ADTRAN-GENSLOT-SUB-MODULE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- TITLE: Generic chassis slot sub module MIB (SMIv2)
|
||||
-- PRODUCT: All chassis type products
|
||||
-- VERSION: 1.0
|
||||
-- DATE: Jan. 17, 2011
|
||||
-- AUTHOR: Albert Sue
|
||||
-- SNMP: SNMPv2
|
||||
-- STATUS: PRELIMINARY
|
||||
|
||||
-- HISTORY:
|
||||
-- 01/17/11 A S: Created
|
||||
-- 02/28/11 A S: added "adFactGenSubSlotSwVersion" and "adFactGenSubSlotDateOfManufacturing"
|
||||
|
||||
IMPORTS
|
||||
OBJECT-TYPE,
|
||||
MODULE-IDENTITY,
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
|
||||
DisplayString,
|
||||
PhysAddress FROM SNMPv2-TC
|
||||
|
||||
sysName FROM SNMPv2-MIB
|
||||
|
||||
AdProductIdentifier FROM ADTRAN-TC
|
||||
|
||||
adGenSlot,
|
||||
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB;
|
||||
|
||||
|
||||
-- Slot Sub Module Group
|
||||
adGenSubSlotModule MODULE-IDENTITY
|
||||
LAST-UPDATED "201102280000Z"
|
||||
ORGANIZATION "ADTRAN, Inc."
|
||||
CONTACT-INFO
|
||||
" Technical Support Dept.
|
||||
Postal: ADTRAN, Inc.
|
||||
901 Explorer Blvd.
|
||||
Huntsville, AL 35806
|
||||
|
||||
Tel: +1 800 726-8663
|
||||
Fax: +1 256 963 6217
|
||||
E-mail: support@adtran.com"
|
||||
DESCRIPTION
|
||||
"The MIB module that describes the generic objects
|
||||
used to mananage individual cards in a shelf/bank
|
||||
developed by ADTRAN, Inc."
|
||||
::= { adGenSlot 7 }
|
||||
|
||||
--
|
||||
-- Product Information group for Sub Modules
|
||||
--
|
||||
-- This group contains information common for most all Adtran
|
||||
-- products. It is a slot addressable copy of the multi-scoped
|
||||
-- ADTRAN-MIB. It augments the slot info table.
|
||||
--
|
||||
|
||||
adGenSubSlotProdTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenSubSlotProdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table of slots available for boards."
|
||||
::= { adGenSlot 8 }
|
||||
|
||||
adGenSubSlotProdEntry OBJECT-TYPE
|
||||
SYNTAX AdGenSubSlotProdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
INDEX { adGenSlotInfoIndex, adGenSubSlotProdInfoIndex }
|
||||
::= { adGenSubSlotProdTable 1 }
|
||||
|
||||
AdGenSubSlotProdEntry ::=
|
||||
SEQUENCE {
|
||||
adGenSubSlotProdInfoIndex Integer32,
|
||||
adGenSubSlotProdName DisplayString,
|
||||
adGenSubSlotProdPartNumber DisplayString,
|
||||
adGenSubSlotProdCLEIcode DisplayString,
|
||||
adGenSubSlotProdSerialNumber DisplayString,
|
||||
adGenSubSlotProdRevision DisplayString,
|
||||
adGenSubSlotProdSwVersion DisplayString,
|
||||
adGenSubSlotProdDateOfManufacturing DisplayString
|
||||
}
|
||||
|
||||
adGenSubSlotProdInfoIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value for each slot's sub module."
|
||||
::= { adGenSubSlotProdEntry 1 }
|
||||
|
||||
adGenSubSlotProdName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product Name for the sub module"
|
||||
::= { adGenSubSlotProdEntry 2 }
|
||||
|
||||
adGenSubSlotProdPartNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product Part Number for the sub module"
|
||||
::= { adGenSubSlotProdEntry 3 }
|
||||
|
||||
adGenSubSlotProdCLEIcode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product CLEI Code for the sub module"
|
||||
::= { adGenSubSlotProdEntry 4 }
|
||||
|
||||
adGenSubSlotProdSerialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product Serial Number for the sub module"
|
||||
::= { adGenSubSlotProdEntry 5 }
|
||||
|
||||
adGenSubSlotProdRevision OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product Revision Number for the sub module"
|
||||
::= { adGenSubSlotProdEntry 6 }
|
||||
|
||||
adGenSubSlotProdSwVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Product Software Version Number for the sub module"
|
||||
::= { adGenSubSlotProdEntry 7 }
|
||||
|
||||
adGenSubSlotProdDateOfManufacturing OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Adtran Date of Manufacturing for the sub module."
|
||||
::= { adGenSubSlotProdEntry 8 }
|
||||
|
||||