Commit version 24.12.13800
This commit is contained in:
539
mibs/adtran/ADTRAN-GENIF-MIB
Normal file
539
mibs/adtran/ADTRAN-GENIF-MIB
Normal file
@ -0,0 +1,539 @@
|
||||
ADTRAN-GENIF-MIB
|
||||
|
||||
-- TITLE: The ADTRAN GENIF MIB
|
||||
-- PRODUCT: ADTRAN PRODUCTS
|
||||
-- VERSION: 1.0
|
||||
-- DATE: 11/17/2008
|
||||
-- AUTHOR: Chip Gusler
|
||||
-- STATUS: PRELIMINARY
|
||||
|
||||
-- This MIB defines the object identifier (OID) for the
|
||||
-- ADTRAN-GENIF-MIB objects. This will is a supplement to the existing
|
||||
-- IF-MIB. It is intended to provide Adtran generic extensions on a
|
||||
-- per-interface basis.
|
||||
|
||||
-- HISTORY:
|
||||
-- 11/17/08 ltg Created
|
||||
-- 06/15/09 glf Modified to add Auto In Service Feature
|
||||
-- 07/09/09 glf Modified to add new OID adGenIfAutoInServiceTimeOutCounter and to
|
||||
-- change enums to adGenIfAutoInServiceStatus
|
||||
-- 09/22/09 srao Added traps for interface service state OOS-MA active/clear and an OID for enabling/disabling this alarm.
|
||||
-- 10/28/09 srao Interchanged the values of enable/disable of the OID adGenIfServiceStateOOSMAAlarmEnable
|
||||
-- 02/28/11 twc Deprecated adGenIfResetCounters, added adGenIfResetAllPM and adGenIfResetAllCounters
|
||||
-- ******************************************************************************************
|
||||
|
||||
DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32,Counter64,Gauge32,Counter32,
|
||||
NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
sysName
|
||||
FROM SNMPv2-MIB
|
||||
ifIndex, ifDescr, ifAdminStatus FROM IF-MIB
|
||||
TruthValue FROM SNMPv2-TC
|
||||
adGenIf, adGenIfID
|
||||
FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
||||
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
|
||||
adTrapInformSeqNum
|
||||
FROM ADTRAN-GENTRAPINFORM-MIB
|
||||
;
|
||||
|
||||
adGenIfMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201305310000Z"
|
||||
ORGANIZATION "Adtran, Inc."
|
||||
CONTACT-INFO "http://www.adtran.com"
|
||||
DESCRIPTION
|
||||
"Adtran enterprise generic IF-MIB extensions."
|
||||
|
||||
REVISION "201305310000Z"
|
||||
DESCRIPTION "Obsolete the Port OOS-MA alarm and the associated enable/disable provisioning."
|
||||
|
||||
REVISION "201112160000Z"
|
||||
DESCRIPTION "Added discards to 15 minute and 24 hour PM"
|
||||
|
||||
REVISION "201112060000Z"
|
||||
DESCRIPTION "Multicast, unicast and broadcast counter OIDs"
|
||||
|
||||
REVISION "201102280000Z"
|
||||
DESCRIPTION "New generic reset PM and reset counter OIDs"
|
||||
|
||||
REVISION "200811170000Z"
|
||||
DESCRIPTION "Created"
|
||||
::= { adGenIfID 1 }
|
||||
|
||||
-- OBJECT IDENTIFIERS
|
||||
adGenIfMIBObjects OBJECT IDENTIFIER ::= {adGenIf 1}
|
||||
|
||||
|
||||
-- ******************************************************************************************
|
||||
-- adGenIfTable
|
||||
-- ******************************************************************************************
|
||||
|
||||
adGenIfTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenIfEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table supports Adtran per-interface IF-MIB extensions.
|
||||
The number of entries is given by the value of ifNumber."
|
||||
::= { adGenIfMIBObjects 1 }
|
||||
|
||||
|
||||
adGenIfEntry OBJECT-TYPE
|
||||
SYNTAX AdGenIfEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing Adtran specific control/information applicable
|
||||
to the indexed interface."
|
||||
INDEX { ifIndex }
|
||||
::= { adGenIfTable 1 }
|
||||
|
||||
|
||||
AdGenIfEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
adGenIfResetCounters INTEGER, -- deprecated
|
||||
adGenIfAutoInServiceEnable TruthValue,
|
||||
adGenIfAutoInServiceTimeOut INTEGER,
|
||||
adGenIfAutoInServiceTimeOutCounter Integer32,
|
||||
adGenIfAutoInServiceStatus INTEGER,
|
||||
adGenIfServiceStateOOSMAAlarmEnable INTEGER,
|
||||
adGenIfResetAllCounters INTEGER,
|
||||
adGenIfResetAllPM INTEGER,
|
||||
adGenIfInUnicastOctets Counter64,
|
||||
adGenIfOutUnicastOctets Counter64,
|
||||
adGenIfInBroadcastOctets Counter64,
|
||||
adGenIfOutBroadcastOctets Counter64,
|
||||
adGenIfOutDiscardedOctets Counter64,
|
||||
adGenIfInMulticastOctets Counter64,
|
||||
adGenIfOutMulticastOctets Counter64,
|
||||
adGenIfInFrames Counter64,
|
||||
adGenIfOutFrames Counter64
|
||||
}
|
||||
|
||||
|
||||
adGenIfResetCounters OBJECT-TYPE -- deprecated
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
all(1), -- Reset both PM history and current counters
|
||||
pmhistory(2), -- Reset PM history counters
|
||||
current(3) -- Reset current counters
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This object is deprecated due to confusion among users regarding its intended
|
||||
purpose. Two new objects (adGenIfResetAllPM and adGenIfResetAllCounters) should
|
||||
be used instead. The original description text is below:
|
||||
Selection of counter types to reset/clear for the indexed interface.
|
||||
The counter types are performance monitoring intervals (PM history)
|
||||
which typically consist of 15 minute/24 hour interval data,
|
||||
and current counters. A read will always return all(1)."
|
||||
::= { adGenIfEntry 1 }
|
||||
|
||||
adGenIfAutoInServiceEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Set to true to enable and false to disable auto in service on this interface."
|
||||
DEFVAL {false}
|
||||
::= { adGenIfEntry 2 }
|
||||
|
||||
adGenIfAutoInServiceTimeOut OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..9999)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Sets the timeout value in minutes "
|
||||
DEFVAL {480}
|
||||
::= { adGenIfEntry 3 }
|
||||
|
||||
adGenIfAutoInServiceTimeOutCounter OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Returns time remaining on the AINS timer "
|
||||
|
||||
::= { adGenIfEntry 4 }
|
||||
|
||||
adGenIfAutoInServiceStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
up(1), --Able to run traffic
|
||||
down(2), --Some defect (e.g. LOS, LOF) does not permit traffic to run
|
||||
testing(3), --BERT and/or loopback in progress
|
||||
oosAuAinsFaf(4),--Out of Service-Autonomous Automatic In Service with facility faults
|
||||
oosAuAins(5), --Out of Service-Autonomous Automatic In Service w/o facility faults
|
||||
oosAuAinsTs(6) --Out of Service-Autonomous Automatic In Service Testing
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The facility service state."
|
||||
|
||||
::= { adGenIfEntry 5 }
|
||||
|
||||
adGenIfServiceStateOOSMAAlarmEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"Enables/disables the interface service state OOS-MA alarm."
|
||||
::= { adGenIfEntry 6 }
|
||||
|
||||
adGenIfResetAllPM OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A SET causes all Performance Monitoring history for the selected interface to be reset to zero.
|
||||
This will reset all interval PM counts (15min and 24hr) as well as the current PM counts
|
||||
(15min and 24hr) for the selected interface. This object has NO affect on rolling counters.
|
||||
A GET will always return a one (1)."
|
||||
::= { adGenIfEntry 7 }
|
||||
|
||||
adGenIfResetAllCounters OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reset(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A SET causes all rolling counters for the selected interface to be reset to zero.
|
||||
This object has NO affect on PM. A GET will always return a one (1)."
|
||||
::= { adGenIfEntry 8 }
|
||||
|
||||
adGenIfInUnicastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of unicast octets received on the interface."
|
||||
::= { adGenIfEntry 9 }
|
||||
|
||||
adGenIfOutUnicastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of unicast octets transmitted on the interface."
|
||||
::= { adGenIfEntry 10 }
|
||||
|
||||
adGenIfInBroadcastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of broadcast octets received on the interface."
|
||||
::= { adGenIfEntry 11 }
|
||||
|
||||
adGenIfOutBroadcastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of broadcast octets transmitted on the interface."
|
||||
::= { adGenIfEntry 12 }
|
||||
|
||||
adGenIfInMulticastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of multicast octets received on the interface."
|
||||
::= { adGenIfEntry 13 }
|
||||
|
||||
adGenIfOutMulticastOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of multicast octets transmitted on the interface."
|
||||
::= { adGenIfEntry 14 }
|
||||
|
||||
adGenIfOutDiscardedOctets OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of Tx discarded octets on the interface."
|
||||
::= { adGenIfEntry 15 }
|
||||
|
||||
adGenIfInFrames OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of Rx frames on the interface."
|
||||
::= { adGenIfEntry 16 }
|
||||
|
||||
adGenIfOutFrames OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total number of Tx frames on the interface."
|
||||
::= { adGenIfEntry 17 }
|
||||
|
||||
-- *********************************************************************
|
||||
-- adGenIfCurr15MinPMTable
|
||||
-- *********************************************************************
|
||||
|
||||
adGenIfCurr15MinPMTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenIfCurr15MinPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table supports Adtran per-interface IF-MIB extensions
|
||||
for current 15-minute performance monitoring."
|
||||
::= { adGenIfMIBObjects 2 }
|
||||
|
||||
adGenIfCurr15MinPMEntry OBJECT-TYPE
|
||||
SYNTAX AdGenIfCurr15MinPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing Adtran specific control/information applicable
|
||||
to the indexed interface."
|
||||
INDEX { ifIndex }
|
||||
::= { adGenIfCurr15MinPMTable 1 }
|
||||
|
||||
AdGenIfCurr15MinPMEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
adGenIfCurr15MinPMOutDiscards Gauge32,
|
||||
adGenIfCurr15MinPMOutDiscardOctets Gauge32
|
||||
}
|
||||
|
||||
adGenIfCurr15MinPMOutDiscards OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of packets discarded on this interface during
|
||||
the current 15-minute interval."
|
||||
::= { adGenIfCurr15MinPMEntry 1 }
|
||||
|
||||
adGenIfCurr15MinPMOutDiscardOctets OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of octets discarded on this interface during
|
||||
the current 15-minute interval."
|
||||
::= { adGenIfCurr15MinPMEntry 2 }
|
||||
|
||||
-- *********************************************************************
|
||||
-- adGenIf15MinPMTable
|
||||
-- *********************************************************************
|
||||
|
||||
adGenIf15MinPMTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenIf15MinPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table supports Adtran per-interface IF-MIB extensions
|
||||
for 15 minute performance monitoring."
|
||||
::= { adGenIfMIBObjects 3 }
|
||||
|
||||
adGenIf15MinPMEntry OBJECT-TYPE
|
||||
SYNTAX AdGenIf15MinPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing Adtran specific control/information applicable
|
||||
to the indexed interface."
|
||||
INDEX { ifIndex, adGenIf15MinPMIntNumber }
|
||||
::= { adGenIf15MinPMTable 1 }
|
||||
|
||||
AdGenIf15MinPMEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
adGenIf15MinPMIntNumber Integer32,
|
||||
adGenIf15MinPMOutDiscards Gauge32,
|
||||
adGenIf15MinPMOutDiscardOctets Gauge32
|
||||
}
|
||||
|
||||
adGenIf15MinPMIntNumber OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"15-minute performance interval. Interval 1 represents the most recent
|
||||
previous interval. Interval 96 represents 24 hours ago. Intervals 2
|
||||
through 96 are optional."
|
||||
::= { adGenIf15MinPMEntry 1 }
|
||||
|
||||
adGenIf15MinPMOutDiscards OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of packets discarded on this interface during
|
||||
the selected 15-minute interval."
|
||||
::= { adGenIf15MinPMEntry 2 }
|
||||
|
||||
adGenIf15MinPMOutDiscardOctets OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of bytes discarded on this interface during
|
||||
the selected 15-minute interval."
|
||||
::= { adGenIf15MinPMEntry 3 }
|
||||
|
||||
-- *********************************************************************
|
||||
-- adGenIfCurr24HrPMTable
|
||||
-- *********************************************************************
|
||||
|
||||
adGenIfCurr24HrPMTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenIfCurr24HrPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table supports Adtran per-interface IF-MIB extensions
|
||||
for current 24 hour performance monitoring."
|
||||
::= { adGenIfMIBObjects 4 }
|
||||
|
||||
adGenIfCurr24HrPMEntry OBJECT-TYPE
|
||||
SYNTAX AdGenIfCurr24HrPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing Adtran specific control/information applicable
|
||||
to the indexed interface."
|
||||
INDEX { ifIndex }
|
||||
::= { adGenIfCurr24HrPMTable 1 }
|
||||
|
||||
AdGenIfCurr24HrPMEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
adGenIfCurr24HrPMOutDiscards Gauge32,
|
||||
adGenIfCurr24HrPMOutDiscardOctets Gauge32
|
||||
}
|
||||
|
||||
adGenIfCurr24HrPMOutDiscards OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of packets discarded on this interface during
|
||||
the current 24-hour interval."
|
||||
::= { adGenIfCurr24HrPMEntry 1 }
|
||||
|
||||
adGenIfCurr24HrPMOutDiscardOctets OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of octets discarded on this interface during
|
||||
the current 24-hour interval."
|
||||
::= { adGenIfCurr24HrPMEntry 2 }
|
||||
|
||||
-- *********************************************************************
|
||||
-- adGenIf24HrPMTable
|
||||
-- *********************************************************************
|
||||
|
||||
adGenIf24HrPMTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AdGenIf24HrPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table supports Adtran per-interface IF-MIB extensions
|
||||
for 24 hour performance monitoring."
|
||||
::= { adGenIfMIBObjects 5 }
|
||||
|
||||
adGenIf24HrPMEntry OBJECT-TYPE
|
||||
SYNTAX AdGenIf24HrPMEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry containing Adtran specific control/information applicable
|
||||
to the indexed interface."
|
||||
INDEX { ifIndex, adGenIf24HrPMIntNumber }
|
||||
::= { adGenIf24HrPMTable 1 }
|
||||
|
||||
AdGenIf24HrPMEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
adGenIf24HrPMIntNumber Integer32,
|
||||
adGenIf24HrPMOutDiscards Gauge32,
|
||||
adGenIf24HrPMOutDiscardOctets Gauge32
|
||||
}
|
||||
|
||||
adGenIf24HrPMIntNumber OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"24-hour performance interval. Interval 1 represents the most recent
|
||||
previous interval. Interval 30 represents 30 days ago. Intervals 2
|
||||
through 30 are optional."
|
||||
::= { adGenIf24HrPMEntry 1 }
|
||||
|
||||
adGenIf24HrPMOutDiscards OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of packets discarded on this interface during
|
||||
the selected 24-hour interval."
|
||||
::= { adGenIf24HrPMEntry 2 }
|
||||
|
||||
adGenIf24HrPMOutDiscardOctets OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of octets discarded on this interface during
|
||||
the selected 24-hour interval."
|
||||
::= { adGenIf24HrPMEntry 3 }
|
||||
|
||||
|
||||
-- ******************************************************************************************
|
||||
-- Alarms
|
||||
-- ******************************************************************************************
|
||||
adGenIfAlarms OBJECT IDENTIFIER ::= { adGenIf 0 }
|
||||
|
||||
adGenIfServiceStateOOSMAClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex,
|
||||
ifIndex,
|
||||
ifDescr
|
||||
}
|
||||
STATUS obsolete
|
||||
DESCRIPTION "Indicates Interface Service State is no longer OOS-MA"
|
||||
--#TYPE "Warning - Interface Service State OOS-MA Alarm Clear"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d, %s"
|
||||
--#SEVERITY WARNING
|
||||
--#ARGUMENTS {1,2,4}
|
||||
::= {adGenIfAlarms 1}
|
||||
|
||||
adGenIfServiceStateOOSMAActive NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
adTrapInformSeqNum,
|
||||
sysName,
|
||||
adGenSlotInfoIndex,
|
||||
ifIndex,
|
||||
ifDescr
|
||||
}
|
||||
STATUS obsolete
|
||||
DESCRIPTION "Indicates Interface Service State is currently OOS-MA"
|
||||
--#TYPE "Warning - Interface Service State OOS-MA Alarm Active"
|
||||
--#SUMMARY "Shelf: %s, Slot: %d, %s"
|
||||
--#SEVERITY WARNING
|
||||
--#ARGUMENTS {1,2,4}
|
||||
::= {adGenIfAlarms 2}
|
||||
END
|