|
||||
clock, or from the internal oscillator."
|
||||
DEFVAL { internal }
|
||||
::= { ntcRefClkObjects 1 }
|
||||
|
||||
ntcRefClkExtRefFrequency OBJECT-TYPE
|
||||
SYNTAX INTEGER { e1Mhz(0), e2Mhz(1), e5Mhz(3), e10Mhz(4), e20Mhz(5) }
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Select the frequency of the external reference clock."
|
||||
DEFVAL { e10Mhz }
|
||||
::= { ntcRefClkObjects 2 }
|
||||
|
||||
ntcRefClkAlmRefClockNoSignal OBJECT-TYPE
|
||||
SYNTAX NtcAlarmState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This alarm is raised when no signal is detected on the ReferenceClock input
|
||||
connector. This variable indicates the current status of the alarm."
|
||||
::= { ntcRefClkAlarm 1 }
|
||||
|
||||
ntcRefClkAlmRefClockNoLock OBJECT-TYPE
|
||||
SYNTAX NtcAlarmState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This alarm is raised when the device cannot lock on the reference clock. This
|
||||
variable indicates the current status of the alarm."
|
||||
::= { ntcRefClkAlarm 2 }
|
||||
|
||||
ntcRefClkActiveRef OBJECT-TYPE
|
||||
SYNTAX INTEGER { internal(0), external(1) }
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The network clock for the devices can be derived from an external reference
|
||||
clock, or from the internal oscillator."
|
||||
::= { ntcRefClkObjects 4 }
|
||||
|
||||
|
||||
--
|
||||
-- Module Conformance
|
||||
--
|
||||
|
||||
ntcRefClkConfGrpV1Standard OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ntcRefClkRefSelection,
|
||||
ntcRefClkExtRefFrequency,
|
||||
ntcRefClkAlmRefClockNoSignal,
|
||||
ntcRefClkAlmRefClockNoLock,
|
||||
ntcRefClkActiveRef
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Managed objects that constitute version 1 of a system device with standard capabilities."
|
||||
::= { ntcRefClkConfGroup 1}
|
||||
|
||||
ntcRefClkConfCompV1Standard MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Compliance statement for Newtec device MIB implementations."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS
|
||||
{
|
||||
ntcRefClkConfGrpV1Standard
|
||||
}
|
||||
::= { ntcRefClkConfCompliance 1 }
|
||||
|
||||
|
||||
END
|