Commit version 24.12.13800
This commit is contained in:
136
mibs/cambium/CAMBIUM-NETWORKS-RPS-MIB
Normal file
136
mibs/cambium/CAMBIUM-NETWORKS-RPS-MIB
Normal file
@ -0,0 +1,136 @@
|
||||
CAMBIUM-NETWORKS-RPS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
||||
Unsigned32, Integer32, Counter32, enterprises
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
SnmpAdminString
|
||||
FROM SNMP-FRAMEWORK-MIB
|
||||
ifIndex
|
||||
FROM IF-MIB
|
||||
RowStatus, TruthValue
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
cnRPSMib MODULE-IDENTITY
|
||||
LAST-UPDATED "202209082000Z" -- September 08, 2022
|
||||
ORGANIZATION "Cambium Networks, Inc."
|
||||
CONTACT-INFO "cambiumnetworks.com"
|
||||
DESCRIPTION
|
||||
"This MIB module contains objects related to the
|
||||
Removable Power Supply support."
|
||||
|
||||
REVISION "202209082000Z" -- September 08, 2022
|
||||
DESCRIPTION "Ver 2: Add cnRPSCurrentInputVoltage"
|
||||
REVISION "202007030000Z" -- July 03, 2020
|
||||
DESCRIPTION "Ver 1: Initial version."
|
||||
|
||||
::= { enterprises 17713 24 6 }
|
||||
|
||||
--
|
||||
-- Removable Power Supply attributes
|
||||
--
|
||||
|
||||
cnRPSTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CnRPSTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"RPS entry"
|
||||
|
||||
::= { cnRPSMib 1 }
|
||||
|
||||
cnRPSTableEntry OBJECT-TYPE
|
||||
SYNTAX CnRPSTableEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Port-specific data related to the transceivers"
|
||||
|
||||
INDEX { cnRPSIndex }
|
||||
::= { cnRPSTable 1 }
|
||||
|
||||
CnRPSTableEntry ::= SEQUENCE {
|
||||
cnRPSIndex Integer32,
|
||||
cnRPSMaximumVoltage Integer32,
|
||||
cnRPSMaximumCurrent Integer32,
|
||||
cnRPSMaximumWatts Integer32,
|
||||
cnRPSStatus INTEGER,
|
||||
cnRPSCurrentInputVoltage Integer32
|
||||
}
|
||||
|
||||
cnRPSIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"RPS index identifier attribute"
|
||||
|
||||
::= { cnRPSTableEntry 1 }
|
||||
|
||||
cnRPSMaximumVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum voltage of power supply."
|
||||
|
||||
::= { cnRPSTableEntry 2 }
|
||||
|
||||
cnRPSMaximumCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "amps"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum current of power supply."
|
||||
|
||||
::= { cnRPSTableEntry 3 }
|
||||
|
||||
cnRPSMaximumWatts OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "watts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Maximum watts of power supply."
|
||||
|
||||
::= { cnRPSTableEntry 4 }
|
||||
|
||||
cnRPSStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
ok(1),
|
||||
error(2),
|
||||
notpresent(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status of power supply."
|
||||
|
||||
::= { cnRPSTableEntry 5 }
|
||||
|
||||
cnRPSCurrentInputVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "volts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current input voltage applied to the power supply."
|
||||
|
||||
::= { cnRPSTableEntry 6 }
|
||||
|
||||
cnRPSTrapMsg NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
cnRPSMaximumWatts,
|
||||
cnRPSStatus,
|
||||
cnRPSIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is sent out whenever a status change occurs on a power supply."
|
||||
::= { cnRPSMib 2 }
|
||||
|
||||
END
|
Reference in New Issue