ADTRAN-GENMEVC-MIB
|
||||
|
||||
-- TITLE: The ADTRAN MEVC MIB
|
||||
-- PRODUCT: Metro Ethernet Products
|
||||
-- VERSION: 1.0
|
||||
-- DATE: 07/21/10
|
||||
-- AUTHOR: Anil Shah
|
||||
-- STATUS: PRELIMINARY
|
||||
|
||||
-- This MIB defines the object identifiers (OIDs) for the
|
||||
-- ADTRAN GENMEVC MIB objects
|
||||
|
||||
-- HISTORY:
|
||||
-- 2010/06/17 ams STATUS: PRELIMINARY.
|
||||
-- 2010/07/21 ams Added a New table to report MEVC creation error. Added MEVC name as
|
||||
-- a second index to report MEN Port creation error on MEVC. Added a
|
||||
-- new table to display number of MEVCs on SLOT.
|
||||
-- 2011/02/16 ams Added VLAN in use table.
|
||||
--
|
||||
-- *** DO NOT USE THIS FIELD. ***
|
||||
-- ******************************************************************************************
|
||||
DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
|
||||
adGenMEVC,
|
||||
adGenMEVCID FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
||||
|
||||
OBJECT-TYPE,
|
||||
MODULE-IDENTITY,
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
|
||||
DisplayString,
|
||||
RowStatus,
|
||||
TimeStamp FROM SNMPv2-TC
|
||||
|
||||
ifIndex,
|
||||
InterfaceIndex FROM IF-MIB
|
||||
|
||||
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
|
||||
|
||||
;
|
||||
|
||||
adGenMEVCMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201501120000Z"
|
||||
ORGANIZATION "Adtran, Inc."
|
||||
CONTACT-INFO
|
||||
"CND Tech Support
|
||||
Postal: ADTRAN, Inc.
|
||||
901 Explorer Blvd.
|
||||
Huntsville, AL 35806
|
||||
Tel: +1 800 726-8663
|
||||
Fax: +1 256 963 6217
|
||||
E-mail: support@adtran.com"
|
||||
DESCRIPTION
|
||||
"This MIB defines the objects for the MEVC MIB."
|
||||
|
||||
REVISION "201501120000Z"
|
||||
DESCRIPTION "Added adGenMEVCIGMPImmediateLeave, adGenMEVCIGMPTimeoutInterval and adGenMEVCIGMPMode in the adGenMEVCTable
|
||||
Added a New adGenMEVCIGMPTable table."
|
||||
|
||||
REVISION "201307030000Z"
|
||||
DESCRIPTION "Added a adGenMEVCEnhMenPortTable to replace adGenMEVCMenPortTable.
|
||||
This new table accepts interfaces from multiple slots to be added to MEVC."
|
||||
|
||||
REVISION "201108260000Z"
|
||||
DESCRIPTION "Added Management Entry to MEVC Table."
|
||||
REVISION "201102160000Z"
|
||||
DESCRIPTION "Created"
|
||||
|
||||
::= { adGenMEVCID 1 }
|
||||
|
||||
adGenMEVCEvents OBJECT IDENTIFIER ::= {adGenMEVC 0}
|
||||
adGenMEVCProvisioning OBJECT IDENTIFIER ::= {adGenMEVC 1}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC provisioning table."
|
||||
::= { adGenMEVCProvisioning 1 }
|
||||
|
||||
adGenMEVCEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC provisioning table. MEVC entries
|
||||
are uniquely identified on Slot as well as by the MEvc
|
||||
Name."
|
||||
INDEX { adGenSlotInfoIndex, IMPLIED adGenMEVCName }
|
||||
::= { adGenMEVCTable 1 }
|
||||
|
||||
AdGenMEVCEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCName
|
||||
DisplayString,
|
||||
adGenMEVCRowStatus
|
||||
RowStatus,
|
||||
adGenMEVCOperStatus
|
||||
INTEGER,
|
||||
adGenMEVCStatus
|
||||
DisplayString,
|
||||
adGenMEVCSTagVID
|
||||
Integer32,
|
||||
adGenMEVCPreserveCEVlanId
|
||||
INTEGER,
|
||||
adGenMEVCMacSwitching
|
||||
INTEGER,
|
||||
adGenMEVCNumberOfInterfaces
|
||||
Integer32,
|
||||
adGenMEVCLastError
|
||||
DisplayString,
|
||||
adGenMevcManagement
|
||||
INTEGER,
|
||||
adGenMEVCIGMPImmediateLeave
|
||||
INTEGER,
|
||||
adGenMEVCIGMPTimeOutInterval
|
||||
INTEGER,
|
||||
adGenMEVCIGMPMode
|
||||
INTEGER
|
||||
}
|
||||
|
||||
adGenMEVCName OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (1..50))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A user configurable name for the MEVC. Upon creation of the MEVC,
|
||||
the associated name will default to a unique value."
|
||||
::= { adGenMEVCEntry 1}
|
||||
|
||||
adGenMEVCRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to create a new row or modify or delete an
|
||||
existing row in the MEVC table."
|
||||
::= { adGenMEVCEntry 2}
|
||||
|
||||
adGenMEVCOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
up(1),
|
||||
down(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the current operational status of the MEVC."
|
||||
::= { adGenMEVCEntry 3}
|
||||
|
||||
adGenMEVCStatus OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable provides the MEVC status. If there is no error, the MEVC
|
||||
status will be 'running'. If there is an error and the MEVC cannot be
|
||||
applied, then adGenMEVCStatus will provide more details about the error."
|
||||
::= { adGenMEVCEntry 4}
|
||||
|
||||
adGenMEVCSTagVID OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable specifies the outermost VLAN S-Tag VID for
|
||||
frames on this MEVC. No two entries in the MEVC Table may
|
||||
have the same S-Tag VID.
|
||||
S-Tag values 0 and 4095 are reserved and should not be used.
|
||||
Set the S-Tag to 4096 for untagged traffic and to 4097 for
|
||||
priority tagged traffic."
|
||||
::= { adGenMEVCEntry 5}
|
||||
|
||||
adGenMEVCPreserveCEVlanId OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(1),
|
||||
enabled(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This option provisions whether to preserve the CE VLAN tag
|
||||
received at the UNI port. Select enabled to push the MEVC tag
|
||||
onto the CE tag for frames destined for this MEVC. Select
|
||||
disabled to remove the CE VLAN tag and to add the MEVC tag
|
||||
for the frames destined for this MEVC."
|
||||
::= { adGenMEVCEntry 6}
|
||||
|
||||
adGenMEVCMacSwitching OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(1),
|
||||
enabled(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This option provisions whether MAC Switching should be
|
||||
performed on this MEVC."
|
||||
::= { adGenMEVCEntry 7}
|
||||
|
||||
adGenMEVCNumberOfInterfaces OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the number of interfaces connected to this MEVC."
|
||||
::= {adGenMEVCEntry 8}
|
||||
|
||||
adGenMEVCLastError OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This string describes the last error experienced
|
||||
for this particular entry in the table."
|
||||
::= { adGenMEVCEntry 9 }
|
||||
|
||||
adGenMevcManagement OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disable(1),
|
||||
local(2),
|
||||
system(3)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This option provisions management vlan traffic
|
||||
switching setting.
|
||||
Disable - Only non-management Vlan traffic switching.
|
||||
Local - Management Vlan traffic switched locally.
|
||||
System - Management Vlan traffic switched through the system."
|
||||
::= { adGenMEVCEntry 10 }
|
||||
|
||||
adGenMEVCIGMPImmediateLeave OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(1),
|
||||
enabled(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable/Disable immediate leave. "
|
||||
DEFVAL { disabled }
|
||||
::= { adGenMEVCEntry 11 }
|
||||
|
||||
adGenMEVCIGMPTimeOutInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..65535)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IGMP group membership interval in units of seconds.
|
||||
If no IGMP join is received for a video group before this
|
||||
interval expires, then the video group is removed for
|
||||
the host interface."
|
||||
DEFVAL { 260 }
|
||||
::= { adGenMEVCEntry 12 }
|
||||
|
||||
adGenMEVCIGMPMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
transparent(1),
|
||||
snooping(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The IGMP Mode associated with this MEVC ."
|
||||
DEFVAL { transparent }
|
||||
::= { adGenMEVCEntry 13}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCLookupTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCLookupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC lookup table."
|
||||
::= { adGenMEVCProvisioning 2 }
|
||||
|
||||
adGenMEVCLookupEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCLookupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC lookup table. This table has one
|
||||
entry for each row in the adGenMEVCTable. This table is
|
||||
used to find the MEVC name for a given SLOT and S-Tag
|
||||
VLAN Id."
|
||||
INDEX { adGenSlotInfoIndex, adGenMEVCLookupSTag }
|
||||
::= { adGenMEVCLookupTable 1 }
|
||||
|
||||
AdGenMEVCLookupEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCLookupSTag
|
||||
Integer32,
|
||||
adGenMEVCLookupName
|
||||
DisplayString
|
||||
}
|
||||
|
||||
adGenMEVCLookupSTag OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The S-Tag VLAN Id.
|
||||
S-Tag values 0, 1, and 4095 are reserved and should not be used.
|
||||
Set the S-Tag to 4096 for untagged traffic and to 4097 for
|
||||
priority tagged traffic."
|
||||
::= { adGenMEVCLookupEntry 1}
|
||||
|
||||
adGenMEVCLookupName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns the MEVC name associated with the given S-Tag VID."
|
||||
::= { adGenMEVCLookupEntry 2}
|
||||
|
||||
--==================================================================================================================
|
||||
adGenMEVCErrorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCErrorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC Creation Error table."
|
||||
::= { adGenMEVCProvisioning 3 }
|
||||
|
||||
adGenMEVCErrorEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCErrorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC Creation Error table.
|
||||
The index, adGenSlotInfoIndex, identifies the SLOT."
|
||||
INDEX { adGenSlotInfoIndex}
|
||||
::= { adGenMEVCErrorTable 1 }
|
||||
|
||||
AdGenMEVCErrorEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCError
|
||||
DisplayString
|
||||
}
|
||||
|
||||
adGenMEVCError OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns information about the last error for the MEVC
|
||||
create on SLOT. If row creation fails, this string
|
||||
will provide details about why the row could not be created."
|
||||
::= { adGenMEVCErrorEntry 1}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCMenPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCMenPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The MEVC MEN Port table.
|
||||
|
||||
NOTE: This table has been deprecated and replaced by
|
||||
the adGenMEVCEnhMenPortTable. The OIDs within
|
||||
this table always assume slot and port identified
|
||||
via ifIndex."
|
||||
::= { adGenMEVCProvisioning 4 }
|
||||
|
||||
adGenMEVCMenPortEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCMenPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC MEN Port table. This table can be
|
||||
used to add or remove MEN Port connections for an MEVC.
|
||||
The first index, ifIndex, identifies the MEN port.
|
||||
The second index, adGenProvisionedMEVCName, identifies the MEVC.
|
||||
|
||||
NOTE: This table has been deprecated and replaced by
|
||||
the adGenMEVCEnhMenPortTable. The OIDs within
|
||||
this table always assume slot and port identified
|
||||
via ifIndex."
|
||||
INDEX { ifIndex, adGenProvisionedMEVCName }
|
||||
::= { adGenMEVCMenPortTable 1 }
|
||||
|
||||
AdGenMEVCMenPortEntry ::=
|
||||
SEQUENCE {
|
||||
adGenProvisionedMEVCName
|
||||
OCTET STRING,
|
||||
adGenMEVCMenPortRowStatus
|
||||
RowStatus,
|
||||
adGenMEVCMenPortConnectionType
|
||||
INTEGER
|
||||
}
|
||||
|
||||
adGenProvisionedMEVCName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..50))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A user configurable name for the MEVC. Upon creation of the MEVC,
|
||||
the associated name will default to a unique value.
|
||||
|
||||
NOTE: This table has been deprecated and replaced by
|
||||
the adGenMEVCEnhMenPortTable. The OIDs within
|
||||
this table always assume slot and port identified
|
||||
via ifIndex."
|
||||
::= { adGenMEVCMenPortEntry 1}
|
||||
|
||||
adGenMEVCMenPortRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This object is used to create or destroy a MEN Port
|
||||
connection for an MEVC.
|
||||
|
||||
NOTE: This table has been deprecated and replaced by
|
||||
the adGenMEVCEnhMenPortTable. The OIDs within
|
||||
this table always assume slot and port identified
|
||||
via ifIndex."
|
||||
::= { adGenMEVCMenPortEntry 2}
|
||||
|
||||
adGenMEVCMenPortConnectionType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
root(1),
|
||||
leaf(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This option provisions whether the MEN port is a root
|
||||
or leaf of the given MEVC.
|
||||
|
||||
NOTE: This table has been deprecated and replaced by
|
||||
the adGenMEVCEnhMenPortTable. The OIDs within
|
||||
this table always assume slot and port identified
|
||||
via ifIndex."
|
||||
DEFVAL { root }
|
||||
::= { adGenMEVCMenPortEntry 3}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCMenPortConnectionErrorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCMenPortConnectionErrorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC MEN Port Connection Error table."
|
||||
::= { adGenMEVCProvisioning 5 }
|
||||
|
||||
adGenMEVCMenPortConnectionErrorEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCMenPortConnectionErrorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC MEN Port Connection Error table.
|
||||
The first index, adGenSlotInfoIndex, identifies the SLOT.
|
||||
The second index, adGenProvisionedMenPortMEVCName, identifies the MEVC"
|
||||
INDEX { adGenSlotInfoIndex, adGenProvisionedMenPortMEVCName}
|
||||
::= { adGenMEVCMenPortConnectionErrorTable 1 }
|
||||
|
||||
AdGenMEVCMenPortConnectionErrorEntry ::=
|
||||
SEQUENCE {
|
||||
adGenProvisionedMenPortMEVCName
|
||||
OCTET STRING,
|
||||
adGenMEVCMenPortConnectionError
|
||||
DisplayString
|
||||
}
|
||||
|
||||
adGenProvisionedMenPortMEVCName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..50))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A user configured name for the MEVC."
|
||||
::= { adGenMEVCMenPortConnectionErrorEntry 1}
|
||||
|
||||
adGenMEVCMenPortConnectionError OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns information about the last error for the MEVC
|
||||
MEN Port table on SLOT. If row creation fails, this string
|
||||
will provide details about why the row could not be created."
|
||||
::= { adGenMEVCMenPortConnectionErrorEntry 2}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCMenPortProvisioningTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCMenPortProvisioningEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC MEN Port Provisioning table."
|
||||
::= { adGenMEVCProvisioning 6 }
|
||||
|
||||
adGenMEVCMenPortProvisioningEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCMenPortProvisioningEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC MEN Port Provisioning table.
|
||||
This table can be used to provision a MEN port. The
|
||||
index for this table is the ifIndex of the MEN port."
|
||||
INDEX { ifIndex }
|
||||
::= { adGenMEVCMenPortProvisioningTable 1 }
|
||||
|
||||
AdGenMEVCMenPortProvisioningEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCMenPortStagDei
|
||||
INTEGER
|
||||
}
|
||||
|
||||
adGenMEVCMenPortStagDei OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled (1),
|
||||
enabled (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This option provisions the marking of the DEI bit.
|
||||
When enabled, the bit functions as the Drop Eligible Indicator.
|
||||
When disabled, the bit functions as the Canonical Format Indicator."
|
||||
::= { adGenMEVCMenPortProvisioningEntry 1 }
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCNumberOfMEVCsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCNumberOfMEVCsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC table to display number Of MEVCs associated with the Slot."
|
||||
::= { adGenMEVCProvisioning 7 }
|
||||
|
||||
adGenMEVCNumberOfMEVCsEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCNumberOfMEVCsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC Number of MEVCs table.
|
||||
The index, adGenSlotInfoIndex, identifies the SLOT."
|
||||
INDEX { adGenSlotInfoIndex }
|
||||
::= { adGenMEVCNumberOfMEVCsTable 1 }
|
||||
|
||||
AdGenMEVCNumberOfMEVCsEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCNumberOfMEVCs
|
||||
Integer32
|
||||
}
|
||||
|
||||
adGenMEVCNumberOfMEVCs OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable is used to display number of MEVCs associated
|
||||
with the Slot."
|
||||
::= { adGenMEVCNumberOfMEVCsEntry 1}
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenVLANInUseLookupTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenVLANInUseLookupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The VLAN In Use lookup table."
|
||||
::= { adGenMEVCProvisioning 8 }
|
||||
|
||||
adGenVLANInUseLookupEntry OBJECT-TYPE
|
||||
SYNTAX AdGenVLANInUseLookupEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the VLAN In Use lookup table. This table is use to
|
||||
determine which VLANs are in use on specific SLOT."
|
||||
INDEX { adGenSlotInfoIndex }
|
||||
::= { adGenVLANInUseLookupTable 1 }
|
||||
|
||||
AdGenVLANInUseLookupEntry ::=
|
||||
SEQUENCE {
|
||||
adGenVLANInUseLookupData
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
adGenVLANInUseLookupData OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(512))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A binary string is returned, where each VLAN is represented
|
||||
as a - bit, where 1 is in use, 0 is not in use. This applies
|
||||
for all 4096 VLANs. Following is how VLANs are represented in
|
||||
Octet string:
|
||||
VLAN 0 - Octet byte 1, bit 7(MSB)
|
||||
VLAN 1 - Octet byte 1, bit 6
|
||||
VLAN 2 - Octet byte 1, bit 5
|
||||
....
|
||||
VLAN 7 - Octet byte 1, bit 0(LSB)
|
||||
VLAN 8 - Octet byte 2, bit 7(MSB)
|
||||
....
|
||||
VLAN 4095 - Octet byte 512, bit 0(LSB)"
|
||||
::= { adGenVLANInUseLookupEntry 1 }
|
||||
|
||||
--==================================================================================================================
|
||||
|
||||
adGenMEVCEnhMenPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCEnhMenPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MEVC MEN Port table."
|
||||
::= { adGenMEVCProvisioning 9 }
|
||||
|
||||
adGenMEVCEnhMenPortEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCEnhMenPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC MEN Port table. This table can be
|
||||
used to add or remove MEN Port connections for an MEVC.
|
||||
The first index, identifies slot number associated with MEVC name.
|
||||
The second index, adGenMEVCMenPortIfIndex, identifies the MEN port.
|
||||
The third index, adGenProvMEVCName, identifies the MEVC"
|
||||
INDEX { adGenSlotInfoIndex, adGenMEVCMenPortIfIndex, adGenProvMEVCName }
|
||||
::= { adGenMEVCEnhMenPortTable 1 }
|
||||
|
||||
AdGenMEVCEnhMenPortEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCMenPortIfIndex
|
||||
InterfaceIndex,
|
||||
adGenProvMEVCName
|
||||
OCTET STRING,
|
||||
adGenMEVCEnhMenPortRowStatus
|
||||
RowStatus,
|
||||
adGenMEVCEnhMenPortConnectionType
|
||||
INTEGER
|
||||
}
|
||||
|
||||
adGenMEVCMenPortIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This interface index of the MEN port to be connected to this EVC."
|
||||
::= { adGenMEVCEnhMenPortEntry 1}
|
||||
|
||||
adGenProvMEVCName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..50))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A user configurable name for the MEVC. Upon creation of the MEVC,
|
||||
the associated name will default to a unique value."
|
||||
::= { adGenMEVCEnhMenPortEntry 2}
|
||||
|
||||
adGenMEVCEnhMenPortRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to create or destroy a MEN Port
|
||||
connection for an MEVC."
|
||||
::= { adGenMEVCEnhMenPortEntry 3}
|
||||
|
||||
adGenMEVCEnhMenPortConnectionType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
root(1),
|
||||
leaf(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This option provisions whether the MEN port is a root
|
||||
or leaf of the given MEVC."
|
||||
DEFVAL { root }
|
||||
::= { adGenMEVCEnhMenPortEntry 4}
|
||||
|
||||
--==================================================================================================================
|
||||
adGenMEVCIGMPTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenMEVCIGMPEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The MEVC IGMP table."
|
||||
::= { adGenMEVCProvisioning 10}
|
||||
|
||||
adGenMEVCIGMPEntry OBJECT-TYPE
|
||||
SYNTAX AdGenMEVCIGMPEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the MEVC IGMP table. This table can be
|
||||
used to enable or disable the interface mode to either
|
||||
of the igmp host or router . The first index, identifies
|
||||
slot number associated with the mevc name. The second index,
|
||||
adGenMEVCIGMPInterfaceIndex, identifies the port. Third index,
|
||||
adGenMEVCName identifies the mevc name."
|
||||
INDEX { adGenSlotInfoIndex, adGenMEVCIGMPInterfaceIndex, adGenMEVCIGMPEVCName }
|
||||
::= { adGenMEVCIGMPTable 1 }
|
||||
|
||||
|
||||
AdGenMEVCIGMPEntry ::=
|
||||
SEQUENCE {
|
||||
adGenMEVCIGMPInterfaceIndex InterfaceIndex,
|
||||
adGenMEVCIGMPEVCName OCTET STRING,
|
||||
adGenMEVCIGMPInterfaceMode INTEGER,
|
||||
adGenMEVCIGMPRowStatus RowStatus,
|
||||
adGenMEVCIGMPLastError DisplayString
|
||||
}
|
||||
|
||||
adGenMEVCIGMPInterfaceIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This interface index of the port on which IGMP mode is configured."
|
||||
::= { adGenMEVCIGMPEntry 1}
|
||||
|
||||
adGenMEVCIGMPEVCName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..50))
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A user configurable name for the MEVC. Upon creation of the MEVC,
|
||||
the associated name will default to a unique value."
|
||||
::= { adGenMEVCIGMPEntry 2}
|
||||
|
||||
adGenMEVCIGMPInterfaceMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
host(1),
|
||||
router(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"host - RFC2236 host facing interface. Enable the interface act as IGMP host.
|
||||
router - RFC2236 Router facing interface. Enable the interface act as IGMP router."
|
||||
DEFVAL { host }
|
||||
::= { adGenMEVCIGMPEntry 3}
|
||||
|
||||
adGenMEVCIGMPRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to create or modify or destroy a IGMP mode
|
||||
on interface for an MEVC."
|
||||
::= { adGenMEVCIGMPEntry 4}
|
||||
|
||||
adGenMEVCIGMPLastError OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns information about the last error for the MEVC
|
||||
IGMP table on slot. If row creation fails, this string
|
||||
will provide details about why the row could not be created."
|
||||
::= { adGenMEVCIGMPEntry 5 }
|
||||
|
||||
END
|
||||
|
||||
|
Reference in New Issue
Block a user