Commit version 24.12.13800
This commit is contained in:
762
mibs/adtran/ADTRAN-TA5K-REDUNDANCY-MIB
Normal file
762
mibs/adtran/ADTRAN-TA5K-REDUNDANCY-MIB
Normal file
@ -0,0 +1,762 @@
|
||||
ADTRAN-TA5K-REDUNDANCY-MIB
|
||||
|
||||
DEFINITIONS ::= BEGIN
|
||||
|
||||
-- TITLE: The ADTRAN Total Access TA5000 Redundancy MIB
|
||||
-- PRODUCT: 1187020L1, 1187800L1, 1187300L1
|
||||
-- VERSION: 1.0
|
||||
-- DATE: April 15, 2006
|
||||
|
||||
-- This MIB Contains tables specific to the TA5000 Redundancy
|
||||
--
|
||||
|
||||
-- MIBs supported:
|
||||
|
||||
-- HISTORY:
|
||||
-- 04/18/06 tpm First edition
|
||||
-- 04/19/06 tpm Module identiy inherits from adIdentityShared, and mgmt objects are in adShared,
|
||||
-- RedundancyTable renamed to EquipmentRedundancy
|
||||
-- 05/06/08 aed Add two new alarm notifications: protection unavailable and card active.
|
||||
-- 06/05/08 aed Correct errors found during SMICng compile
|
||||
-- 11/05/08 aed Change the severity for three alarms. Peer version mismatch, Remote Db Sync,
|
||||
-- and Db Mirroring traps are all warnings.
|
||||
-- 01/27/09 aed Add new manual-switch notification.
|
||||
-- 03/17/09 rp Added SNMP Support for the Eqpt APS On Alarm. Added the Active and Clear version of the OIDS.
|
||||
-- 07/10/09 nra Added new Automatic Switch notification
|
||||
-- 02/18/10 glf Added Alarm Provisioning to allow enable/disable of redundancy alarms
|
||||
-- **** DO NOT ADD REVISION HISTORY HERE ****
|
||||
|
||||
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Integer32,
|
||||
Counter32,
|
||||
IpAddress,
|
||||
-- Gauge32,
|
||||
-- Counter64,
|
||||
-- TimeTicks,
|
||||
-- Unsigned32,
|
||||
NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
sysName
|
||||
FROM SNMPv2-MIB
|
||||
|
||||
ifIndex
|
||||
-- InterfaceIndexOrZero,
|
||||
-- InterfaceIndex
|
||||
FROM IF-MIB
|
||||
|
||||
DisplayString,
|
||||
TruthValue,
|
||||
RowStatus,
|
||||
-- TimeInterval,
|
||||
MacAddress,
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
|
||||
-- SnmpAdminString
|
||||
-- FROM SNMP-FRAMEWORK-MIB
|
||||
|
||||
adIdentity,
|
||||
adIdentityShared,
|
||||
adProducts,
|
||||
adMgmt
|
||||
FROM ADTRAN-MIB
|
||||
|
||||
adGenTa5kRedundancy,
|
||||
adGenTa5kRedundancyID
|
||||
FROM ADTRAN-GENTA5K-MIB
|
||||
|
||||
-- IANAifType
|
||||
-- FROM IANAifType-MIB
|
||||
|
||||
adTrapInformSeqNum
|
||||
FROM ADTRAN-GENTRAPINFORM-MIB
|
||||
|
||||
adGenSlotInfoIndex
|
||||
FROM ADTRAN-GENSLOT-MIB;
|
||||
|
||||
-- *********************************************************************************************************
|
||||
|
||||
adTa5kRedundancyModuleIdentity MODULE-IDENTITY
|
||||
LAST-UPDATED "201110121400Z"
|
||||
ORGANIZATION
|
||||
"ADTRAN, Inc."
|
||||
CONTACT-INFO
|
||||
"CND Tech Support
|
||||
Postal: ADTRAN, Inc.
|
||||
901 Explorer Blvd.
|
||||
Huntsville, AL 35806
|
||||
Tel: +1 800 726-8663
|
||||
Fax: +1 256 963 6217
|
||||
E-mail: support@adtran.com"
|
||||
DESCRIPTION
|
||||
"Total Access 5000 Redundancy MIB"
|
||||
|
||||
REVISION "201110121400Z"
|
||||
DESCRIPTION "Add Standby Not Ready Reasons Table"
|
||||
::= { adGenTa5kRedundancyID 1 }
|
||||
|
||||
-- OBJECT IDENTIFIERS
|
||||
adTa5kEquipmentRedundancy OBJECT IDENTIFIER ::= { adGenTa5kRedundancy 1 }
|
||||
adTa5kFacilityRedundancy OBJECT IDENTIFIER ::= { adGenTa5kRedundancy 2 }
|
||||
adTa5kRedundancyAlarmPrefix OBJECT IDENTIFIER ::= { adGenTa5kRedundancy 3 }
|
||||
adTa5kRedundancyAlarmProv OBJECT IDENTIFIER ::= { adGenTa5kRedundancy 4 }
|
||||
adTa5kRedundancyAlarms OBJECT IDENTIFIER ::= { adTa5kRedundancyAlarmPrefix 0}
|
||||
|
||||
|
||||
adTa5kEquipmentRedundancyTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdTa5kEquipmentRedundancyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"..."
|
||||
::= { adTa5kEquipmentRedundancy 1 }
|
||||
|
||||
adTa5kEquipmentRedundancyEntry OBJECT-TYPE
|
||||
SYNTAX AdTa5kEquipmentRedundancyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"..."
|
||||
INDEX { adGenSlotInfoIndex }
|
||||
::= { adTa5kEquipmentRedundancyTable 1 }
|
||||
|
||||
AdTa5kEquipmentRedundancyEntry ::=
|
||||
SEQUENCE {
|
||||
adTa5kEquipmentRedundancySupported INTEGER,
|
||||
adTa5kEquipmentRedundancyRevertive INTEGER,
|
||||
adTa5kEquipmentRedundancyRevertiveTimeout Integer32,
|
||||
adTa5kEquipmentRedundancyForceFailover INTEGER,
|
||||
adTa5kEquipmentRedundancyState INTEGER,
|
||||
adTa5kEquipmentRedundancyPeerSlot Integer32,
|
||||
adTa5kEquipmentRedundancyFeatureEnabled INTEGER,
|
||||
adTa5kEquipmentRedundancyFacilityType INTEGER,
|
||||
adTa5kEquipmentRedundancyStandbyReasonsCount Integer32
|
||||
}
|
||||
|
||||
adTa5kEquipmentRedundancySupported OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
true (1),
|
||||
peerNotResponding (2),
|
||||
peerIncompatible (3),
|
||||
peerNotPresent (4),
|
||||
peerNotReady (5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Supported means this unit will be able to failover to a standby card.
|
||||
if it is not true, the value returns a reason why the unit cannot failover.
|
||||
Valid for the active unit only."
|
||||
::= { adTa5kEquipmentRedundancyEntry 1 }
|
||||
|
||||
adTa5kEquipmentRedundancyRevertive OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable (1),
|
||||
disable (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable the property of a protected unit reverting back to the original
|
||||
operating unit when the original unit's health has returned to normal operating status.
|
||||
Enabled will revert (after a timeout default=15s).
|
||||
Disabled will leave the second unit acting as the active and the first unit will be the standby.
|
||||
Valid for the active unit only."
|
||||
::= { adTa5kEquipmentRedundancyEntry 2 }
|
||||
|
||||
adTa5kEquipmentRedundancyRevertiveTimeout OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Time in seconds to wait before allowing a protection switch to revert back to the primary unit.
|
||||
Valid for the active unit only."
|
||||
::= { adTa5kEquipmentRedundancyEntry 3 }
|
||||
|
||||
adTa5kEquipmentRedundancyForceFailover OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
failover (1),
|
||||
notapplicable (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this to failover(1) will swap the active and standby status of the redundant modules.
|
||||
Valid for the active unit only."
|
||||
::= { adTa5kEquipmentRedundancyEntry 4 }
|
||||
|
||||
adTa5kEquipmentRedundancyState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
active (1),
|
||||
standby (2),
|
||||
standbyNotReady (3),
|
||||
notApplicable (4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Equipment Redundancy State.
|
||||
StandbyNotReady means the unit is the standby, but cannot accept a failover should one occur.
|
||||
This case occurs when the standby is booting up, or not syncronized with provisioning from the active."
|
||||
::= { adTa5kEquipmentRedundancyEntry 5 }
|
||||
|
||||
adTa5kEquipmentRedundancyPeerSlot OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Slot number of the peer."
|
||||
::= { adTa5kEquipmentRedundancyEntry 6 }
|
||||
|
||||
adTa5kEquipmentRedundancyFeatureEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(0),
|
||||
enabled(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enabled if the card is provisioned to operate rendundantly if possible. Disabled
|
||||
if the card if provisioned for non-redundant operation only."
|
||||
::= { adTa5kEquipmentRedundancyEntry 7 }
|
||||
|
||||
adTa5kEquipmentRedundancyFacilityType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
sharedFacilities(0),
|
||||
dualFacilities(1),
|
||||
separateFacilities(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shared Facilities: redundant modules share a physical cable/fiber ('y-cable')
|
||||
Dual Facilities: redundant modules have independent redundant cable/fiber facilities
|
||||
Separate Facilites: modules and cable/fiber facilities are not redundant"
|
||||
::= { adTa5kEquipmentRedundancyEntry 8 }
|
||||
|
||||
adTa5kEquipmentRedundancyStandbyReasonsCount OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Returns a count of the number of rows in the StandbyNotReadyReasonsTable."
|
||||
::= { adTa5kEquipmentRedundancyEntry 9 }
|
||||
|
||||
adTa5kStandbyNotReadyReasonsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdTa5kStandbyNotReadyReasonEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table lists the reasons why a module is in the StandbyNotReady state"
|
||||
::= { adTa5kEquipmentRedundancy 3 }
|
||||
|
||||
adTa5kStandbyNotReadyReasonEntry OBJECT-TYPE
|
||||
SYNTAX AdTa5kStandbyNotReadyReasonEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the StandbyNotReadyReasonsTable"
|
||||
INDEX { adGenSlotInfoIndex, adTa5kStandbyNotReadyReasonIndex }
|
||||
::= { adTa5kStandbyNotReadyReasonsTable 1 }
|
||||
|
||||
AdTa5kStandbyNotReadyReasonEntry ::=
|
||||
SEQUENCE {
|
||||
adTa5kStandbyNotReadyReasonIndex Integer32,
|
||||
adTa5kStandbyNotReadyReason DisplayString
|
||||
}
|
||||
|
||||
adTa5kStandbyNotReadyReasonIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "A unique index for each StandbyNotReady reason.
|
||||
Values range from 1 to adTa5kEquipmentRedundancyStandbyReasonsCount"
|
||||
::= { adTa5kStandbyNotReadyReasonEntry 1 }
|
||||
|
||||
adTa5kStandbyNotReadyReason OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Returns the reason for the StandbyNotReady state."
|
||||
::= { adTa5kStandbyNotReadyReasonEntry 2 }
|
||||
|
||||
-- *********************************************************************************************************
|
||||
-- ********************** Facility *********************************************************************
|
||||
-- *********************************************************************************************************
|
||||
|
||||
adTa5kFacilityRedundancyTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdTa5kFacilityRedundancyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table is valid for the active unit only."
|
||||
::= { adTa5kFacilityRedundancy 1 }
|
||||
|
||||
adTa5kFacilityRedundancyEntry OBJECT-TYPE
|
||||
SYNTAX AdTa5kFacilityRedundancyEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"..."
|
||||
INDEX { ifIndex }
|
||||
::= { adTa5kFacilityRedundancyTable 1 }
|
||||
|
||||
AdTa5kFacilityRedundancyEntry ::=
|
||||
SEQUENCE {
|
||||
adTa5kFacilityRedundancySupported INTEGER,
|
||||
adTa5kFacilityRedundancyState INTEGER,
|
||||
adTa5kFacilityRedundancyForceProtect Integer32,
|
||||
adTa5kFacilityRedundancyProtectedByIfIndex Integer32
|
||||
}
|
||||
|
||||
adTa5kFacilityRedundancySupported OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
protected (1),
|
||||
redundantFacilityNotPresent (2),
|
||||
redundantFacilityNotCompatible (3),
|
||||
redundantFacilityAdminDown (4),
|
||||
redundantFacilityLinkDown (5),
|
||||
redundantFacilityInUse (6),
|
||||
redundantEquipmentAdminDown (7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { adTa5kFacilityRedundancyEntry 1 }
|
||||
|
||||
adTa5kFacilityRedundancyState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
active (1),
|
||||
standby (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { adTa5kFacilityRedundancyEntry 2 }
|
||||
|
||||
adTa5kFacilityRedundancyForceProtect OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { adTa5kFacilityRedundancyEntry 3 }
|
||||
|
||||
adTa5kFacilityRedundancyProtectedByIfIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { adTa5kFacilityRedundancyEntry 4 }
|
||||
-- ******************************************************************************************
|
||||
-- Alarm Provisioning
|
||||
-- ******************************************************************************************
|
||||
|
||||
adTa5kRedundancyAlarmProvTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdTa5kRedundancyAlarmProvEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"..."
|
||||
::= { adTa5kRedundancyAlarmProv 1 }
|
||||
|
||||
adTa5kRedundancyAlarmProvEntry OBJECT-TYPE
|
||||
SYNTAX AdTa5kRedundancyAlarmProvEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"..."
|
||||
INDEX { adGenSlotInfoIndex }
|
||||
::= { adTa5kRedundancyAlarmProvTable 1 }
|
||||
|
||||
AdTa5kRedundancyAlarmProvEntry ::=
|
||||
SEQUENCE {
|
||||
adTa5kRedundancyAlarmProvCardActiveEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvProtectionUnavailableEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvPeerCodeVersionMismatchEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvPeerDbMirroringSyncInProgressEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvPeerRemoteDatabaseSyncInProgressEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvManualSwitchEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvSwitchToProtectEnable TruthValue,
|
||||
adTa5kRedundancyAlarmProvAutomaticSwitchEnable TruthValue
|
||||
|
||||
}
|
||||
|
||||
adTa5kRedundancyAlarmProvCardActiveEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 1 }
|
||||
|
||||
adTa5kRedundancyAlarmProvProtectionUnavailableEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 2 }
|
||||
|
||||
adTa5kRedundancyAlarmProvPeerCodeVersionMismatchEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 3 }
|
||||
|
||||
adTa5kRedundancyAlarmProvPeerDbMirroringSyncInProgressEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 4 }
|
||||
|
||||
adTa5kRedundancyAlarmProvPeerRemoteDatabaseSyncInProgressEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 5 }
|
||||
|
||||
adTa5kRedundancyAlarmProvManualSwitchEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 6 }
|
||||
|
||||
adTa5kRedundancyAlarmProvSwitchToProtectEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 7 }
|
||||
|
||||
adTa5kRedundancyAlarmProvAutomaticSwitchEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"True - alarm is enabled"
|
||||
|
||||
DEFVAL {true}
|
||||
|
||||
::= { adTa5kRedundancyAlarmProvEntry 8 }
|
||||
|
||||
-- ******************************************************************************************
|
||||
-- Alarms
|
||||
-- ******************************************************************************************
|
||||
adTa5kRedundancyCardActive NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the standby card in redundant pair has become the active module."
|
||||
|
||||
--#TYPE "Status - Card Active"
|
||||
--#SUMMARY "Redundancy: Card Active on"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d"
|
||||
--#ARGUMENTS {1, 2}
|
||||
--#SEVERITY WARNING
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 1 }
|
||||
|
||||
adTa5kRedundancyProtectionAvailable NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Redundancy protection is available for this slot."
|
||||
|
||||
--#TYPE "Minor - Protection Unavailable - Cleared"
|
||||
--#SUMMARY "Protection Unavailable - Cleared"
|
||||
--#SUMMARY "cleared at shelf: %s, slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "MINOR"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Alarm Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= {adTa5kRedundancyAlarms 2}
|
||||
|
||||
adTa5kRedundancyProtectionUnavailable NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Redundancy protection is not available for this slot."
|
||||
|
||||
|
||||
--#TYPE "Minor - Protection Unavailable - Active"
|
||||
--#SUMMARY "Protection Unavailable - Active"
|
||||
--#SUMMARY "detected at shelf: %s, slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "MINOR"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Alarm Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= {adTa5kRedundancyAlarms 3}
|
||||
|
||||
adTa5kRedundancyPeerCodeVersionMismatchClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the Active module code version mismatch with its peer has cleared."
|
||||
|
||||
--#TYPE "Status - xM Peer Code Version Mismatch Clear"
|
||||
--#SUMMARY "TA5000 Module: Peer Code Version Alarm Cleared on"
|
||||
--#SUMMARY "Shelf: %s , slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 4 }
|
||||
|
||||
adTa5kRedundancyPeerCodeVersionMismatch NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the Active module code version does not match with its peer."
|
||||
--#TYPE "Status - xM Peer Code Version Mismatch"
|
||||
--#SUMMARY "TA5000 module: Peer Code Version Mismatch Alarm on"
|
||||
--#SUMMARY "Shelf: %s , slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 5 }
|
||||
|
||||
|
||||
adTa5kRedundancyPeerDatabaseMirroringInSync NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the xM's peer database mirroring is in sync."
|
||||
|
||||
--#TYPE "Status - xM Database Mirroring In Sync"
|
||||
--#SUMMARY "TA5000 Module: Database Mirroring In Sync"
|
||||
--#SUMMARY "Shelf: %s, slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 6 }
|
||||
|
||||
adTa5kRedundancyPeerDbMirroringSyncInProgress NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the peer database mirroring sync is in progress on the xM."
|
||||
|
||||
--#TYPE "Status - xM Database Mirroring Sync In Progress"
|
||||
--#SUMMARY "TA5000 Module: Database Mirroring Sync In Progress"
|
||||
--#SUMMARY "Shelf: %s , slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 7 }
|
||||
|
||||
|
||||
adTa5kRedundancyPeerRemoteDatabaseSyncInProgress NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the peer remote database sync is in progress on the SM."
|
||||
|
||||
--#TYPE "Status - xM Remote Database Sync In Progress"
|
||||
--#SUMMARY "TA5000 Module: Remote Database Sync In Progress on"
|
||||
--#SUMMARY "Shelf: %s , slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 8 }
|
||||
|
||||
adTa5kRedundancyPeerRemoteDatabaseInSync NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the xM's remote database is in sync."
|
||||
|
||||
--#TYPE "Status - xM Remote Database In Sync"
|
||||
--#SUMMARY "TA5000 Module: Remote Database In Sync on"
|
||||
--#SUMMARY "Shelf: %s , slot: %d"
|
||||
--#ARGUMENTS {1,2}
|
||||
--#SEVERITY "WARNING"
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 9 }
|
||||
|
||||
adTa5kRedundancyManualSwitch NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the user has initiated a manual protection switch."
|
||||
|
||||
--#TYPE "Status - Manual Switch"
|
||||
--#SUMMARY "Redundancy: Request for Manual Switch"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d"
|
||||
--#ARGUMENTS {1, 2}
|
||||
--#SEVERITY WARNING
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 10 }
|
||||
|
||||
adTa5kEquipmentRedundancySwitchToProtectClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This alarm indicates that the 'working' module has now become active.
|
||||
This alarm is only generated when revertive mode is enabled. The 'working' module is always the left-most module (odd slot).
|
||||
The 'protect' module is always the right-most module (even slot)."
|
||||
|
||||
--#TYPE "Status - Eqpt APS On Clear"
|
||||
--#SUMMARY "Redundancy: Eqpt APS On Clear"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d"
|
||||
--#ARGUMENTS {1, 2}
|
||||
--#SEVERITY WARNING
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 12 }
|
||||
|
||||
adTa5kEquipmentRedundancySwitchToProtect NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This alarm indicates that the 'working' module has failed and the 'protect' module is now active.
|
||||
This alarm is only generated when revertive mode is enabled. The 'working' module is always the left-most module (odd slot).
|
||||
The 'protect' module is always the right-most module (even slot)."
|
||||
|
||||
--#TYPE "Status - Eqpt APS On"
|
||||
--#SUMMARY "Redundancy: Eqpt APS On"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d"
|
||||
--#ARGUMENTS {1, 2}
|
||||
--#SEVERITY WARNING
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 13 }
|
||||
|
||||
adTa5kRedundancyAutomaticSwitch NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the equipment initiated an automatic protection switch."
|
||||
|
||||
--#TYPE "Status - Automatic Switch"
|
||||
--#SUMMARY "Redundancy: Automatic Switch"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d"
|
||||
--#ARGUMENTS {1, 2}
|
||||
--#SEVERITY WARNING
|
||||
--#GENERIC 6
|
||||
--#CATEGORY "Error Events"
|
||||
--#SOURCE_ID "A"
|
||||
--#TIMEINDEX 0
|
||||
::= { adTa5kRedundancyAlarms 14 }
|
||||
|
||||
END
|
||||
|
||||
|
Reference in New Issue
Block a user