CUMULUS-SENSOR-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32, Unsigned32, mib-2
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TEXTUAL-CONVENTION, TimeStamp
|
||||
FROM SNMPv2-TC
|
||||
SnmpAdminString
|
||||
FROM SNMP-FRAMEWORK-MIB
|
||||
cumulusMib
|
||||
FROM CUMULUS-SNMP-MIB;
|
||||
|
||||
agentSwitchSensorMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200212160000Z"
|
||||
ORGANIZATION "Cumulus sensor MIB"
|
||||
CONTACT-INFO
|
||||
"Nvidia Cumulus"
|
||||
DESCRIPTION
|
||||
"Cumulus entity sensor mib based on ENTITY-SENSOR-MIB"
|
||||
|
||||
::= { cumulusMib 6 }
|
||||
|
||||
entitySensorObjects OBJECT IDENTIFIER
|
||||
::= { agentSwitchSensorMIB 1 }
|
||||
|
||||
--
|
||||
-- Textual Conventions
|
||||
--
|
||||
|
||||
EntitySensorDataType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents the Entity Sensor
|
||||
measurement data type associated with a physical sensor
|
||||
value. The actual data units are determined by examining an
|
||||
object of this type together with the associated
|
||||
EntitySensorDataScale object.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataScale and
|
||||
EntitySensorPrecision. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue.
|
||||
|
||||
Valid values are:
|
||||
|
||||
other(1): a measure other than those listed below
|
||||
unknown(2): unknown measurement, or arbitrary,
|
||||
relative numbers
|
||||
voltsAC(3): electric potential
|
||||
voltsDC(4): electric potential
|
||||
amperes(5): electric current
|
||||
watts(6): power
|
||||
hertz(7): frequency
|
||||
celsius(8): temperature
|
||||
percentRH(9): percent relative humidity
|
||||
rpm(10): shaft revolutions per minute
|
||||
cmm(11),: cubic meters per minute (airflow)
|
||||
truthvalue(12): value takes { true(1), false(2) }
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
unknown(2),
|
||||
voltsAC(3),
|
||||
voltsDC(4),
|
||||
amperes(5),
|
||||
watts(6),
|
||||
hertz(7),
|
||||
celsius(8),
|
||||
percentRH(9),
|
||||
rpm(10),
|
||||
cmm(11),
|
||||
truthvalue(12)
|
||||
}
|
||||
|
||||
EntitySensorDataScale ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents a data scaling
|
||||
factor, represented with an International System of Units
|
||||
(SI) prefix. The actual data units are determined by
|
||||
examining an object of this type together with the
|
||||
associated EntitySensorDataType object.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType and
|
||||
EntitySensorPrecision. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue."
|
||||
REFERENCE
|
||||
"The International System of Units (SI),
|
||||
National Institute of Standards and Technology,
|
||||
Spec. Publ. 330, August 1991."
|
||||
SYNTAX INTEGER {
|
||||
yocto(1), -- 10^-24
|
||||
zepto(2), -- 10^-21
|
||||
atto(3), -- 10^-18
|
||||
femto(4), -- 10^-15
|
||||
pico(5), -- 10^-12
|
||||
nano(6), -- 10^-9
|
||||
micro(7), -- 10^-6
|
||||
milli(8), -- 10^-3
|
||||
units(9), -- 10^0
|
||||
kilo(10), -- 10^3
|
||||
mega(11), -- 10^6
|
||||
giga(12), -- 10^9
|
||||
tera(13), -- 10^12
|
||||
exa(14), -- 10^15
|
||||
peta(15), -- 10^18
|
||||
zetta(16), -- 10^21
|
||||
yotta(17) -- 10^24
|
||||
}
|
||||
|
||||
EntitySensorPrecision ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents a sensor
|
||||
precision range.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType and
|
||||
EntitySensorDataScale. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue.
|
||||
|
||||
If an object of this type contains a value in the range 1 to
|
||||
9, it represents the number of decimal places in the
|
||||
fractional part of an associated EntitySensorValue fixed-
|
||||
point number.
|
||||
|
||||
If an object of this type contains a value in the range -8
|
||||
to -1, it represents the number of accurate digits in the
|
||||
associated EntitySensorValue fixed-point number.
|
||||
|
||||
The value zero indicates the associated EntitySensorValue
|
||||
object is not a fixed-point number.
|
||||
|
||||
Agent implementors must choose a value for the associated
|
||||
EntitySensorPrecision object so that the precision and
|
||||
|
||||
accuracy of the associated EntitySensorValue object is
|
||||
correctly indicated.
|
||||
|
||||
For example, a physical entity representing a temperature
|
||||
sensor that can measure 0 degrees to 100 degrees C in 0.1
|
||||
degree increments, +/- 0.05 degrees, would have an
|
||||
EntitySensorPrecision value of '1', an EntitySensorDataScale
|
||||
value of 'units(9)', and an EntitySensorValue ranging from
|
||||
'0' to '1000'. The EntitySensorValue would be interpreted
|
||||
as 'degrees C * 10'."
|
||||
SYNTAX Integer32 (-8..9)
|
||||
|
||||
EntitySensorValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents an Entity Sensor
|
||||
value.
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType, EntitySensorDataScale
|
||||
and EntitySensorPrecision. Together, associated objects of
|
||||
those three types are used to identify the semantics of an
|
||||
object of this data type.
|
||||
|
||||
The semantics of an object using this data type are
|
||||
determined by the value of the associated
|
||||
EntitySensorDataType object.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6),
|
||||
'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of
|
||||
this type MUST contain a fixed point number ranging from
|
||||
-999,999,999 to +999,999,999. The value -1000000000
|
||||
indicates an underflow error. The value +1000000000
|
||||
indicates an overflow error. The EntitySensorPrecision
|
||||
indicates how many fractional digits are represented in the
|
||||
associated EntitySensorValue object.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'percentRH(9)', then an object of this type MUST contain a
|
||||
number ranging from 0 to 100.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'rpm(10)', then an object of this type MUST contain a number
|
||||
ranging from -999,999,999 to +999,999,999.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'truthvalue(12)', then an object of this type MUST contain
|
||||
either the value 'true(1)' or the value 'false(2)'.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'other(1)' or unknown(2)', then an object of this type MUST
|
||||
contain a number ranging from -1000000000 to 1000000000."
|
||||
SYNTAX Integer32 (-1000000000..1000000000)
|
||||
|
||||
EntitySensorStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents the operational
|
||||
status of a physical sensor.
|
||||
|
||||
The value 'ok(1)' indicates that the agent can obtain the
|
||||
sensor value.
|
||||
|
||||
The value 'unavailable(2)' indicates that the agent
|
||||
presently cannot obtain the sensor value.
|
||||
|
||||
The value 'nonoperational(3)' indicates that the agent
|
||||
believes the sensor is broken. The sensor could have a hard
|
||||
failure (disconnected wire), or a soft failure such as out-
|
||||
of-range, jittery, or wildly fluctuating readings."
|
||||
SYNTAX INTEGER {
|
||||
ok(1),
|
||||
unavailable(2),
|
||||
nonoperational(3)
|
||||
}
|
||||
|
||||
EntitySensorAlarm ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This enumerated data type provides
|
||||
information about alarm
|
||||
Valid values are:
|
||||
|
||||
normal(3),
|
||||
warning(4),
|
||||
alert(5),
|
||||
critical(6)
|
||||
"
|
||||
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
unknown(2),
|
||||
normal(3),
|
||||
warning(4),
|
||||
alert(5),
|
||||
critical(6),
|
||||
NotPresent(7),
|
||||
NotOperational(8),
|
||||
unavailable(9)
|
||||
}
|
||||
|
||||
EntityAdminStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This enumerated data type
|
||||
provides adiministrative state
|
||||
on(1)
|
||||
off(0)"
|
||||
SYNTAX INTEGER {
|
||||
off(0),
|
||||
on(1),
|
||||
notApplicable(2)
|
||||
}
|
||||
|
||||
--
|
||||
-- Entity Sensor Table
|
||||
--
|
||||
|
||||
entPhySensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EntPhySensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per physical sensor represented
|
||||
by an associated row in the entPhysicalTable."
|
||||
::= { entitySensorObjects 1 }
|
||||
|
||||
entPhySensorEntry OBJECT-TYPE
|
||||
SYNTAX EntPhySensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular physical sensor.
|
||||
|
||||
An entry in this table describes the present reading of a
|
||||
sensor, the measurement units and scale, and sensor
|
||||
operational status.
|
||||
|
||||
Entries are created in this table by the agent. An entry
|
||||
for each physical sensor SHOULD be created at the same time
|
||||
as the associated entPhysicalEntry. An entry SHOULD be
|
||||
destroyed if the associated entPhysicalEntry is destroyed."
|
||||
INDEX {entPhySensorIndex}
|
||||
::= { entPhySensorTable 1 }
|
||||
|
||||
EntPhySensorEntry ::= SEQUENCE {
|
||||
entPhySensorIndex Integer32,
|
||||
entPhySensorType EntitySensorDataType,
|
||||
entPhySensorScale EntitySensorDataScale,
|
||||
entPhySensorPrecision EntitySensorPrecision,
|
||||
entPhySensorValue EntitySensorValue,
|
||||
entPhySensorOperStatus EntitySensorStatus,
|
||||
entPhySensorUnitsDisplay SnmpAdminString,
|
||||
entPhySensorValueTimeStamp TimeStamp,
|
||||
entPhySensorValueUpdateRate Unsigned32,
|
||||
entPhySensorDescr SnmpAdminString,
|
||||
entPhySensorMin EntitySensorValue,
|
||||
entPhySensorMax EntitySensorValue,
|
||||
entPhySensorAlarm EntitySensorAlarm,
|
||||
entPhySensorAdminStatus EntityAdminStatus
|
||||
}
|
||||
|
||||
entPhySensorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Sensor Identifier"
|
||||
::= { entPhySensorEntry 1 }
|
||||
|
||||
entPhySensorType OBJECT-TYPE
|
||||
SYNTAX EntitySensorDataType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of data returned by the associated
|
||||
entPhySensorValue object.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 2 }
|
||||
|
||||
entPhySensorScale OBJECT-TYPE
|
||||
SYNTAX EntitySensorDataScale
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The exponent to apply to values returned by the associated
|
||||
entPhySensorValue object.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 3 }
|
||||
|
||||
entPhySensorPrecision OBJECT-TYPE
|
||||
SYNTAX EntitySensorPrecision
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of decimal places of precision in fixed-point
|
||||
sensor values returned by the associated entPhySensorValue
|
||||
object.
|
||||
|
||||
This object SHOULD be set to '0' when the associated
|
||||
entPhySensorType value is not a fixed-point type: e.g.,
|
||||
'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 4 }
|
||||
|
||||
entPhySensorValue OBJECT-TYPE
|
||||
SYNTAX EntitySensorValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The most recent measurement obtained by the agent for this
|
||||
sensor.
|
||||
|
||||
To correctly interpret the value of this object, the
|
||||
associated entPhySensorType, entPhySensorScale, and
|
||||
entPhySensorPrecision objects must also be examined."
|
||||
::= { entPhySensorEntry 5 }
|
||||
|
||||
entPhySensorOperStatus OBJECT-TYPE
|
||||
SYNTAX EntitySensorStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational status of the sensor."
|
||||
::= { entPhySensorEntry 6 }
|
||||
|
||||
entPhySensorUnitsDisplay OBJECT-TYPE
|
||||
SYNTAX SnmpAdminString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of the data units that should be used
|
||||
in the display of entPhySensorValue."
|
||||
::= { entPhySensorEntry 7 }
|
||||
|
||||
entPhySensorValueTimeStamp OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime at the time the status and/or value
|
||||
of this sensor was last obtained by the agent."
|
||||
::= { entPhySensorEntry 8 }
|
||||
|
||||
entPhySensorValueUpdateRate OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "milliseconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of the frequency that the agent updates the
|
||||
associated entPhySensorValue object, representing in
|
||||
milliseconds.
|
||||
|
||||
The value zero indicates:
|
||||
|
||||
- the sensor value is updated on demand (e.g.,
|
||||
when polled by the agent for a get-request),
|
||||
- the sensor value is updated when the sensor
|
||||
value changes (event-driven),
|
||||
- the agent does not know the update rate.
|
||||
"
|
||||
::= { entPhySensorEntry 9 }
|
||||
|
||||
entPhySensorDescr OBJECT-TYPE
|
||||
SYNTAX SnmpAdminString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of physical entity. This object
|
||||
should contain a string that identifies the manufacturer's
|
||||
name for the physical entity, and should be set to a
|
||||
distinct value for each version or model of the physical
|
||||
entity."
|
||||
::= { entPhySensorEntry 10 }
|
||||
|
||||
entPhySensorMin OBJECT-TYPE
|
||||
SYNTAX EntitySensorValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Minimum value expected of the sensor. Provided by
|
||||
manufacturer"
|
||||
::= { entPhySensorEntry 11 }
|
||||
|
||||
entPhySensorMax OBJECT-TYPE
|
||||
SYNTAX EntitySensorValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum value expected of the sensor. Provided by
|
||||
manufacturer"
|
||||
::= { entPhySensorEntry 12 }
|
||||
|
||||
entPhySensorAlarm OBJECT-TYPE
|
||||
SYNTAX EntitySensorAlarm
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Sensor value translates into the levels of alarm"
|
||||
::= { entPhySensorEntry 13 }
|
||||
|
||||
entPhySensorAdminStatus OBJECT-TYPE
|
||||
SYNTAX EntityAdminStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Admin status of the sensor."
|
||||
::= { entPhySensorEntry 14 }
|
||||
|
||||
END
|